diff options
author | Marc Hulsman <m.hulsman@tudelft.nl> | 2008-10-17 17:51:17 +0200 |
---|---|---|
committer | Jean Delvare <khali@mahadeva.delvare> | 2008-10-17 17:51:17 +0200 |
commit | a5a4598cd2e7cae456a7f2a100bf0e5c3c7811c7 (patch) | |
tree | d2a5da96eae842f33bea66101a92abf88612aa9f /Documentation | |
parent | b5938f8c4a530b2fad18f2293ffaf79ac9f5a148 (diff) |
hwmon: (w83791d) add support for thermal cruise mode
Add support to set target temperature and tolerance for thermal
cruise mode.
Signed-off-by: Marc Hulsman <m.hulsman@tudelft.nl>
Acked-by: Hans de Goede <j.w.r.degoede@hhs.nl>
Signed-off-by: Jean Delvare <khali@linux-fr.org>
Diffstat (limited to 'Documentation')
-rw-r--r-- | Documentation/hwmon/w83791d | 19 |
1 files changed, 14 insertions, 5 deletions
diff --git a/Documentation/hwmon/w83791d b/Documentation/hwmon/w83791d index b1e4798764e8..5663e491655c 100644 --- a/Documentation/hwmon/w83791d +++ b/Documentation/hwmon/w83791d @@ -77,6 +77,9 @@ readings can be divided by a programmable divider (1, 2, 4, 8, 16, Each fan controlled is controlled by PWM. The PWM duty cycle can be read and set for each fan separately. Valid values range from 0 (stop) to 255 (full). +PWM 1-3 support Thermal Cruise mode, in which the PWMs are automatically +regulated to keep respectively temp 1-3 at a certain target temperature. +See below for the description of the sysfs-interface. The w83791d has a global bit used to enable beeping from the speaker when an alarm is triggered as well as a bitmask to enable or disable the beep for @@ -116,9 +119,19 @@ chip-specific options are documented here. pwm[1-3]_enable - this file controls mode of fan/temperature control for fan 1-3. Fan/PWM 4-5 only support manual mode. * 1 Manual mode - * 2 Thermal Cruise mode (no further support) + * 2 Thermal Cruise mode * 3 Fan Speed Cruise mode (no further support) +temp[1-3]_target - defines the target temperature for Thermal Cruise mode. + Unit: millidegree Celsius + RW + +temp[1-3]_tolerance - temperature tolerance for Thermal Cruise mode. + Specifies an interval around the target temperature + in which the fan speed is not changed. + Unit: millidegree Celsius + RW + Alarms bitmap vs. beep_mask bitmask ------------------------------------ For legacy code using the alarms and beep_mask files: @@ -146,7 +159,3 @@ tart2 : alarms: 0x020000 beep_mask: 0x080000 <== mismatch tart3 : alarms: 0x040000 beep_mask: 0x100000 <== mismatch case_open : alarms: 0x001000 beep_mask: 0x001000 global_enable: alarms: -------- beep_mask: 0x800000 (modified via beep_enable) - -W83791D TODO: ---------------- -Provide a patch for Thermal Cruise registers. |