summaryrefslogtreecommitdiff
path: root/Documentation/devicetree
diff options
context:
space:
mode:
authorPunit Agrawal <punit.agrawal@arm.com>2015-09-08 12:20:48 +0100
committerRob Herring <robh@kernel.org>2015-09-17 14:36:36 -0500
commiteb168b70dea54578a45119fcdb3b48ad5d75fed9 (patch)
tree42f3ff2d9e4e76d2ffb01420753c575c652270ce /Documentation/devicetree
parentdc4dae00d82fedcd7a632f786f9f76c1f7f929a5 (diff)
of: thermal: Fix inconsitency between cooling-*-state and cooling-*-level
The device trees in the kernel as well as the binding description in Documentation/devicetree/bindings/cpufreq/cpufreq-dt.txt use the cooling-{min,max}-level property. Fix the inconsistency with the binding description in Documentation/devicetree/bindings/thermal/thermal.txt by changing cooling-*-state properties to cooling-*-level. Signed-off-by: Punit Agrawal <punit.agrawal@arm.com> Cc: Eduardo Valentin <edubezval@gmail.com> Cc: Rob Herring <robh+dt@kernel.org> Cc: Mark Rutland <mark.rutland@arm.com> Cc: Ian Campbell <ijc+devicetree@hellion.org.uk> Cc: Kumar Gala <galak@codeaurora.org> Signed-off-by: Rob Herring <robh@kernel.org>
Diffstat (limited to 'Documentation/devicetree')
-rw-r--r--Documentation/devicetree/bindings/thermal/thermal.txt14
1 files changed, 7 insertions, 7 deletions
diff --git a/Documentation/devicetree/bindings/thermal/thermal.txt b/Documentation/devicetree/bindings/thermal/thermal.txt
index 8a49362dea6e..8320186738ff 100644
--- a/Documentation/devicetree/bindings/thermal/thermal.txt
+++ b/Documentation/devicetree/bindings/thermal/thermal.txt
@@ -55,16 +55,16 @@ of heat dissipation). For example a fan's cooling states correspond to
the different fan speeds possible. Cooling states are referred to by
single unsigned integers, where larger numbers mean greater heat
dissipation. The precise set of cooling states associated with a device
-(as referred to be the cooling-min-state and cooling-max-state
+(as referred to by the cooling-min-level and cooling-max-level
properties) should be defined in a particular device's binding.
For more examples of cooling devices, refer to the example sections below.
Required properties:
-- cooling-min-state: An integer indicating the smallest
+- cooling-min-level: An integer indicating the smallest
Type: unsigned cooling state accepted. Typically 0.
Size: one cell
-- cooling-max-state: An integer indicating the largest
+- cooling-max-level: An integer indicating the largest
Type: unsigned cooling state accepted.
Size: one cell
@@ -225,8 +225,8 @@ cpus {
396000 950000
198000 850000
>;
- cooling-min-state = <0>;
- cooling-max-state = <3>;
+ cooling-min-level = <0>;
+ cooling-max-level = <3>;
#cooling-cells = <2>; /* min followed by max */
};
...
@@ -240,8 +240,8 @@ cpus {
*/
fan0: fan@0x48 {
...
- cooling-min-state = <0>;
- cooling-max-state = <9>;
+ cooling-min-level = <0>;
+ cooling-max-level = <9>;
#cooling-cells = <2>; /* min followed by max */
};
};