diff options
author | Johan Meiring <johanmeiring@gmail.com> | 2012-11-20 16:44:58 +0200 |
---|---|---|
committer | Greg Kroah-Hartman <gregkh@linuxfoundation.org> | 2012-11-21 13:53:27 -0800 |
commit | 0da7da721a80d169e02c5eb730247df6aec56e9b (patch) | |
tree | c9edaa70b59b80f61f5dafe1c934dfd6f6f610d4 /drivers/staging/wlags49_h2 | |
parent | 5aeb6fcbab02f54e6976acd020999c20e22735bc (diff) |
staging: wlags49_h2: wl_if.h: gets rid of C99 // comments
This commit converts all C99 // comments to standard /* */ comments
Signed-off-by: Johan Meiring <johanmeiring@gmail.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Diffstat (limited to 'drivers/staging/wlags49_h2')
-rw-r--r-- | drivers/staging/wlags49_h2/wl_if.h | 39 |
1 files changed, 16 insertions, 23 deletions
diff --git a/drivers/staging/wlags49_h2/wl_if.h b/drivers/staging/wlags49_h2/wl_if.h index 351d29b821ea..425d3733b362 100644 --- a/drivers/staging/wlags49_h2/wl_if.h +++ b/drivers/staging/wlags49_h2/wl_if.h @@ -80,24 +80,17 @@ #define TX_TIMEOUT ((800 * HZ) / 1000) -//#define HCF_MIN_COMM_QUALITY 0 -//#define HCF_MAX_COMM_QUALITY 92 -//#define HCF_MIN_SIGNAL_LEVEL 47 -//#define HCF_MAX_SIGNAL_LEVEL 138 -//#define HCF_MIN_NOISE_LEVEL 47 -//#define HCF_MAX_NOISE_LEVEL 138 -//#define HCF_0DBM_OFFSET 149 - -// PE1DNN -// Better data from the real world. Not scientific but empirical data gathered -// from a Thomson Speedtouch 110 which is identified as: -// PCMCIA Info: "Agere Systems" "Wireless PC Card Model 0110" -// Manufacture ID: 0156,0003 -// Lowest measurment for noise floor seen is value 54 -// Highest signal strength in close proximity to the AP seen is value 118 -// Very good must be around 100 (otherwise its never "full scale" -// All other constants are derrived from these. This makes the signal gauge -// work for me... +/* PE1DNN + * Better data from the real world. Not scientific but empirical data gathered + * from a Thomson Speedtouch 110 which is identified as: + * PCMCIA Info: "Agere Systems" "Wireless PC Card Model 0110" + * Manufacture ID: 0156,0003 + * Lowest measurment for noise floor seen is value 54 + * Highest signal strength in close proximity to the AP seen is value 118 + * Very good must be around 100 (otherwise its never "full scale" + * All other constants are derrived from these. This makes the signal gauge + * work for me... + */ #define HCF_MIN_SIGNAL_LEVEL 54 #define HCF_MAX_SIGNAL_LEVEL 100 #define HCF_MIN_NOISE_LEVEL HCF_MIN_SIGNAL_LEVEL @@ -109,8 +102,8 @@ /* For encryption (WEP) */ -#define MIN_KEY_SIZE 5 // 40 bits RC4 - WEP -#define MAX_KEY_SIZE 13 // 104 bits +#define MIN_KEY_SIZE 5 /* 40 bits RC4 - WEP */ +#define MAX_KEY_SIZE 13 /* 104 bits */ #define MAX_KEYS 4 #define RADIO_CHANNELS 14 @@ -126,8 +119,8 @@ #define HCF_FAILURE 0xFF #define UIL_FAILURE 0xFF -#define CFG_UIL_CONNECT 0xA123 // Define differently? -#define CFG_UIL_CONNECT_ACK_CODE 0x5653435A // VSCZ +#define CFG_UIL_CONNECT 0xA123 /* Define differently? */ +#define CFG_UIL_CONNECT_ACK_CODE 0x5653435A /* VSCZ */ #define WVLAN2_UIL_CONNECTED (0x01L << 0) #define WVLAN2_UIL_BUSY (0x01L << 1) @@ -224,5 +217,5 @@ struct rtsreq { }; -#endif // __WAVELAN2_IF_H__ +#endif /* __WAVELAN2_IF_H__ */ |