summaryrefslogtreecommitdiff
path: root/arch/arm64/boot/dts/qcom/pm8916.dtsi
diff options
context:
space:
mode:
authorStephen Boyd <sboyd@codeaurora.org>2015-11-25 14:27:37 -0800
committerAndy Gross <andy.gross@linaro.org>2016-02-24 00:14:06 -0600
commitbd6429e81010fdfa8be9df7f136251f905d055f8 (patch)
tree190b816cc7e196544503c5cb0921416232206662 /arch/arm64/boot/dts/qcom/pm8916.dtsi
parenta70d74492b5ac988ae7ae686305e00d2b79c0bb2 (diff)
ARM64: dts: qcom: Remove size elements from pmic reg properties
The #size-cells for the pmics are 0, but we specify a size in the reg property so that MPP and GPIO modules can figure out how many pins there are. Now that we've done that by counting irqs, we can remove the size elements in the reg properties and be DT compliant. Signed-off-by: Stephen Boyd <sboyd@codeaurora.org> Acked-by: Andy Gross <andy.gross@linaro.org> Signed-off-by: Andy Gross <andy.gross@linaro.org>
Diffstat (limited to 'arch/arm64/boot/dts/qcom/pm8916.dtsi')
-rw-r--r--arch/arm64/boot/dts/qcom/pm8916.dtsi10
1 files changed, 5 insertions, 5 deletions
diff --git a/arch/arm64/boot/dts/qcom/pm8916.dtsi b/arch/arm64/boot/dts/qcom/pm8916.dtsi
index 37432451ee4c..f71679b15d54 100644
--- a/arch/arm64/boot/dts/qcom/pm8916.dtsi
+++ b/arch/arm64/boot/dts/qcom/pm8916.dtsi
@@ -12,7 +12,7 @@
rtc@6000 {
compatible = "qcom,pm8941-rtc";
- reg = <0x6000 0x6100>;
+ reg = <0x6000>;
reg-names = "rtc", "alarm";
interrupts = <0x0 0x61 0x1 IRQ_TYPE_EDGE_RISING>;
};
@@ -27,7 +27,7 @@
pm8916_gpios: gpios@c000 {
compatible = "qcom,pm8916-gpio";
- reg = <0xc000 0x400>;
+ reg = <0xc000>;
gpio-controller;
#gpio-cells = <2>;
interrupts = <0 0xc0 0 IRQ_TYPE_NONE>,
@@ -38,7 +38,7 @@
pm8916_mpps: mpps@a000 {
compatible = "qcom,pm8916-mpp";
- reg = <0xa000 0x400>;
+ reg = <0xa000>;
gpio-controller;
#gpio-cells = <2>;
interrupts = <0 0xa0 0 IRQ_TYPE_NONE>,
@@ -49,7 +49,7 @@
pm8916_temp: temp-alarm@2400 {
compatible = "qcom,spmi-temp-alarm";
- reg = <0x2400 0x100>;
+ reg = <0x2400>;
interrupts = <0 0x24 0 IRQ_TYPE_EDGE_RISING>;
io-channels = <&pm8916_vadc VADC_DIE_TEMP>;
io-channel-names = "thermal";
@@ -58,7 +58,7 @@
pm8916_vadc: vadc@3100 {
compatible = "qcom,spmi-vadc";
- reg = <0x3100 0x100>;
+ reg = <0x3100>;
interrupts = <0x0 0x31 0x0 IRQ_TYPE_EDGE_RISING>;
#address-cells = <1>;
#size-cells = <0>;