diff options
author | Gavin Shan <shangw@linux.vnet.ibm.com> | 2014-01-15 13:16:13 +0800 |
---|---|---|
committer | Benjamin Herrenschmidt <benh@kernel.crashing.org> | 2014-01-15 17:18:59 +1100 |
commit | cb5b242c8c14a4b1dcd358400da28208fde78947 (patch) | |
tree | b003655a84193071b8089d19b5bc1e9663574d1b /arch/powerpc/platforms/powernv/eeh-ioda.c | |
parent | 7e4e7867b1e551b7b8f326da3604c47332972bc6 (diff) |
powerpc/eeh: Escalate error on non-existing PE
Sometimes, especially in sinario of loading another kernel with kdump,
we got EEH error on non-existing PE. That means the PEEV / PEST in
the corresponding PHB would be messy and we can't handle that case.
The patch escalates the error to fenced PHB so that the PHB could be
rested in order to revoer the errors on non-existing PEs.
Reported-by: Mahesh Salgaonkar <mahesh@linux.vnet.ibm.com>
Signed-off-by: Gavin Shan <shangw@linux.vnet.ibm.com>
Tested-by: Mahesh Salgaonkar <mahesh@linux.vnet.ibm.com>
Signed-off-by: Benjamin Herrenschmidt <benh@kernel.crashing.org>
Diffstat (limited to 'arch/powerpc/platforms/powernv/eeh-ioda.c')
-rw-r--r-- | arch/powerpc/platforms/powernv/eeh-ioda.c | 31 |
1 files changed, 21 insertions, 10 deletions
diff --git a/arch/powerpc/platforms/powernv/eeh-ioda.c b/arch/powerpc/platforms/powernv/eeh-ioda.c index 8dd16f4675a2..e1e71618b70c 100644 --- a/arch/powerpc/platforms/powernv/eeh-ioda.c +++ b/arch/powerpc/platforms/powernv/eeh-ioda.c @@ -713,11 +713,7 @@ static int ioda_eeh_get_pe(struct pci_controller *hose, dev.phb = hose; dev.pe_config_addr = pe_no; dev_pe = eeh_pe_get(&dev); - if (!dev_pe) { - pr_warning("%s: Can't find PE for PHB#%x - PE#%x\n", - __func__, hose->global_number, pe_no); - return -EEXIST; - } + if (!dev_pe) return -EEXIST; *pe = dev_pe; return 0; @@ -831,12 +827,27 @@ static int ioda_eeh_next_error(struct eeh_pe **pe) break; case OPAL_EEH_PE_ERROR: - if (ioda_eeh_get_pe(hose, frozen_pe_no, pe)) - break; + /* + * If we can't find the corresponding PE, the + * PEEV / PEST would be messy. So we force an + * fenced PHB so that it can be recovered. + */ + if (ioda_eeh_get_pe(hose, frozen_pe_no, pe)) { + if (!ioda_eeh_get_phb_pe(hose, pe)) { + pr_err("EEH: Escalated fenced PHB#%x " + "detected for PE#%llx\n", + hose->global_number, + frozen_pe_no); + ret = EEH_NEXT_ERR_FENCED_PHB; + } else { + ret = EEH_NEXT_ERR_NONE; + } + } else { + pr_err("EEH: Frozen PE#%x on PHB#%x detected\n", + (*pe)->addr, (*pe)->phb->global_number); + ret = EEH_NEXT_ERR_FROZEN_PE; + } - pr_err("EEH: Frozen PE#%x on PHB#%x detected\n", - (*pe)->addr, (*pe)->phb->global_number); - ret = EEH_NEXT_ERR_FROZEN_PE; break; default: pr_warn("%s: Unexpected error type %d\n", |