diff options
Diffstat (limited to 'Documentation/devicetree/bindings/regulator/regulator.yaml')
-rw-r--r-- | Documentation/devicetree/bindings/regulator/regulator.yaml | 82 |
1 files changed, 82 insertions, 0 deletions
diff --git a/Documentation/devicetree/bindings/regulator/regulator.yaml b/Documentation/devicetree/bindings/regulator/regulator.yaml index 6d0bc9cd4040..a6ae9ecae5cc 100644 --- a/Documentation/devicetree/bindings/regulator/regulator.yaml +++ b/Documentation/devicetree/bindings/regulator/regulator.yaml @@ -117,6 +117,88 @@ properties: description: Enable over current protection. type: boolean + regulator-oc-protection-microamp: + description: Set over current protection limit. This is a limit where + hardware performs emergency shutdown. Zero can be passed to disable + protection and value '1' indicates that protection should be enabled but + limit setting can be omitted. + + regulator-oc-error-microamp: + description: Set over current error limit. This is a limit where part of + the hardware propably is malfunctional and damage prevention is requested. + Zero can be passed to disable error detection and value '1' indicates + that detection should be enabled but limit setting can be omitted. + + regulator-oc-warn-microamp: + description: Set over current warning limit. This is a limit where hardware + is assumed still to be functional but approaching limit where it gets + damaged. Recovery actions should be initiated. Zero can be passed to + disable detection and value '1' indicates that detection should + be enabled but limit setting can be omitted. + + regulator-ov-protection-microvolt: + description: Set over voltage protection limit. This is a limit where + hardware performs emergency shutdown. Zero can be passed to disable + protection and value '1' indicates that protection should be enabled but + limit setting can be omitted. Limit is given as microvolt offset from + voltage set to regulator. + + regulator-ov-error-microvolt: + description: Set over voltage error limit. This is a limit where part of + the hardware propably is malfunctional and damage prevention is requested + Zero can be passed to disable error detection and value '1' indicates + that detection should be enabled but limit setting can be omitted. Limit + is given as microvolt offset from voltage set to regulator. + + regulator-ov-warn-microvolt: + description: Set over voltage warning limit. This is a limit where hardware + is assumed still to be functional but approaching limit where it gets + damaged. Recovery actions should be initiated. Zero can be passed to + disable detection and value '1' indicates that detection should + be enabled but limit setting can be omitted. Limit is given as microvolt + offset from voltage set to regulator. + + regulator-uv-protection-microvolt: + description: Set over under voltage protection limit. This is a limit where + hardware performs emergency shutdown. Zero can be passed to disable + protection and value '1' indicates that protection should be enabled but + limit setting can be omitted. Limit is given as microvolt offset from + voltage set to regulator. + + regulator-uv-error-microvolt: + description: Set under voltage error limit. This is a limit where part of + the hardware propably is malfunctional and damage prevention is requested + Zero can be passed to disable error detection and value '1' indicates + that detection should be enabled but limit setting can be omitted. Limit + is given as microvolt offset from voltage set to regulator. + + regulator-uv-warn-microvolt: + description: Set over under voltage warning limit. This is a limit where + hardware is assumed still to be functional but approaching limit where + it gets damaged. Recovery actions should be initiated. Zero can be passed + to disable detection and value '1' indicates that detection should + be enabled but limit setting can be omitted. Limit is given as microvolt + offset from voltage set to regulator. + + regulator-temp-protection-kelvin: + description: Set over temperature protection limit. This is a limit where + hardware performs emergency shutdown. Zero can be passed to disable + protection and value '1' indicates that protection should be enabled but + limit setting can be omitted. + + regulator-temp-error-kelvin: + description: Set over temperature error limit. This is a limit where part of + the hardware propably is malfunctional and damage prevention is requested + Zero can be passed to disable error detection and value '1' indicates + that detection should be enabled but limit setting can be omitted. + + regulator-temp-warn-kelvin: + description: Set over temperature warning limit. This is a limit where + hardware is assumed still to be functional but approaching limit where it + gets damaged. Recovery actions should be initiated. Zero can be passed to + disable detection and value '1' indicates that detection should + be enabled but limit setting can be omitted. + regulator-active-discharge: description: | tristate, enable/disable active discharge of regulators. The values are: |