summaryrefslogtreecommitdiff
path: root/drivers/net/ethernet/mscc
diff options
context:
space:
mode:
authorVladimir Oltean <vladimir.oltean@nxp.com>2020-07-22 11:08:57 +0300
committerDavid S. Miller <davem@davemloft.net>2020-07-22 13:02:09 -0700
commit8bb849d67f44b1a1280cda900ea02fdbc36d4363 (patch)
treed0d42b578dcad4f9e69dbfde6cc6c28dfec66f0b /drivers/net/ethernet/mscc
parenta6c0d0934f0d8d4e32a3e3bca4b503a3e7237470 (diff)
net: mscc: ocelot: fix non-initialized CPU port on VSC7514
The VSC7514 is marketed as a 10-port switch, however it has 11 physical ports (0->10) in the block diagram: https://www.microsemi.com/product-directory/ethernet-switches/3992-vsc7514 (also in the device tree at arch/mips/boot/dts/mscc/ocelot.dtsi) Additionally, by architecture it has one more entry in the analyzer block, situated right after the physical ports, for the CPU port module. This is not a physical port, it only represents a channel for frame injection and extraction. That entry for the CPU port is at index 11 in the analyzer. When the register groups for QSYS_SWITCH_PORT_MODE, SYS_PORT_MODE and SYS_PAUSE_CFG are declared to be replicated 11 times, the 11th entry in the array of regfields is not initialized, so the CPU port module is not initialized either. The documentation of QSYS_SWITCH_PORT_MODE for VSC7514 also says that this register group is replicated 12 times, so this patch is simply reflecting that and not introducing any further inconsistency. Fixes: 886e1387c73d ("net: mscc: ocelot: convert QSYS_SWITCH_PORT_MODE and SYS_PORT_MODE to regfields") Fixes: 541132f0961a ("net: mscc: ocelot: convert SYS_PAUSE_CFG register access to regfield") Reported-by: Bryan Whitehead <bryan.whitehead@microchip.com> Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'drivers/net/ethernet/mscc')
-rw-r--r--drivers/net/ethernet/mscc/ocelot_vsc7514.c28
1 files changed, 14 insertions, 14 deletions
diff --git a/drivers/net/ethernet/mscc/ocelot_vsc7514.c b/drivers/net/ethernet/mscc/ocelot_vsc7514.c
index 0ead1ef11c6c..65408bc994c4 100644
--- a/drivers/net/ethernet/mscc/ocelot_vsc7514.c
+++ b/drivers/net/ethernet/mscc/ocelot_vsc7514.c
@@ -358,20 +358,20 @@ static const struct reg_field ocelot_regfields[REGFIELD_MAX] = {
[SYS_RESET_CFG_CORE_ENA] = REG_FIELD(SYS_RESET_CFG, 2, 2),
[SYS_RESET_CFG_MEM_ENA] = REG_FIELD(SYS_RESET_CFG, 1, 1),
