diff options
author | James Smart <jsmart2021@gmail.com> | 2018-10-23 13:41:04 -0700 |
---|---|---|
committer | Martin K. Petersen <martin.petersen@oracle.com> | 2018-11-06 20:42:50 -0500 |
commit | 5cca2ab1b3a8316f94a987a5b23f1ea149bd3ef8 (patch) | |
tree | 20ed6bfbbfd44d5e9ccf2a1ffdaa4df468f7e147 /drivers/scsi | |
parent | 30e196cacefdd9a38c857caed23cefc9621bc5c1 (diff) |
scsi: lpfc: Reset link or adapter instead of doing infinite nameserver PLOGI retry
Currently, PLOGI failures are infinitely delayed/retried. There have
been some fabric situations where the PLOGI's were to the nameserver
and it stopped responding. The retries would never clear up. A better
resolution in this situation is to retry a couple of times, then drop
the link and reinit. This brings back connectivity to the nameserver.
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <jsmart2021@gmail.com>
Reviewed-by: Hannes Reinecke <hare@suse.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Diffstat (limited to 'drivers/scsi')
-rw-r--r-- | drivers/scsi/lpfc/lpfc_crtn.h | 1 | ||||
-rw-r--r-- | drivers/scsi/lpfc/lpfc_els.c | 83 |
2 files changed, 83 insertions, 1 deletions
diff --git a/drivers/scsi/lpfc/lpfc_crtn.h b/drivers/scsi/lpfc/lpfc_crtn.h index e01136507780..e9b297a39e54 100644 --- a/drivers/scsi/lpfc/lpfc_crtn.h +++ b/drivers/scsi/lpfc/lpfc_crtn.h @@ -380,6 +380,7 @@ void lpfc_nvmet_buf_free(struct lpfc_hba *phba, void *virtp, dma_addr_t dma); void lpfc_in_buf_free(struct lpfc_hba *, struct lpfc_dmabuf *); void lpfc_rq_buf_free(struct lpfc_hba *phba, struct lpfc_dmabuf *mp); +int lpfc_link_reset(struct lpfc_vport *vport); /* Function prototypes. */ const char* lpfc_info(struct Scsi_Host *); diff --git a/drivers/scsi/lpfc/lpfc_els.c b/drivers/scsi/lpfc/lpfc_els.c index 8160a5ebad08..e3e851931394 100644 --- a/drivers/scsi/lpfc/lpfc_els.c +++ b/drivers/scsi/lpfc/lpfc_els.c @@ -3242,6 +3242,62 @@ lpfc_els_retry_delay_handler(struct lpfc_nodelist *ndlp) } /** + * lpfc_link_reset - Issue link reset + * @vport: pointer to a virtual N_Port data structure. + * + * This routine performs link reset by sending INIT_LINK mailbox command. + * For SLI-3 adapter, link attention interrupt is enabled before issuing + * INIT_LINK mailbox command. + * + * Return code + * 0 - Link reset initiated successfully + * 1 - Failed to initiate link reset + **/ +int +lpfc_link_reset(struct lpfc_vport *vport) +{ + struct lpfc_hba *phba = vport->phba; + LPFC_MBOXQ_t *mbox; + uint32_t control; + int rc; + + lpfc_printf_vlog(vport, KERN_ERR, LOG_ELS, + "2851 Attempt link reset\n"); + mbox = mempool_alloc(phba->mbox_mem_pool, GFP_KERNEL); + if (!mbox) { + lpfc_printf_log(phba, KERN_ERR, LOG_MBOX, + "2852 Failed to allocate mbox memory"); + return 1; + } + + /* Enable Link attention interrupts */ + if (phba->sli_rev <= LPFC_SLI_REV3) { + spin_lock_irq(&phba->hbalock); + phba->sli.sli_flag |= LPFC_PROCESS_LA; + control = readl(phba->HCregaddr); + control |= HC_LAINT_ENA; + writel(control, phba->HCregaddr); + readl(phba->HCregaddr); /* flush */ + spin_unlock_irq(&phba->hbalock); + } + + lpfc_init_link(phba, mbox, phba->cfg_topology, + phba->cfg_link_speed); + mbox->mbox_cmpl = lpfc_sli_def_mbox_cmpl; + mbox->vport = vport; + rc = lpfc_sli_issue_mbox(phba, mbox, MBX_NOWAIT); + if ((rc != MBX_BUSY) && (rc != MBX_SUCCESS)) { + lpfc_printf_log(phba, KERN_ERR, LOG_MBOX, + "2853 Failed to issue INIT_LINK " + "mbox command, rc:x%x\n", rc); + mempool_free(mbox, phba->mbox_mem_pool); + return 1; + } + + return 0; +} + +/** * lpfc_els_retry - Make retry decision on an els command iocb * @phba: pointer to lpfc hba data structure. * @cmdiocb: pointer to lpfc command iocb data structure. @@ -3277,6 +3333,7 @@ lpfc_els_retry(struct lpfc_hba *phba, struct lpfc_iocbq *cmdiocb, int logerr = 0; uint32_t cmd = 0; uint32_t did; + int link_reset = 0, rc; /* Note: context2 may be 0 for internal driver abort @@ -3358,7 +3415,6 @@ lpfc_els_retry(struct lpfc_hba *phba, struct lpfc_iocbq *cmdiocb, retry = 1; break; - case IOERR_SEQUENCE_TIMEOUT: case IOERR_INVALID_RPI: if (cmd == ELS_CMD_PLOGI && did == NameServer_DID) { @@ -3369,6 +3425,18 @@ lpfc_els_retry(struct lpfc_hba *phba, struct lpfc_iocbq *cmdiocb, } retry = 1; break; + + case IOERR_SEQUENCE_TIMEOUT: + if (cmd == ELS_CMD_PLOGI && + did == NameServer_DID && + (cmdiocb->retry + 1) == maxretry) { + /* Reset the Link */ + link_reset = 1; + break; + } + retry = 1; + delay = 100; + break; } break; @@ -3525,6 +3593,19 @@ lpfc_els_retry(struct lpfc_hba *phba, struct lpfc_iocbq *cmdiocb, break; } + if (link_reset) { + rc = lpfc_link_reset(vport); + if (rc) { + /* Do not give up. Retry PLOGI one more time and attempt + * link reset if PLOGI fails again. + */ + retry = 1; + delay = 100; + goto out_retry; + } + return 1; + } + if (did == FDMI_DID) retry = 1; |