summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorMaxim Kochetkov <fido_max@inbox.ru>2021-04-22 13:46:43 +0300
committerDavid S. Miller <davem@davemloft.net>2021-04-22 13:20:39 -0700
commit990875b299b8612aeb85cb2e2751796f1add65ff (patch)
tree343c3de3ca91361f9fdc5002748585e7739302f9
parenteefb45eef5c4c425e87667af8f5e904fbdd47abf (diff)
net: phy: marvell: fix m88e1011_set_downshift
Changing downshift params without software reset has no effect, so call genphy_soft_reset() after change downshift params. As the datasheet says: Changes to these bits are disruptive to the normal operation therefore, any changes to these registers must be followed by software reset to take effect. Fixes: 911af5e149bb ("net: phy: marvell: fix downshift function naming") Signed-off-by: Maxim Kochetkov <fido_max@inbox.ru> Reviewed-by: Andrew Lunn <andrew@lunn.ch> Signed-off-by: David S. Miller <davem@davemloft.net>
-rw-r--r--drivers/net/phy/marvell.c26
1 files changed, 16 insertions, 10 deletions
diff --git a/drivers/net/phy/marvell.c b/drivers/net/phy/marvell.c
index 8018ddf7f316..723f25f6138d 100644
--- a/drivers/net/phy/marvell.c
+++ b/drivers/net/phy/marvell.c
@@ -1025,22 +1025,28 @@ static int m88e1011_get_downshift(struct phy_device *phydev, u8 *data)
static int m88e1011_set_downshift(struct phy_device *phydev, u8 cnt)
{
- int val;
+ int val, err;
if (cnt > MII_M1011_PHY_SCR_DOWNSHIFT_MAX)
return -E2BIG;
- if (!cnt)
- return phy_clear_bits(phydev, MII_M1011_PHY_SCR,
- MII_M1011_PHY_SCR_DOWNSHIFT_EN);
+ if (!cnt) {
+ err = phy_clear_bits(phydev, MII_M1011_PHY_SCR,
+ MII_M1011_PHY_SCR_DOWNSHIFT_EN);
+ } else {
+ val = MII_M1011_PHY_SCR_DOWNSHIFT_EN;
+ val |= FIELD_PREP(MII_M1011_PHY_SCR_DOWNSHIFT_MASK, cnt - 1);
- val = MII_M1011_PHY_SCR_DOWNSHIFT_EN;
- val |= FIELD_PREP(MII_M1011_PHY_SCR_DOWNSHIFT_MASK, cnt - 1);
+ err = phy_modify(phydev, MII_M1011_PHY_SCR,
+ MII_M1011_PHY_SCR_DOWNSHIFT_EN |
+ MII_M1011_PHY_SCR_DOWNSHIFT_MASK,
+ val);
+ }
- return phy_modify(phydev, MII_M1011_PHY_SCR,
- MII_M1011_PHY_SCR_DOWNSHIFT_EN |
- MII_M1011_PHY_SCR_DOWNSHIFT_MASK,
- val);
+ if (err < 0)
+ return err;
+
+ return genphy_soft_reset(phydev);
}
static int m88e1011_get_tunable(struct phy_device *phydev,