summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
-rw-r--r--MAINTAINERS1
-rw-r--r--drivers/media/cec/cec-edid.c2
-rw-r--r--drivers/media/cec/cec-notifier.c1
-rw-r--r--drivers/media/platform/s5p-cec/s5p_cec.c1
-rw-r--r--include/media/cec-edid.h133
-rw-r--r--include/media/cec-notifier.h2
-rw-r--r--include/media/cec.h102
7 files changed, 104 insertions, 138 deletions
diff --git a/MAINTAINERS b/MAINTAINERS
index cf0101544a08..84f185731b3c 100644
--- a/MAINTAINERS
+++ b/MAINTAINERS
@@ -3077,7 +3077,6 @@ F: Documentation/media/uapi/cec
F: drivers/media/cec/
F: drivers/media/rc/keymaps/rc-cec.c
F: include/media/cec.h
-F: include/media/cec-edid.h
F: include/media/cec-notifier.h
F: include/uapi/linux/cec.h
F: include/uapi/linux/cec-funcs.h
diff --git a/drivers/media/cec/cec-edid.c b/drivers/media/cec/cec-edid.c
index c63dc81d2a29..38e3fec6152b 100644
--- a/drivers/media/cec/cec-edid.c
+++ b/drivers/media/cec/cec-edid.c
@@ -20,7 +20,7 @@
#include <linux/module.h>
#include <linux/kernel.h>
#include <linux/types.h>
-#include <media/cec-edid.h>
+#include <media/cec.h>
/*
* This EDID is expected to be a CEA-861 compliant, which means that there are
diff --git a/drivers/media/cec/cec-notifier.c b/drivers/media/cec/cec-notifier.c
index 5f5209a73665..74dc1c32080e 100644
--- a/drivers/media/cec/cec-notifier.c
+++ b/drivers/media/cec/cec-notifier.c
@@ -24,6 +24,7 @@
#include <linux/list.h>
#include <linux/kref.h>
+#include <media/cec.h>
#include <media/cec-notifier.h>
#include <drm/drm_edid.h>
diff --git a/drivers/media/platform/s5p-cec/s5p_cec.c b/drivers/media/platform/s5p-cec/s5p_cec.c
index 4688f0879f55..664937b61fa4 100644
--- a/drivers/media/platform/s5p-cec/s5p_cec.c
+++ b/drivers/media/platform/s5p-cec/s5p_cec.c
@@ -25,7 +25,6 @@
#include <linux/timer.h>
#include <linux/workqueue.h>
#include <media/cec.h>
-#include <media/cec-edid.h>
#include <media/cec-notifier.h>
#include "exynos_hdmi_cec.h"
diff --git a/include/media/cec-edid.h b/include/media/cec-edid.h
deleted file mode 100644
index 242781fd377f..000000000000
--- a/include/media/cec-edid.h
+++ /dev/null
@@ -1,133 +0,0 @@
-/*
- * cec-edid - HDMI Consumer Electronics Control & EDID helpers
- *
- * Copyright 2016 Cisco Systems, Inc. and/or its affiliates. All rights reserved.
- *
- * This program is free software; you may redistribute it and/or modify
- * it under the terms of the GNU General Public License as published by
- * the Free Software Foundation; version 2 of the License.
- *
- * THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND,
- * EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF
- * MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND
- * NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS
- * BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN
- * ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN
- * CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE
- * SOFTWARE.
- */
-
-#ifndef _MEDIA_CEC_EDID_H
-#define _MEDIA_CEC_EDID_H
-
-#include <linux/types.h>
-
-#define CEC_PHYS_ADDR_INVALID 0xffff
-#define cec_phys_addr_exp(pa) \
- ((pa) >> 12), ((pa) >> 8) & 0xf, ((pa) >> 4) & 0xf, (pa) & 0xf
-
-#if IS_ENABLED(CONFIG_CEC_CORE)
-
-/**
- * cec_get_edid_phys_addr() - find and return the physical address
- *
- * @edid: pointer to the EDID data
- * @size: size in bytes of the EDID data
- * @offset: If not %NULL then the location of the physical address
- * bytes in the EDID will be returned here. This is set to 0
- * if there is no physical address found.
- *
- * Return: the physical address or CEC_PHYS_ADDR_INVALID if there is none.
