diff options
author | David Daney <david.daney@cavium.com> | 2016-03-11 09:53:11 -0800 |
---|---|---|
committer | David S. Miller <davem@davemloft.net> | 2016-03-14 15:27:22 -0400 |
commit | 379d7ac7ca31722a1fb488ae3e98b274c9db568c (patch) | |
tree | b46597bf328b8a005d607d85e8c3695ce00ea1ab /Documentation/devicetree | |
parent | 1eefee901fca0208b8a56f20cdc134e2b8638ae7 (diff) |
phy: mdio-thunder: Add driver for Cavium Thunder SoC MDIO buses.
The Cavium Thunder SoCs have multiple MIDO buses that are part of a
single PCI device. To model this in the device tree we call the PCI
parent device a "cavium,thunder-8890-mdio-nexus", it has several
children, one for each MDIO bus.
The MDIO bus hardware is identical to that found in the OCTEON SoCs,
so we use that code for things that are not part of the PCI driver
probe/remove
Signed-off-by: David Daney <david.daney@cavium.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'Documentation/devicetree')
-rw-r--r-- | Documentation/devicetree/bindings/net/cavium-mdio.txt | 61 |
1 files changed, 59 insertions, 2 deletions
diff --git a/Documentation/devicetree/bindings/net/cavium-mdio.txt b/Documentation/devicetree/bindings/net/cavium-mdio.txt index 04cb7491d232..020df08b8a30 100644 --- a/Documentation/devicetree/bindings/net/cavium-mdio.txt +++ b/Documentation/devicetree/bindings/net/cavium-mdio.txt @@ -1,9 +1,12 @@ * System Management Interface (SMI) / MDIO Properties: -- compatible: "cavium,octeon-3860-mdio" +- compatible: One of: - Compatibility with all cn3XXX, cn5XXX and cn6XXX SOCs. + "cavium,octeon-3860-mdio": Compatibility with all cn3XXX, cn5XXX + and cn6XXX SOCs. + + "cavium,thunder-8890-mdio": Compatibility with all cn8XXX SOCs. - reg: The base address of the MDIO bus controller register bank. @@ -25,3 +28,57 @@ Example: reg = <0>; }; }; + + +* System Management Interface (SMI) / MDIO Nexus + + Several mdio buses may be gathered as children of a single PCI + device, this PCI device is the nexus of the buses. + +Properties: + +- compatible: "cavium,thunder-8890-mdio-nexus"; + +- reg: The PCI device and function numbers of the nexus device. + +- #address-cells: Must be <2>. + +- #size-cells: Must be <2>. + +- ranges: As needed for mapping of the MDIO bus device registers. + +- assigned-addresses: As needed for mapping of the MDIO bus device registers. + +Example: + + mdio-nexus@1,3 { + compatible = "cavium,thunder-8890-mdio-nexus"; + #address-cells = <2>; + #size-cells = <2>; + reg = <0x0b00 0 0 0 0>; /* DEVFN = 0x0b (1:3) */ + assigned-addresses = <0x03000000 0x87e0 0x05000000 0x0 0x800000>; + ranges = <0x87e0 0x05000000 0x03000000 0x87e0 0x05000000 0x0 0x800000>; + + mdio0@87e0,05003800 { + compatible = "cavium,thunder-8890-mdio"; + #address-cells = <1>; + #size-cells = <0>; + reg = <0x87e0 0x05003800 0x0 0x30>; + + ethernet-phy@0 { + ... + reg = <0>; + }; + }; + mdio0@87e0,05003880 { + compatible = "cavium,thunder-8890-mdio"; + #address-cells = <1>; + #size-cells = <0>; + reg = <0x87e0 0x05003880 0x0 0x30>; + + ethernet-phy@0 { + ... + reg = <0>; + }; + }; + }; |