diff options
author | Chuck Lever <chuck.lever@oracle.com> | 2017-02-08 17:00:10 -0500 |
---|---|---|
committer | Anna Schumaker <Anna.Schumaker@Netapp.com> | 2017-02-10 14:02:36 -0500 |
commit | 16f906d66cd76fb9895cbc628f447532a7ac1faa (patch) | |
tree | c43d002d1c1922281c3adf440282b4944814d0ac /net/sunrpc/xprtrdma/rpc_rdma.c | |
parent | c95a3c6b88658bcb8f77f85f31a0b9d9036e8016 (diff) |
xprtrdma: Reduce required number of send SGEs
The MAX_SEND_SGES check introduced in commit 655fec6987be
("xprtrdma: Use gathered Send for large inline messages") fails
for devices that have a small max_sge.
Instead of checking for a large fixed maximum number of SGEs,
check for a minimum small number. RPC-over-RDMA will switch to
using a Read chunk if an xdr_buf has more pages than can fit in
the device's max_sge limit. This is considerably better than
failing all together to mount the server.
This fix supports devices that have as few as three send SGEs
available.
Reported-by: Selvin Xavier <selvin.xavier@broadcom.com>
Reported-by: Devesh Sharma <devesh.sharma@broadcom.com>
Reported-by: Honggang Li <honli@redhat.com>
Reported-by: Ram Amrani <Ram.Amrani@cavium.com>
Fixes: 655fec6987be ("xprtrdma: Use gathered Send for large ...")
Cc: stable@vger.kernel.org # v4.9+
Tested-by: Honggang Li <honli@redhat.com>
Tested-by: Ram Amrani <Ram.Amrani@cavium.com>
Tested-by: Steve Wise <swise@opengridcomputing.com>
Reviewed-by: Parav Pandit <parav@mellanox.com>
Signed-off-by: Chuck Lever <chuck.lever@oracle.com>
Signed-off-by: Anna Schumaker <Anna.Schumaker@Netapp.com>
Diffstat (limited to 'net/sunrpc/xprtrdma/rpc_rdma.c')
-rw-r--r-- | net/sunrpc/xprtrdma/rpc_rdma.c | 26 |
1 files changed, 23 insertions, 3 deletions
diff --git a/net/sunrpc/xprtrdma/rpc_rdma.c b/net/sunrpc/xprtrdma/rpc_rdma.c index c634f0f3f9ce..d88988365cd2 100644 --- a/net/sunrpc/xprtrdma/rpc_rdma.c +++ b/net/sunrpc/xprtrdma/rpc_rdma.c @@ -125,14 +125,34 @@ void rpcrdma_set_max_header_sizes(struct rpcrdma_xprt *r_xprt) /* The client can send a request inline as long as the RPCRDMA header * plus the RPC call fit under the transport's inline limit. If the * combined call message size exceeds that limit, the client must use - * the read chunk list for this operation. + * a Read chunk for this operation. + * + * A Read chunk is also required if sending the RPC call inline would + * exceed this device's max_sge limit. */ static bool rpcrdma_args_inline(struct rpcrdma_xprt *r_xprt, struct rpc_rqst *rqst) { - struct rpcrdma_ia *ia = &r_xprt->rx_ia; + struct xdr_buf *xdr = &rqst->rq_snd_buf; + unsigned int count, remaining, offset; + + if (xdr->len > r_xprt->rx_ia.ri_max_inline_write) + return false; - return rqst->rq_snd_buf.len <= ia->ri_max_inline_write; + if (xdr->page_len) { + remaining = xdr->page_len; + offset = xdr->page_base & ~PAGE_MASK; + count = 0; + while (remaining) { + remaining -= min_t(unsigned int, + PAGE_SIZE - offset, remaining); + offset = 0; + if (++count > r_xprt->rx_ia.ri_max_send_sges) + return false; + } + } + + return true; } /* The client can't know how large the actual reply will be. Thus it |