commit4ba5a0fc6441194cf238e1a049f548b5d45760c8 (patch)
treef240274209fa46f55b4fff64761e0383bfbea1b7 /arch
parent9372dddb189a7a7689b674ad2dd31117a407bfd5 (diff)
powerpc/pseries: Decrease message level on EEH initialization
As Anton suggested, the patch decreases the message level on EEH initialization to avoid unnecessary messages if required. Also, we have unified hint if any of needful RTAS calls is missed, and then we can check /proc/device-tree to figure out the missed RTAS calls. Suggested-by: Anton Blanchard <anton@samba.org> Signed-off-by: Gavin Shan <gwshan@linux.vnet.ibm.com> Signed-off-by: Michael Ellerman <mpe@ellerman.id.au>
Diffstat (limited to 'arch')
-rw-r--r--arch/powerpc/platforms/pseries/eeh_pseries.c35
1 files changed, 10 insertions, 25 deletions
diff --git a/arch/powerpc/platforms/pseries/eeh_pseries.c b/arch/powerpc/platforms/pseries/eeh_pseries.c
index 4fc5ff96f418..a6c7e19f5eb3 100644
--- a/arch/powerpc/platforms/pseries/eeh_pseries.c
+++ b/arch/powerpc/platforms/pseries/eeh_pseries.c
@@ -88,29 +88,14 @@ static int pseries_eeh_init(void)
* and its variant since the old firmware probably support address
* of domain/bus/slot/function for EEH RTAS operations.
*/
- if (ibm_set_eeh_option == RTAS_UNKNOWN_SERVICE) {
- pr_warn("%s: RTAS service <ibm,set-eeh-option> invalid\n",
- __func__);
- return -EINVAL;
- } else if (ibm_set_slot_reset == RTAS_UNKNOWN_SERVICE) {
- pr_warn("%s: RTAS service <ibm,set-slot-reset> invalid\n",
- __func__);
- return -EINVAL;
- } else if (ibm_read_slot_reset_state2 == RTAS_UNKNOWN_SERVICE &&
- ibm_read_slot_reset_state == RTAS_UNKNOWN_SERVICE) {
- pr_warn("%s: RTAS service <ibm,read-slot-reset-state2> and "
- "<ibm,read-slot-reset-state> invalid\n",
- __func__);
- return -EINVAL;
- } else if (ibm_slot_error_detail == RTAS_UNKNOWN_SERVICE) {
- pr_warn("%s: RTAS service <ibm,slot-error-detail> invalid\n",
- __func__);
- return -EINVAL;
- } else if (ibm_configure_pe == RTAS_UNKNOWN_SERVICE &&
- ibm_configure_bridge == RTAS_UNKNOWN_SERVICE) {
- pr_warn("%s: RTAS service <ibm,configure-pe> and "
- "<ibm,configure-bridge> invalid\n",
- __func__);
+ if (ibm_set_eeh_option == RTAS_UNKNOWN_SERVICE ||
+ ibm_set_slot_reset == RTAS_UNKNOWN_SERVICE ||
+ (ibm_read_slot_reset_state2 == RTAS_UNKNOWN_SERVICE &&
+ ibm_read_slot_reset_state == RTAS_UNKNOWN_SERVICE) ||
+ ibm_slot_error_detail == RTAS_UNKNOWN_SERVICE ||
+ (ibm_configure_pe == RTAS_UNKNOWN_SERVICE &&
+ ibm_configure_bridge == RTAS_UNKNOWN_SERVICE)) {
+ pr_info("EEH functionality not supported\n");
return -EINVAL;
}
@@ -118,11 +103,11 @@ static int pseries_eeh_init(void)
spin_lock_init(&slot_errbuf_lock);
eeh_error_buf_size = rtas_token("rtas-error-log-max");
if (eeh_error_buf_size == RTAS_UNKNOWN_SERVICE) {
- pr_warn("%s: unknown EEH error log size\n",
+ pr_info("%s: unknown EEH error log size\n",
__func__);
eeh_error_buf_size = 1024;
} else if (eeh_error_buf_size > RTAS_ERROR_LOG_MAX) {
- pr_warn("%s: EEH error log size %d exceeds the maximal %d\n",
+ pr_info("%s: EEH error log size %d exceeds the maximal %d\n",
__func__, eeh_error_buf_size, RTAS_ERROR_LOG_MAX);
eeh_error_buf_size = RTAS_ERROR_LOG_MAX;
}