summaryrefslogtreecommitdiff
path: root/drivers/thermal/intel/int340x_thermal
diff options
context:
space:
mode:
authorLinus Torvalds <torvalds@linux-foundation.org>2019-07-18 09:32:28 -0700
committerLinus Torvalds <torvalds@linux-foundation.org>2019-07-18 09:32:28 -0700
commitd0411ec8ca6b98061023873e334323ef102100cc (patch)
treeef7aa05ba464fc5d59c8753e5fb8599bf628937b /drivers/thermal/intel/int340x_thermal
parent4b09ddbcd107e280077bd3e918c8089dfa426980 (diff)
parent918e162e6a71e924a343b41f71789ad14e1e3229 (diff)
Merge tag 'pm-5.3-rc1-2' of git://git.kernel.org/pub/scm/linux/kernel/git/rafael/linux-pm
Pull more power management updates from Rafael Wysocki: "These modify the Intel RAPL driver to allow it to use an MMIO interface to the hardware, make the int340X thermal driver provide such an interface for it, add Intel Ice Lake CPU IDs to the RAPL driver (these changes depend on the previously merged x86 arch changes), update cpufreq to use the PM QoS framework for managing the min and max frequency limits, and add update the imx-cpufreq-dt cpufreq driver to support i.MX8MN. Specifics: - Add MMIO interface support to the Intel RAPL power capping driver and update the int340X thermal driver to provide a RAPL MMIO interface (Zhang Rui, Stephen Rothwell). - Add Intel Ice Lake CPU IDs to the RAPL driver (Zhang Rui, Rajneesh Bhardwaj). - Make cpufreq use the PM QoS framework (instead of notifiers) for managing the min and max frequency constraints (Viresh Kumar). - Add i.MX8MN support to the imx-cpufreq-dt cpufreq driver (Anson Huang)" * tag 'pm-5.3-rc1-2' of git://git.kernel.org/pub/scm/linux/kernel/git/rafael/linux-pm: (27 commits) cpufreq: Make cpufreq_generic_init() return void intel_rapl: need linux/cpuhotplug.h for enum cpuhp_state powercap/rapl: Add Ice Lake NNPI support to RAPL driver powercap/intel_rapl: add support for ICX-D powercap/intel_rapl: add support for ICX powercap/intel_rapl: add support for IceLake desktop intel_rapl: Fix module autoloading issue int340X/processor_thermal_device: add support for MMIO RAPL intel_rapl: support two power limits for every RAPL domain intel_rapl: support 64 bit register intel_rapl: abstract RAPL common code intel_rapl: cleanup hardcoded MSR access intel_rapl: cleanup some functions intel_rapl: abstract register access operations intel_rapl: abstract register address intel_rapl: introduce struct rapl_if_private intel_rapl: introduce intel_rapl.h intel_rapl: remove hardcoded register index intel_rapl: use reg instead of msr cpufreq: imx-cpufreq-dt: Add i.MX8MN support ...
Diffstat (limited to 'drivers/thermal/intel/int340x_thermal')
-rw-r--r--drivers/thermal/intel/int340x_thermal/Kconfig6
-rw-r--r--drivers/thermal/intel/int340x_thermal/processor_thermal_device.c173
2 files changed, 173 insertions, 6 deletions
diff --git a/drivers/thermal/intel/int340x_thermal/Kconfig b/drivers/thermal/intel/int340x_thermal/Kconfig
index 5333e018c88c..797907542e43 100644
--- a/drivers/thermal/intel/int340x_thermal/Kconfig
+++ b/drivers/thermal/intel/int340x_thermal/Kconfig
@@ -40,4 +40,10 @@ config INT3406_THERMAL
brightness in order to address a thermal condition or to reduce
power consumed by display device.
+config PROC_THERMAL_MMIO_RAPL
+ bool
+ depends on 64BIT
+ depends on POWERCAP
+ select INTEL_RAPL_CORE
+ default y
endif
diff --git a/drivers/thermal/intel/int340x_thermal/processor_thermal_device.c b/drivers/thermal/intel/int340x_thermal/processor_thermal_device.c
index 77dae1e7c3bf..213ab3cc6b80 100644
--- a/drivers/thermal/intel/int340x_thermal/processor_thermal_device.c
+++ b/drivers/thermal/intel/int340x_thermal/processor_thermal_device.c
@@ -11,6 +11,8 @@
#include <linux/platform_device.h>
#include <linux/acpi.h>
#include <linux/thermal.h>
+#include <linux/cpuhotplug.h>
+#include <linux/intel_rapl.h>
#include "int340x_thermal_zone.h"
#include "../intel_soc_dts_iosf.h"
@@ -37,6 +39,8 @@
/* GeminiLake thermal reporting device */
#define PCI_DEVICE_ID_PROC_GLK_THERMAL 0x318C
+#define DRV_NAME "proc_thermal"
+
struct power_config {
u32 index;
u32 min_uw;
@@ -52,6 +56,7 @@ struct proc_thermal_device {
struct power_config power_limits[2];
struct int34x_thermal_zone *int340x_zone;
struct intel_soc_dts_sensors *soc_dts;
+ void __iomem *mmio_base;
};
enum proc_thermal_emum_mode_type {
@@ -60,6 +65,12 @@ enum proc_thermal_emum_mode_type {
PROC_THERMAL_PLATFORM_DEV
};
+struct rapl_mmio_regs {
+ u64 reg_unit;
+ u64 regs[RAPL_DOMAIN_MAX][RAPL_DOMAIN_REG_MAX];
+ int limits[RAPL_DOMAIN_MAX];
+};
+
/*
* We can have only one type of enumeration, PCI or Platform,
* not both. So we don't need instance specific data.
@@ -367,8 +378,151 @@ static irqreturn_t proc_thermal_pci_msi_irq(int irq, void *devid)
return IRQ_HANDLED;
}
+#ifdef CONFIG_PROC_THERMAL_MMIO_RAPL
+
+#define MCHBAR 0
+
+/* RAPL Support via MMIO interface */
+static struct rapl_if_priv rapl_mmio_priv;
+
+static int rapl_mmio_cpu_online(unsigned int cpu)
+{
+ struct rapl_package *rp;
+
+ /* mmio rapl supports package 0 only for now */
+ if (topology_physical_package_id(cpu))
+ return 0;
+
+ rp = rapl_find_package_domain(cpu, &rapl_mmio_priv);
+ if (!rp) {
+ rp = rapl_add_package(cpu, &rapl_mmio_priv);
+ if (IS_ERR(rp))
+ return PTR_ERR(rp);
+ }
+ cpumask_set_cpu(cpu, &rp->cpumask);
+ return 0;
+}
+
+static int rapl_mmio_cpu_down_prep(unsigned int cpu)
+{
+ struct rapl_package *rp;
+ int lead_cpu;
+
+ rp = rapl_find_package_domain(cpu, &rapl_mmio_priv);
+ if (!rp)
+ return 0;
+
+ cpumask_clear_cpu(cpu, &rp->cpumask);
+ lead_cpu = cpumask_first(&rp->cpumask);
+ if (lead_cpu >= nr_cpu_ids)
+ rapl_remove_package(rp);
+ else if (rp->lead_cpu == cpu)
+ rp->lead_cpu = lead_cpu;
+ return 0;
+}
+
+static int rapl_mmio_read_raw(int cpu, struct reg_action *ra)
+{
+ if (!ra->reg)
+ return -EINVAL;
+
+ ra->value = readq((void __iomem *)ra->reg);
+ ra->value &= ra->mask;
+ return 0;
+}
+
+static int rapl_mmio_write_raw(int cpu, struct reg_action *ra)
+{
+ u64 val;
+
+ if (!ra->reg)
+ return -EINVAL;
+
+ val = readq((void __iomem *)ra->reg);
+ val &= ~ra->mask;
+ val |= ra->value;
+ writeq(val, (void __iomem *)ra->reg);
+ return 0;
+}
+
+static int proc_thermal_rapl_add(struct pci_dev *pdev,
+ struct proc_thermal_device *proc_priv,
+ struct rapl_mmio_regs *rapl_regs)
+{
+ enum rapl_domain_reg_id reg;
+ enum rapl_domain_type domain;
+ int ret;
+
+ if (!rapl_regs)
+ return 0;
+
+ ret = pcim_iomap_regions(pdev, 1 << MCHBAR, DRV_NAME);
+ if (ret) {
+ dev_err(&pdev->dev, "cannot reserve PCI memory region\n");
+ return -ENOMEM;
+ }
+
+ proc_priv->mmio_base = pcim_iomap_table(pdev)[MCHBAR];
+
+ for (domain = RAPL_DOMAIN_PACKAGE; domain < RAPL_DOMAIN_MAX; domain++) {
+ for (reg = RAPL_DOMAIN_REG_LIMIT; reg < RAPL_DOMAIN_REG_MAX; reg++)
+ if (rapl_regs->regs[domain][reg])
+ rapl_mmio_priv.regs[domain][reg] =
+ (u64)proc_priv->mmio_base +
+ rapl_regs->regs[domain][reg];
+ rapl_mmio_priv.limits[domain] = rapl_regs->limits[domain];
+ }
+ rapl_mmio_priv.reg_unit = (u64)proc_priv->mmio_base + rapl_regs->reg_unit;
+
+ rapl_mmio_priv.read_raw = rapl_mmio_read_raw;
+ rapl_mmio_priv.write_raw = rapl_mmio_write_raw;
+
+ rapl_mmio_priv.control_type = powercap_register_control_type(NULL, "intel-rapl-mmio", NULL);
+ if (IS_ERR(rapl_mmio_priv.control_type)) {
+ pr_debug("failed to register powercap control_type.\n");
+ return PTR_ERR(rapl_mmio_priv.control_type);
+ }
+
+ ret = cpuhp_setup_state(CPUHP_AP_ONLINE_DYN, "powercap/rapl:online",
+ rapl_mmio_cpu_online, rapl_mmio_cpu_down_prep);
+ if (ret < 0) {
