authorEd Swierk <eswierk@skyportsystems.com>2017-07-19 17:44:40 -0700
committerZhang Rui <rui.zhang@intel.com>2017-08-15 14:32:58 +0800
commit595536e0b2475a9eac23709cd461143178c12e0e (patch)
treee7a5b374e55453cfe0cf98b4264052c1f482d609 /net/ceph/msgpool.c
parent38e44da591303d08b0d965a033e11ade284999d0 (diff)
thermal: intel_pch_thermal: Fix enable check on Broadwell-DE
Using the TSDSS flag to determine whether the thermal sensor is enabled is problematic. Broadwell-DE (Xeon D-1500) does not support dynamic shutdown and the TSDSS flag always reads 0 (contrary to the current datasheet). Even on hardware supporting dynamic shutdown, the driver does nothing to configure it, and the dynamic shutdown state should not prevent the driver from loading. The ETS flag itself indicates whether the thermal sensor is enabled, so use it instead of the TSDSS flag on all hardware platforms. Signed-off-by: Ed Swierk <eswierk@skyportsystems.com> Reviewed-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com> Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Diffstat (limited to 'net/ceph/msgpool.c')