[SYS_RESET_CFG_MEM_INIT] = REG_FIELD(SYS_RESET_CFG, 0, 0),
- /* Replicated per number of ports (11), register size 4 per port */
- [QSYS_SWITCH_PORT_MODE_PORT_ENA] = REG_FIELD_ID(QSYS_SWITCH_PORT_MODE, 14, 14, 11, 4),
- [QSYS_SWITCH_PORT_MODE_SCH_NEXT_CFG] = REG_FIELD_ID(QSYS_SWITCH_PORT_MODE, 11, 13, 11, 4),
- [QSYS_SWITCH_PORT_MODE_YEL_RSRVD] = REG_FIELD_ID(QSYS_SWITCH_PORT_MODE, 10, 10, 11, 4),
- [QSYS_SWITCH_PORT_MODE_INGRESS_DROP_MODE] = REG_FIELD_ID(QSYS_SWITCH_PORT_MODE, 9, 9, 11, 4),
- [QSYS_SWITCH_PORT_MODE_TX_PFC_ENA] = REG_FIELD_ID(QSYS_SWITCH_PORT_MODE, 1, 8, 11, 4),
- [QSYS_SWITCH_PORT_MODE_TX_PFC_MODE] = REG_FIELD_ID(QSYS_SWITCH_PORT_MODE, 0, 0, 11, 4),
- [SYS_PORT_MODE_DATA_WO_TS] = REG_FIELD_ID(SYS_PORT_MODE, 5, 6, 11, 4),
- [SYS_PORT_MODE_INCL_INJ_HDR] = REG_FIELD_ID(SYS_PORT_MODE, 3, 4, 11, 4),
- [SYS_PORT_MODE_INCL_XTR_HDR] = REG_FIELD_ID(SYS_PORT_MODE, 1, 2, 11, 4),
- [SYS_PORT_MODE_INCL_HDR_ERR] = REG_FIELD_ID(SYS_PORT_MODE, 0, 0, 11, 4),
- [SYS_PAUSE_CFG_PAUSE_START] = REG_FIELD_ID(SYS_PAUSE_CFG, 10, 18, 11, 4),
- [SYS_PAUSE_CFG_PAUSE_STOP] = REG_FIELD_ID(SYS_PAUSE_CFG, 1, 9, 11, 4),
- [SYS_PAUSE_CFG_PAUSE_ENA] = REG_FIELD_ID(SYS_PAUSE_CFG, 0, 1, 11, 4),
+ /* Replicated per number of ports (12), register size 4 per port */
+ [QSYS_SWITCH_PORT_MODE_PORT_ENA] = REG_FIELD_ID(QSYS_SWITCH_PORT_MODE, 14, 14, 12, 4),
+ [QSYS_SWITCH_PORT_MODE_SCH_NEXT_CFG] = REG_FIELD_ID(QSYS_SWITCH_PORT_MODE, 11, 13, 12, 4),
+ [QSYS_SWITCH_PORT_MODE_YEL_RSRVD] = REG_FIELD_ID(QSYS_SWITCH_PORT_MODE, 10, 10, 12, 4),
+ [QSYS_SWITCH_PORT_MODE_INGRESS_DROP_MODE] = REG_FIELD_ID(QSYS_SWITCH_PORT_MODE, 9, 9, 12, 4),
+ [QSYS_SWITCH_PORT_MODE_TX_PFC_ENA] = REG_FIELD_ID(QSYS_SWITCH_PORT_MODE, 1, 8, 12, 4),
+ [QSYS_SWITCH_PORT_MODE_TX_PFC_MODE] = REG_FIELD_ID(QSYS_SWITCH_PORT_MODE, 0, 0, 12, 4),
+ [SYS_PORT_MODE_DATA_WO_TS] = REG_FIELD_ID(SYS_PORT_MODE, 5, 6, 12, 4),
+ [SYS_PORT_MODE_INCL_INJ_HDR] = REG_FIELD_ID(SYS_PORT_MODE, 3, 4, 12, 4),
+ [SYS_PORT_MODE_INCL_XTR_HDR] = REG_FIELD_ID(SYS_PORT_MODE, 1, 2, 12, 4),
+ [SYS_PORT_MODE_INCL_HDR_ERR] = REG_FIELD_ID(SYS_PORT_MODE, 0, 0, 12, 4),
+ [SYS_PAUSE_CFG_PAUSE_START] = REG_FIELD_ID(SYS_PAUSE_CFG, 10, 18, 12, 4),
+ [SYS_PAUSE_CFG_PAUSE_STOP] = REG_FIELD_ID(SYS_PAUSE_CFG, 1, 9, 12, 4),
+ [SYS_PAUSE_CFG_PAUSE_ENA] = REG_FIELD_ID(SYS_PAUSE_CFG, 0, 1, 12, 4),
};
static const struct ocelot_stat_layout ocelot_stats_layout[] = {