authorValentin Schneider <valentin.schneider@arm.com>2020-07-12 17:59:15 +0100
committerPeter Zijlstra <peterz@infradead.org>2020-07-22 10:22:05 +0200
commit25980c7a79af42f2daa73e2f475ebf4cbac8253e (patch)
treee22a255eca9698525da7ea6e9de531bfefcf1f6b /drivers/base/arch_topology.c
parent2705937a0395bd15d515a2a302d26ebc8318c035 (diff)
arch_topology, sched/core: Cleanup thermal pressure definition
The following commit: 14533a16c46d ("thermal/cpu-cooling, sched/core: Move the arch_set_thermal_pressure() API to generic scheduler code") moved the definition of arch_set_thermal_pressure() to sched/core.c, but kept its declaration in linux/arch_topology.h. When building e.g. an x86 kernel with CONFIG_SCHED_THERMAL_PRESSURE=y, cpufreq_cooling.c ends up getting the declaration of arch_set_thermal_pressure() from include/linux/arch_topology.h, which is somewhat awkward. On top of this, sched/core.c unconditionally defines o The thermal_pressure percpu variable o arch_set_thermal_pressure() while arch_scale_thermal_pressure() does nothing unless redefined by the architecture. arch_*() functions are meant to be defined by architectures, so revert the aforementioned commit and re-implement it in a way that keeps arch_set_thermal_pressure() architecture-definable, and doesn't define the thermal pressure percpu variable for kernels that don't need it (CONFIG_SCHED_THERMAL_PRESSURE=n). Signed-off-by: Valentin Schneider <valentin.schneider@arm.com> Signed-off-by: Peter Zijlstra (Intel) <peterz@infradead.org> Link: https://lkml.kernel.org/r/20200712165917.9168-2-valentin.schneider@arm.com
Diffstat (limited to 'drivers/base/arch_topology.c')
-rw-r--r--drivers/base/arch_topology.c11
1 files changed, 11 insertions, 0 deletions
diff --git a/drivers/base/arch_topology.c b/drivers/base/arch_topology.c
index 4d0a0038b476..75f72d684294 100644
--- a/drivers/base/arch_topology.c
+++ b/drivers/base/arch_topology.c
@@ -54,6 +54,17 @@ void topology_set_cpu_scale(unsigned int cpu, unsigned long capacity)
per_cpu(cpu_scale, cpu) = capacity;
}
+DEFINE_PER_CPU(unsigned long, thermal_pressure);
+
+void topology_set_thermal_pressure(const struct cpumask *cpus,
+ unsigned long th_pressure)
+{
+ int cpu;
+
+ for_each_cpu(cpu, cpus)
+ WRITE_ONCE(per_cpu(thermal_pressure, cpu), th_pressure);
+}
+
static ssize_t cpu_capacity_show(struct device *dev,
struct device_attribute *attr,
char *buf)