authorJens Arnold <amiconn@rockbox.org>2007-08-17 06:45:18 +0000
committerJens Arnold <amiconn@rockbox.org>2007-08-17 06:45:18 +0000
commit0fac492c3da8b46ad1cf5a668e5d851c63443a94 (patch)
tree95fb6637601a4b3c730f4aec1d2e7e7ab78e208b /firmware/export/config-ipodmini.h
parent12706e4b1d4ce65df441dcf6e2b160657ea3fa38 (diff)
First step of powermanagement rework: * Move target specific stuff into target tree, starting with battery voltage tables and voltage reading. (This revealed some incorrect percent_to_voltage_charging mappings). * Voltage reading on 1st gen ipods is now correct. * Clean up obsolete config #defines.
git-svn-id: svn://svn.rockbox.org/rockbox/trunk@14375 a1c6a512-1295-4272-9138-f99709370657
Diffstat (limited to 'firmware/export/config-ipodmini.h')
-rw-r--r--firmware/export/config-ipodmini.h3
1 files changed, 0 insertions, 3 deletions
diff --git a/firmware/export/config-ipodmini.h b/firmware/export/config-ipodmini.h
index 3b215a43c5..54d0e2c230 100644
--- a/firmware/export/config-ipodmini.h
+++ b/firmware/export/config-ipodmini.h
@@ -78,14 +78,11 @@
/* Define this if you can detect headphones */
#define HAVE_HEADPHONE_DETECTION
-/* Type of mobile power */
-#define CONFIG_BATTERY BATT_LIPOL1300
#define BATTERY_CAPACITY_DEFAULT 400 /* default battery capacity */
#define BATTERY_CAPACITY_MIN 400 /* min. capacity selectable */
#define BATTERY_CAPACITY_MAX 800 /* max. capacity selectable */
#define BATTERY_CAPACITY_INC 10 /* capacity increment */
#define BATTERY_TYPES_COUNT 1 /* only one type */
-#define BATTERY_SCALE_FACTOR 5865
/* Hardware controlled charging? FIXME */
//#define CONFIG_CHARGING CHARGING_SIMPLE