summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorLucas Stach <l.stach@pengutronix.de>2020-09-30 10:40:47 +0200
committerSebastian Reichel <sebastian.reichel@collabora.com>2020-10-01 00:18:05 +0200
commit81196e2e57fc5b88f6b8ca98372a3dde047aa49d (patch)
tree0fd685763f63cc1e45821a98bcaa732c3cced176
parent3c8b5fb9983b7c7eb2e3557d687a3613288e0780 (diff)
power: supply: ucs1002: fix some health status issues
Some fault events like the over-current condition will get resolved by the hardware, by e.g. disabling the port. As the status in the interrupt status register is cleared on read when the fault is resolved, the sysfs health property will only contain the correct health status for the first time it is read after such an event, even if the actual fault condition (like a VBUS short) still persists. To reflect this properly in the property we cache the last health status and only update the cache when a actual change happens, i.e. the ERR bit in the status register flips, as this one properly reflects a continued fault condition. The ALERT pin however, is not driven by the ERR status, but by the actual fault status, so the pin will change back to it's default state when the hardware has automatically resolved the fault by cutting the power. Thus we never get an IRQ when the actual fault condition has been resolved and the ERR status bit has been cleared in auto-recovery mode. To get this information we need to poll the interrupt status register after some time to see if the fault is gone and update our cache in that case. To avoid any additional locking, we handle both paths (IRQ firing and delayed polling) through the same single-threaded delayed work. Signed-off-by: Lucas Stach <l.stach@pengutronix.de> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
-rw-r--r--drivers/power/supply/ucs1002_power.c75
1 files changed, 43 insertions, 32 deletions
diff --git a/drivers/power/supply/ucs1002_power.c b/drivers/power/supply/ucs1002_power.c
index cdb9a23d825f..ef673ec3db56 100644
--- a/drivers/power/supply/ucs1002_power.c
+++ b/drivers/power/supply/ucs1002_power.c
@@ -38,6 +38,7 @@
/* Interrupt Status */
#define UCS1002_REG_INTERRUPT_STATUS 0x10
+# define F_ERR BIT(7)
# define F_DISCHARGE_ERR BIT(6)
# define F_RESET BIT(5)
# define F_MIN_KEEP_OUT BIT(4)
@@ -103,6 +104,9 @@ struct ucs1002_info {
struct regulator_dev *rdev;
bool present;
bool output_disable;
+ struct delayed_work health_poll;
+ int health;
+
};
static enum power_supply_property ucs1002_props[] = {
@@ -362,32 +366,6 @@ static int ucs1002_get_usb_type(struct ucs1002_info *info,
return 0;
}
-static int ucs1002_get_health(struct ucs1002_info *info,
- union power_supply_propval *val)
-{
- unsigned int reg;
- int ret, health;
-
- ret = regmap_read(info->regmap, UCS1002_REG_INTERRUPT_STATUS, &reg);
- if (ret)
- return ret;
-
- if (reg & F_TSD)
- health = POWER_SUPPLY_HEALTH_OVERHEAT;
- else if (reg & (F_OVER_VOLT | F_BACK_VOLT))
- health = POWER_SUPPLY_HEALTH_OVERVOLTAGE;
- else if (reg & F_OVER_ILIM)
- health = POWER_SUPPLY_HEALTH_OVERCURRENT;
- else if (reg & (F_DISCHARGE_ERR | F_MIN_KEEP_OUT))
- health = POWER_SUPPLY_HEALTH_UNSPEC_FAILURE;
- else
- health = POWER_SUPPLY_HEALTH_GOOD;
-
- val->intval = health;
-
- return 0;
-}
-
static int ucs1002_get_property(struct power_supply *psy,
enum power_supply_property psp,
union power_supply_propval *val)
@@ -406,7 +384,7 @@ static int ucs1002_get_property(struct power_supply *psy,
case POWER_SUPPLY_PROP_USB_TYPE:
return ucs1002_get_usb_type(info, val);
case POWER_SUPPLY_PROP_HEALTH:
- return ucs1002_get_health(info, val);
+ return val->intval = info->health;
case POWER_SUPPLY_PROP_PRESENT:
val->intval = info->present;
return 0;
@@ -458,6 +436,38 @@ static const struct power_supply_desc ucs1002_charger_desc = {
.num_properties = ARRAY_SIZE(ucs1002_props),
};
+static void ucs1002_health_poll(struct work_struct *work)
+{
+ struct ucs1002_info *info = container_of(work, struct ucs1002_info,
+ health_poll.work);
+ int ret;
+ u32 reg;
+
+ ret = regmap_read(info->regmap, UCS1002_REG_INTERRUPT_STATUS, &reg);
+ if (ret)
+ return;
+
+ /* bad health and no status change, just schedule us again in a while */
+ if ((reg & F_ERR) && info->health != POWER_SUPPLY_HEALTH_GOOD) {
+ schedule_delayed_work(&info->health_poll,
+ msecs_to_jiffies(2000));
+ return;
+ }
+
+ if (reg & F_TSD)
+ info->health = POWER_SUPPLY_HEALTH_OVERHEAT;
+ else if (reg & (F_OVER_VOLT | F_BACK_VOLT))
+ info->health = POWER_SUPPLY_HEALTH_OVERVOLTAGE;
+ else if (reg & F_OVER_ILIM)
+ info->health = POWER_SUPPLY_HEALTH_OVERCURRENT;
+ else if (reg & (F_DISCHARGE_ERR | F_MIN_KEEP_OUT))
+ info->health = POWER_SUPPLY_HEALTH_UNSPEC_FAILURE;
+ else
+ info->health = POWER_SUPPLY_HEALTH_GOOD;
+
+ sysfs_notify(&info->charger->dev.kobj, NULL, "health");
+}
+
static irqreturn_t ucs1002_charger_irq(int irq, void *data)
{
int ret, regval;
@@ -484,7 +494,7 @@ static irqreturn_t ucs1002_alert_irq(int irq, void *data)
{
struct ucs1002_info *info = data;
- power_supply_changed(info->charger);
+ mod_delayed_work(system_wq, &info->health_poll, 0);
return IRQ_HANDLED;
}
@@ -632,6 +642,9 @@ static int ucs1002_probe(struct i2c_client *client,
return ret;
}
+ info->health = POWER_SUPPLY_HEALTH_GOOD;
+ INIT_DELAYED_WORK(&info->health_poll, ucs1002_health_poll);
+
if (irq_a_det > 0) {
ret = devm_request_threaded_irq(dev, irq_a_det, NULL,
ucs1002_charger_irq,
@@ -645,10 +658,8 @@ static int ucs1002_probe(struct i2c_client *client,
}
if (irq_alert > 0) {
- ret = devm_request_threaded_irq(dev, irq_alert, NULL,
- ucs1002_alert_irq,
- IRQF_ONESHOT,
- "ucs1002-alert", info);
+ ret = devm_request_irq(dev, irq_alert, ucs1002_alert_irq,
+ 0,"ucs1002-alert", info);
if (ret) {
dev_err(dev, "Failed to request ALERT threaded irq: %d\n",
ret);