diff options
author | NeilBrown <neilb@suse.de> | 2012-07-03 11:46:53 +1000 |
---|---|---|
committer | NeilBrown <neilb@suse.de> | 2012-07-03 11:46:53 +1000 |
commit | 5cfb22a1f83e4f04c0a4df89b60053a077222e2b (patch) | |
tree | 9312c806fb3fb245beb0dd6669569f88a79a8b7d /drivers/md | |
parent | fc448a18ae6219af9a73257b1fbcd009efab4a81 (diff) |
md/raid5: prefer replacing failed devices over want-replacement devices.
If a RAID5 has both a failed device and a device marked as
'WantReplacement', then we should preferentially replace the failed
device.
However the current code replaces whichever is found first.
So split into 2 loops, check fail failed/missing first, and only check
for WantReplacement if nothing is failed or missing.
Reported-by: majianpeng <majianpeng@gmail.com>
Signed-off-by: NeilBrown <neilb@suse.de>
Diffstat (limited to 'drivers/md')
-rw-r--r-- | drivers/md/raid5.c | 13 |
1 files changed, 8 insertions, 5 deletions
diff --git a/drivers/md/raid5.c b/drivers/md/raid5.c index d26767246d26..95fcbbf3d6c9 100644 --- a/drivers/md/raid5.c +++ b/drivers/md/raid5.c @@ -5465,10 +5465,9 @@ static int raid5_add_disk(struct mddev *mddev, struct md_rdev *rdev) if (rdev->saved_raid_disk >= 0 && rdev->saved_raid_disk >= first && conf->disks[rdev->saved_raid_disk].rdev == NULL) - disk = rdev->saved_raid_disk; - else - disk = first; - for ( ; disk <= last ; disk++) { + first = rdev->saved_raid_disk; + + for (disk = first; disk <= last; disk++) { p = conf->disks + disk; if (p->rdev == NULL) { clear_bit(In_sync, &rdev->flags); @@ -5477,8 +5476,11 @@ static int raid5_add_disk(struct mddev *mddev, struct md_rdev *rdev) if (rdev->saved_raid_disk != disk) conf->fullsync = 1; rcu_assign_pointer(p->rdev, rdev); - break; + goto out; } + } + for (disk = first; disk <= last; disk++) { + p = conf->disks + disk; if (test_bit(WantReplacement, &p->rdev->flags) && p->replacement == NULL) { clear_bit(In_sync, &rdev->flags); @@ -5490,6 +5492,7 @@ static int raid5_add_disk(struct mddev *mddev, struct md_rdev *rdev) break; } } +out: print_raid5_conf(conf); return err; } |