summaryrefslogtreecommitdiff
path: root/drivers/scsi
diff options
context:
space:
mode:
authorChristoph Hellwig <hch@lst.de>2006-02-17 12:13:48 +0100
committerJames Bottomley <jejb@mulgrave.il.steeleye.com>2006-02-27 21:36:46 -0600
commit147aab6aa22ce7775be944f8fb9932aa000dda61 (patch)
tree21e01c0387755e6607e050beac0504ff1f4866cf /drivers/scsi
parent938050916f57f08e20595b1fa1c1e57c2fbf7243 (diff)
[SCSI] megaraid_sas: fix physical disk handling
This patch hides the devices completely from the midlayer instead. It requires the patch to handle the slave_configure failure I posted earlier. Signed-off-by: Christoph Hellwig <hch@lst.de> Signed-off-by: James Bottomley <James.Bottomley@SteelEye.com>
Diffstat (limited to 'drivers/scsi')
-rw-r--r--drivers/scsi/megaraid/megaraid_sas.c29
1 files changed, 15 insertions, 14 deletions
diff --git a/drivers/scsi/megaraid/megaraid_sas.c b/drivers/scsi/megaraid/megaraid_sas.c
index 7de267e14458..4f39dd01936d 100644
--- a/drivers/scsi/megaraid/megaraid_sas.c
+++ b/drivers/scsi/megaraid/megaraid_sas.c
@@ -793,6 +793,20 @@ megasas_queue_command(struct scsi_cmnd *scmd, void (*done) (struct scsi_cmnd *))
return 0;
}
+static int megasas_slave_configure(struct scsi_device *sdev)
+{
+ /*
+ * Don't export physical disk devices to the disk driver.
+ *
+ * FIXME: Currently we don't export them to the midlayer at all.
+ * That will be fixed once LSI engineers have audited the
+ * firmware for possible issues.
+ */
+ if (sdev->channel < MEGASAS_MAX_PD_CHANNELS && sdev->type == TYPE_DISK)
+ return -ENXIO;
+ return 0;
+}
+
/**
* megasas_wait_for_outstanding - Wait for all outstanding cmds
* @instance: Adapter soft state
@@ -943,6 +957,7 @@ static struct scsi_host_template megasas_template = {
.module = THIS_MODULE,
.name = "LSI Logic SAS based MegaRAID driver",
.proc_name = "megaraid_sas",
+ .slave_configure = megasas_slave_configure,
.queuecommand = megasas_queue_command,
.eh_device_reset_handler = megasas_reset_device,
.eh_bus_reset_handler = megasas_reset_bus_host,
@@ -1071,20 +1086,6 @@ megasas_complete_cmd(struct megasas_instance *instance, struct megasas_cmd *cmd,
break;
}
- /*
- * Don't export physical disk devices to mid-layer.
- */
- if (!MEGASAS_IS_LOGICAL(cmd->scmd) &&
- (hdr->cmd_status == MFI_STAT_OK) &&
- (cmd->scmd->cmnd[0] == INQUIRY)) {
-
- if (((*(u8 *) cmd->scmd->request_buffer) & 0x1F) ==
- TYPE_DISK) {
- cmd->scmd->result = DID_BAD_TARGET << 16;
- exception = 1;
- }
- }
-
case MFI_CMD_LD_READ:
case MFI_CMD_LD_WRITE: