diff options
author | Punit Agrawal <punit.agrawal@arm.com> | 2015-09-08 12:20:48 +0100 |
---|---|---|
committer | Rob Herring <robh@kernel.org> | 2015-09-17 14:36:36 -0500 |
commit | eb168b70dea54578a45119fcdb3b48ad5d75fed9 (patch) | |
tree | 42f3ff2d9e4e76d2ffb01420753c575c652270ce /Documentation/devicetree | |
parent | dc4dae00d82fedcd7a632f786f9f76c1f7f929a5 (diff) |
of: thermal: Fix inconsitency between cooling-*-state and cooling-*-level
The device trees in the kernel as well as the binding description in
Documentation/devicetree/bindings/cpufreq/cpufreq-dt.txt use the
cooling-{min,max}-level property.
Fix the inconsistency with the binding description in
Documentation/devicetree/bindings/thermal/thermal.txt by changing
cooling-*-state properties to cooling-*-level.
Signed-off-by: Punit Agrawal <punit.agrawal@arm.com>
Cc: Eduardo Valentin <edubezval@gmail.com>
Cc: Rob Herring <robh+dt@kernel.org>
Cc: Mark Rutland <mark.rutland@arm.com>
Cc: Ian Campbell <ijc+devicetree@hellion.org.uk>
Cc: Kumar Gala <galak@codeaurora.org>
Signed-off-by: Rob Herring <robh@kernel.org>
Diffstat (limited to 'Documentation/devicetree')
-rw-r--r-- | Documentation/devicetree/bindings/thermal/thermal.txt | 14 |
1 files changed, 7 insertions, 7 deletions
diff --git a/Documentation/devicetree/bindings/thermal/thermal.txt b/Documentation/devicetree/bindings/thermal/thermal.txt index 8a49362dea6e..8320186738ff 100644 --- a/Documentation/devicetree/bindings/thermal/thermal.txt +++ b/Documentation/devicetree/bindings/thermal/thermal.txt @@ -55,16 +55,16 @@ of heat dissipation). For example a fan's cooling states correspond to the different fan speeds possible. Cooling states are referred to by single unsigned integers, where larger numbers mean greater heat dissipation. The precise set of cooling states associated with a device -(as referred to be the cooling-min-state and cooling-max-state +(as referred to by the cooling-min-level and cooling-max-level properties) should be defined in a particular device's binding. For more examples of cooling devices, refer to the example sections below. Required properties: -- cooling-min-state: An integer indicating the smallest +- cooling-min-level: An integer indicating the smallest Type: unsigned cooling state accepted. Typically 0. Size: one cell -- cooling-max-state: An integer indicating the largest +- cooling-max-level: An integer indicating the largest Type: unsigned cooling state accepted. Size: one cell @@ -225,8 +225,8 @@ cpus { 396000 950000 198000 850000 >; - cooling-min-state = <0>; - cooling-max-state = <3>; + cooling-min-level = <0>; + cooling-max-level = <3>; #cooling-cells = <2>; /* min followed by max */ }; ... @@ -240,8 +240,8 @@ cpus { */ fan0: fan@0x48 { ... - cooling-min-state = <0>; - cooling-max-state = <9>; + cooling-min-level = <0>; + cooling-max-level = <9>; #cooling-cells = <2>; /* min followed by max */ }; }; |