diff options
author | Sebastian Reichel <sebastian.reichel@collabora.com> | 2021-03-17 14:48:53 +0100 |
---|---|---|
committer | Sebastian Reichel <sre@kernel.org> | 2021-03-23 12:55:23 +0100 |
commit | ee123ad9780b772dedd37aec18e77ae41a69d321 (patch) | |
tree | c651504c6686c04c38e70a14639af98359b7a52c /Documentation/devicetree/bindings/power | |
parent | 6c463222a21dabb51ed5ad7653e605ead5749d64 (diff) |
dt-bindings: power: supply: act8945a: Convert to DT schema format
Convert the binding to DT schema format.
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Reviewed-by: Rob Herring <robh@kernel.org>
Diffstat (limited to 'Documentation/devicetree/bindings/power')
-rw-r--r-- | Documentation/devicetree/bindings/power/supply/act8945a-charger.txt | 44 | ||||
-rw-r--r-- | Documentation/devicetree/bindings/power/supply/active-semi,act8945a-charger.yaml | 76 |
2 files changed, 76 insertions, 44 deletions
diff --git a/Documentation/devicetree/bindings/power/supply/act8945a-charger.txt b/Documentation/devicetree/bindings/power/supply/act8945a-charger.txt deleted file mode 100644 index cb737a9e1f16..000000000000 --- a/Documentation/devicetree/bindings/power/supply/act8945a-charger.txt +++ /dev/null @@ -1,44 +0,0 @@ -Device-Tree bindings for charger of Active-semi ACT8945A Multi-Function Device - -Required properties: - - compatible: "active-semi,act8945a-charger". - - active-semi,chglev-gpios: charge current level phandle with args - as described in ../gpio/gpio.txt. - - active-semi,lbo-gpios: specify the low battery voltage detect phandle - with args as as described in ../gpio/gpio.txt. - - interrupts: <a b> where a is the interrupt number and b is a - field that represents an encoding of the sense and level - information for the interrupt. - -Optional properties: - - active-semi,input-voltage-threshold-microvolt: unit: mV; - Specifies the charger's input over-voltage threshold value; - The value can be: 6600, 7000, 7500, 8000; default: 6600 - - active-semi,precondition-timeout: unit: minutes; - Specifies the charger's PRECONDITION safety timer setting value; - The value can be: 40, 60, 80, 0; If 0, it means to disable this timer; - default: 40. - - active-semi,total-timeout: unit: hours; - Specifies the charger's total safety timer setting value; - The value can be: 3, 4, 5, 0; If 0, it means to disable this timer; - default: 3. - -Example: - pmic@5b { - compatible = "active-semi,act8945a"; - reg = <0x5b>; - - charger { - compatible = "active-semi,act8945a-charger"; - pinctrl-names = "default"; - pinctrl-0 = <&pinctrl_charger_chglev &pinctrl_charger_lbo &pinctrl_charger_irq>; - interrupt-parent = <&pioA>; - interrupts = <45 IRQ_TYPE_LEVEL_LOW>; - - active-semi,chglev-gpios = <&pioA 12 GPIO_ACTIVE_HIGH>; - active-semi,lbo-gpios = <&pioA 72 GPIO_ACTIVE_LOW>; - active-semi,input-voltage-threshold-microvolt = <6600>; - active-semi,precondition-timeout = <40>; - active-semi,total-timeout = <3>; - }; - }; diff --git a/Documentation/devicetree/bindings/power/supply/active-semi,act8945a-charger.yaml b/Documentation/devicetree/bindings/power/supply/active-semi,act8945a-charger.yaml new file mode 100644 index 000000000000..3f74bc19415d --- /dev/null +++ b/Documentation/devicetree/bindings/power/supply/active-semi,act8945a-charger.yaml @@ -0,0 +1,76 @@ +# SPDX-License-Identifier: GPL-2.0 +%YAML 1.2 +--- +$id: "http://devicetree.org/schemas/power/supply/active-semi,act8945a-charger.yaml#" +$schema: "http://devicetree.org/meta-schemas/core.yaml#" + +title: Active-semi ACT8945A Charger Function + +maintainers: + - Sebastian Reichel <sre@kernel.org> + +allOf: + - $ref: power-supply.yaml# + +properties: + compatible: + const: active-semi,act8945a-charger + + interrupts: + maxItems: 1 + + active-semi,chglev-gpios: + maxItems: 1 + description: charge current level GPIO + + active-semi,lbo-gpios: + maxItems: 1 + description: low battery voltage detect GPIO + + active-semi,input-voltage-threshold-microvolt: + description: | + Specifies the charger's input over-voltage threshold value. + Despite the name, specified values are in millivolt (mV). + Defaults to 6.6 V + enum: [ 6600, 7000, 7500, 8000 ] + + active-semi,precondition-timeout: + $ref: /schemas/types.yaml#/definitions/uint32 + description: | + Specifies the charger's PRECONDITION safety timer setting value in minutes. + If 0, it means to disable this timer. + Defaults to 40 minutes. + enum: [ 0, 40, 60, 80 ] + + active-semi,total-timeout: + $ref: /schemas/types.yaml#/definitions/uint32 + description: | + Specifies the charger's total safety timer setting value in hours; + If 0, it means to disable this timer; + Defaults to 3 hours. + enum: [ 0, 3, 4, 5 ] + +required: + - compatible + - interrupts + - active-semi,chglev-gpios + - active-semi,lbo-gpios + +additionalProperties: false + +examples: + - | + #include <dt-bindings/gpio/gpio.h> + #include <dt-bindings/interrupt-controller/irq.h> + pmic { + charger { + compatible = "active-semi,act8945a-charger"; + interrupt-parent = <&pioA>; + interrupts = <45 IRQ_TYPE_LEVEL_LOW>; + active-semi,chglev-gpios = <&pioA 12 GPIO_ACTIVE_HIGH>; + active-semi,lbo-gpios = <&pioA 72 GPIO_ACTIVE_LOW>; + active-semi,input-voltage-threshold-microvolt = <6600>; + active-semi,precondition-timeout = <40>; + active-semi,total-timeout = <3>; + }; + }; |