parent | 19dd159ce8086293b70bd8e1aeebe06aff8d7df8 (diff) |
regulator: max8973: add support for junction thermal warning
The driver MAX8973 supports the driver for Maxim PMIC MAX77621.
MAX77621 supports the junction temp warning at 120 degC and
140 degC which is configurable. It generates alert signal when
junction temperature crosses these threshold.
MAX77621 does not support the continuous temp monitoring of
junction temperature. It just report whether junction temperature
crossed the threshold or not.
Add support to
- Configure junction temp warning threshold via DT property
to generate alert when it crosses the threshold.
- Add support to interrupt the host from this device when alert
occurred.
- read the junction temp via thermal framework.
Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
Diffstat (limited to 'drivers/regulator/Kconfig')
-rw-r--r-- | drivers/regulator/Kconfig | 1 |
1 files changed, 1 insertions, 0 deletions
diff --git a/drivers/regulator/Kconfig b/drivers/regulator/Kconfig index c77dc08b1202..129359f775d0 100644 --- a/drivers/regulator/Kconfig +++ b/drivers/regulator/Kconfig @@ -409,6 +409,7 @@ config REGULATOR_MAX8952 config REGULATOR_MAX8973 tristate "Maxim MAX8973 voltage regulator " depends on I2C + depends on THERMAL && THERMAL_OF select REGMAP_I2C help The MAXIM MAX8973 high-efficiency. three phase, DC-DC step-down |