- */
-u16 cec_get_edid_phys_addr(const u8 *edid, unsigned int size,
- unsigned int *offset);
-
-/**
- * cec_set_edid_phys_addr() - find and set the physical address
- *
- * @edid: pointer to the EDID data
- * @size: size in bytes of the EDID data
- * @phys_addr: the new physical address
- *
- * This function finds the location of the physical address in the EDID
- * and fills in the given physical address and updates the checksum
- * at the end of the EDID block. It does nothing if the EDID doesn't
- * contain a physical address.
- */
-void cec_set_edid_phys_addr(u8 *edid, unsigned int size, u16 phys_addr);
-
-/**
- * cec_phys_addr_for_input() - calculate the PA for an input
- *
- * @phys_addr: the physical address of the parent
- * @input: the number of the input port, must be between 1 and 15
- *
- * This function calculates a new physical address based on the input
- * port number. For example:
- *
- * PA = 0.0.0.0 and input = 2 becomes 2.0.0.0
- *
- * PA = 3.0.0.0 and input = 1 becomes 3.1.0.0
- *
- * PA = 3.2.1.0 and input = 5 becomes 3.2.1.5
- *
- * PA = 3.2.1.3 and input = 5 becomes f.f.f.f since it maxed out the depth.
- *
- * Return: the new physical address or CEC_PHYS_ADDR_INVALID.
- */
-u16 cec_phys_addr_for_input(u16 phys_addr, u8 input);
-
-/**
- * cec_phys_addr_validate() - validate a physical address from an EDID
- *
- * @phys_addr: the physical address to validate
- * @parent: if not %NULL, then this is filled with the parents PA.
- * @port: if not %NULL, then this is filled with the input port.
- *
- * This validates a physical address as read from an EDID. If the
- * PA is invalid (such as 1.0.1.0 since '0' is only allowed at the end),
- * then it will return -EINVAL.
- *
- * The parent PA is passed into %parent and the input port is passed into
- * %port. For example:
- *
- * PA = 0.0.0.0: has parent 0.0.0.0 and input port 0.
- *
- * PA = 1.0.0.0: has parent 0.0.0.0 and input port 1.
- *
- * PA = 3.2.0.0: has parent 3.0.0.0 and input port 2.
- *
- * PA = f.f.f.f: has parent f.f.f.f and input port 0.
- *
- * Return: 0 if the PA is valid, -EINVAL if not.
- */
-int cec_phys_addr_validate(u16 phys_addr, u16 *parent, u16 *port);
-
-#else
-
-static inline u16 cec_get_edid_phys_addr(const u8 *edid, unsigned int size,
- unsigned int *offset)
-{
- if (offset)
- *offset = 0;
- return CEC_PHYS_ADDR_INVALID;
-}
-
-static inline void cec_set_edid_phys_addr(u8 *edid, unsigned int size,
- u16 phys_addr)
-{
-}
-
-static inline u16 cec_phys_addr_for_input(u16 phys_addr, u8 input)
-{
- return CEC_PHYS_ADDR_INVALID;
-}
-
-static inline int cec_phys_addr_validate(u16 phys_addr, u16 *parent, u16 *port)
-{
- return 0;
-}
-
-#endif
-
-#endif /* _MEDIA_CEC_EDID_H */
diff --git a/include/media/cec-notifier.h b/include/media/cec-notifier.h
index 035712e0993d..eb50ce54b759 100644
--- a/include/media/cec-notifier.h
+++ b/include/media/cec-notifier.h
@@ -22,7 +22,7 @@
#define LINUX_CEC_NOTIFIER_H
#include <linux/types.h>
-#include <media/cec-edid.h>
+#include <media/cec.h>
struct device;
struct edid;
diff --git a/include/media/cec.h b/include/media/cec.h
index bae8d0153de7..b8eb895731d5 100644
--- a/include/media/cec.h
+++ b/include/media/cec.h
@@ -29,7 +29,6 @@
#include <linux/timer.h>
#include <linux/cec-funcs.h>
#include <media/rc-core.h>
-#include <media/cec-edid.h>
#include <media/cec-notifier.h>
/**
@@ -204,6 +203,9 @@ static inline bool cec_is_sink(const struct cec_adapter *adap)
return adap->phys_addr == 0;
}
+#define cec_phys_addr_exp(pa) \
+ ((pa) >> 12), ((pa) >> 8) & 0xf, ((pa) >> 4) & 0xf, (pa) & 0xf
+
#if IS_ENABLED(CONFIG_CEC_CORE)
struct cec_adapter *cec_allocate_adapter(const struct cec_adap_ops *ops,
void *priv, const char *name, u32 caps, u8 available_las);
@@ -223,6 +225,81 @@ void cec_transmit_done(struct cec_adapter *adap, u8 status, u8 arb_lost_cnt,
u8 nack_cnt, u8 low_drive_cnt, u8 error_cnt);
void cec_received_msg(struct cec_adapter *adap, struct cec_msg *msg);
+/**
+ * cec_get_edid_phys_addr() - find and return the physical address
+ *
+ * @edid: pointer to the EDID data
+ * @size: size in bytes of the EDID data
+ * @offset: If not %NULL then the location of the physical address
+ * bytes in the EDID will be returned here. This is set to 0
+ * if there is no physical address found.
+ *
+ * Return: the physical address or CEC_PHYS_ADDR_INVALID if there is none.
+ */
+u16 cec_get_edid_phys_addr(const u8 *edid, unsigned int size,
+ unsigned int *offset);
+
+/**
+ * cec_set_edid_phys_addr() - find and set the physical address
+ *
+ * @edid: pointer to the EDID data
+ * @size: size in bytes of the EDID data
+ * @phys_addr: the new physical address
+ *
+ * This function finds the location of the physical address in the EDID
+ * and fills in the given physical address and updates the checksum
+ * at the end of the EDID block. It does nothing if the EDID doesn't
+ * contain a physical address.
+ */
+void cec_set_edid_phys_addr(u8 *edid, unsigned int size, u16 phys_addr);
+
+/**
+ * cec_phys_addr_for_input() - calculate the PA for an input
+ *
+ * @phys_addr: the physical address of the parent
+ * @input: the number of the input port, must be between 1 and 15
+ *
+ * This function calculates a new physical address based on the input
+ * port number. For example:
+ *
+ * PA = 0.0.0.0 and input = 2 becomes 2.0.0.0
+ *
+ * PA = 3.0.0.0 and input = 1 becomes 3.1.0.0
+ *
+ * PA = 3.2.1.0 and input = 5 becomes 3.2.1.5
+ *
+ * PA = 3.2.1.3 and input = 5 becomes f.f.f.f since it maxed out the depth.
+ *
+ * Return: the new physical address or CEC_PHYS_ADDR_INVALID.
+ */
+u16 cec_phys_addr_for_input(u16 phys_addr, u8 input);
+
+/**
+ * cec_phys_addr_validate() - validate a physical address from an EDID
+ *
+ * @phys_addr: the physical address to validate
+ * @parent: if not %NULL, then this is filled with the parents PA.
+ * @port: if not %NULL, then this is filled with the input port.
+ *
+ * This validates a physical address as read from an EDID. If the
+ * PA is invalid (such as 1.0.1.0 since '0' is only allowed at the end),
+ * then it will return -EINVAL.
+ *
+ * The parent PA is passed into %parent and the input port is passed into
+ * %port. For example:
+ *
+ * PA = 0.0.0.0: has parent 0.0.0.0 and input port 0.
+ *
+ * PA = 1.0.0.0: has parent 0.0.0.0 and input port 1.
+ *
+ * PA = 3.2.0.0: has parent 3.0.0.0 and input port 2.
+ *
+ * PA = f.f.f.f: has parent f.f.f.f and input port 0.
+ *
+ * Return: 0 if the PA is valid, -EINVAL if not.
+ */
+int cec_phys_addr_validate(u16 phys_addr, u16 *parent, u16 *port);
+
#ifdef CONFIG_MEDIA_CEC_NOTIFIER
void cec_register_cec_notifier(struct cec_adapter *adap,
struct cec_notifier *notifier);
@@ -249,6 +326,29 @@ static inline void cec_s_phys_addr(struct cec_adapter *adap, u16 phys_addr,
{
}
+static inline u16 cec_get_edid_phys_addr(const u8 *edid, unsigned int size,
+ unsigned int *offset)
+{
+ if (offset)
+ *offset = 0;
+ return CEC_PHYS_ADDR_INVALID;
+}
+
+static inline void cec_set_edid_phys_addr(u8 *edid, unsigned int size,
+ u16 phys_addr)
+{
+}
+
+static inline u16 cec_phys_addr_for_input(u16 phys_addr, u8 input)
+{
+ return CEC_PHYS_ADDR_INVALID;
+}
+
+static inline int cec_phys_addr_validate(u16 phys_addr, u16 *parent, u16 *port)
+{
+ return 0;
+}
+
#endif
#endif /* _MEDIA_CEC_H */