+ powercap_unregister_control_type(rapl_mmio_priv.control_type);
+ return ret;
+ }
+ rapl_mmio_priv.pcap_rapl_online = ret;
+
+ return 0;
+}
+
+static void proc_thermal_rapl_remove(void)
+{
+ cpuhp_remove_state(rapl_mmio_priv.pcap_rapl_online);
+ powercap_unregister_control_type(rapl_mmio_priv.control_type);
+}
+
+static const struct rapl_mmio_regs rapl_mmio_hsw = {
+ .reg_unit = 0x5938,
+ .regs[RAPL_DOMAIN_PACKAGE] = { 0x59a0, 0x593c, 0x58f0, 0, 0x5930},
+ .regs[RAPL_DOMAIN_DRAM] = { 0x58e0, 0x58e8, 0x58ec, 0, 0},
+ .limits[RAPL_DOMAIN_PACKAGE] = 2,
+ .limits[RAPL_DOMAIN_DRAM] = 2,
+};
+
+#else
+
+static int proc_thermal_rapl_add(struct pci_dev *pdev,
+ struct proc_thermal_device *proc_priv,
+ struct rapl_mmio_regs *rapl_regs)
+{
+ return 0;
+}
+static void proc_thermal_rapl_remove(void) {}
+static const struct rapl_mmio_regs rapl_mmio_hsw;
+
+#endif /* CONFIG_MMIO_RAPL */
+
static int proc_thermal_pci_probe(struct pci_dev *pdev,
- const struct pci_device_id *unused)
+ const struct pci_device_id *id)
{
struct proc_thermal_device *proc_priv;
int ret;
@@ -378,15 +532,21 @@ static int proc_thermal_pci_probe(struct pci_dev *pdev,
return -ENODEV;
}
- ret = pci_enable_device(pdev);
+ ret = pcim_enable_device(pdev);
if (ret < 0) {
dev_err(&pdev->dev, "error: could not enable device\n");
return ret;
}
ret = proc_thermal_add(&pdev->dev, &proc_priv);
+ if (ret)
+ return ret;
+
+ ret = proc_thermal_rapl_add(pdev, proc_priv,
+ (struct rapl_mmio_regs *)id->driver_data);
if (ret) {
- pci_disable_device(pdev);
+ dev_err(&pdev->dev, "failed to add RAPL MMIO interface\n");
+ proc_thermal_remove(proc_priv);
return ret;
}
@@ -439,8 +599,8 @@ static void proc_thermal_pci_remove(struct pci_dev *pdev)
pci_disable_msi(pdev);
}
}
+ proc_thermal_rapl_remove();
proc_thermal_remove(proc_priv);
- pci_disable_device(pdev);
}
#ifdef CONFIG_PM_SLEEP
@@ -462,7 +622,8 @@ static SIMPLE_DEV_PM_OPS(proc_thermal_pm, NULL, proc_thermal_resume);
static const struct pci_device_id proc_thermal_pci_ids[] = {
{ PCI_DEVICE(PCI_VENDOR_ID_INTEL, PCI_DEVICE_ID_PROC_BDW_THERMAL)},
{ PCI_DEVICE(PCI_VENDOR_ID_INTEL, PCI_DEVICE_ID_PROC_HSB_THERMAL)},
- { PCI_DEVICE(PCI_VENDOR_ID_INTEL, PCI_DEVICE_ID_PROC_SKL_THERMAL)},
+ { PCI_DEVICE(PCI_VENDOR_ID_INTEL, PCI_DEVICE_ID_PROC_SKL_THERMAL),
+ .driver_data = (kernel_ulong_t)&rapl_mmio_hsw, },
{ PCI_DEVICE(PCI_VENDOR_ID_INTEL, PCI_DEVICE_ID_PROC_BSW_THERMAL)},
{ PCI_DEVICE(PCI_VENDOR_ID_INTEL, PCI_DEVICE_ID_PROC_BXT0_THERMAL)},
{ PCI_DEVICE(PCI_VENDOR_ID_INTEL, PCI_DEVICE_ID_PROC_BXT1_THERMAL)},
@@ -477,7 +638,7 @@ static const struct pci_device_id proc_thermal_pci_ids[] = {
MODULE_DEVICE_TABLE(pci, proc_thermal_pci_ids);
static struct pci_driver proc_thermal_pci_driver = {
- .name = "proc_thermal",
+ .name = DRV_NAME,
.probe = proc_thermal_pci_probe,
.remove = proc_thermal_pci_remove,
.id_table = proc_thermal_pci_ids,