summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorMike Miller <mike.miller@hp.com>2010-12-01 11:16:07 -0600
committerJames Bottomley <James.Bottomley@suse.de>2010-12-09 15:06:50 -0600
commit7c03b87048f2467087ae7e51392e5fb57ea8f58b (patch)
tree46bca361c5acaa7d9dc2c13376a52a2058feab9f
parent13d38d9df26b5b9a5ad5f9fbc065078bc42a8748 (diff)
[SCSI] hpsa: fix redefinition of PCI_DEVICE_ID_CISSF
PCI_DEVICE_ID_CISSF is defined as 323b in pci_ids.h but redefined as 3fff in hpsa.c. The ID of 3fff will _never_ ship as a standalone controller. It is intended only as part a complete storage solution. As such, this patch removes the redefinition and the StorageWorks P1210m from the product table. It also removes a duplicate line for the "unknown" controller support. Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-rw-r--r--drivers/scsi/hpsa.c8
1 files changed, 1 insertions, 7 deletions
diff --git a/drivers/scsi/hpsa.c b/drivers/scsi/hpsa.c
index b2fb2b2a6e70..a6dea08664fc 100644
--- a/drivers/scsi/hpsa.c
+++ b/drivers/scsi/hpsa.c
@@ -90,11 +90,7 @@ static const struct pci_device_id hpsa_pci_device_id[] = {
{PCI_VENDOR_ID_HP, PCI_DEVICE_ID_HP_CISSE, 0x103C, 0x3252},
{PCI_VENDOR_ID_HP, PCI_DEVICE_ID_HP_CISSE, 0x103C, 0x3253},
{PCI_VENDOR_ID_HP, PCI_DEVICE_ID_HP_CISSE, 0x103C, 0x3254},
-#define PCI_DEVICE_ID_HP_CISSF 0x333f
- {PCI_VENDOR_ID_HP, PCI_DEVICE_ID_HP_CISSF, 0x103C, 0x333F},
- {PCI_VENDOR_ID_HP, PCI_ANY_ID, PCI_ANY_ID, PCI_ANY_ID,
- PCI_CLASS_STORAGE_RAID << 8, 0xffff << 8, 0},
- {PCI_VENDOR_ID_COMPAQ, PCI_ANY_ID, PCI_ANY_ID, PCI_ANY_ID,
+ {PCI_VENDOR_ID_HP, PCI_ANY_ID, PCI_ANY_ID, PCI_ANY_ID,
PCI_CLASS_STORAGE_RAID << 8, 0xffff << 8, 0},
{0,}
};
@@ -113,8 +109,6 @@ static struct board_type products[] = {
{0x3249103C, "Smart Array P812", &SA5_access},
{0x324a103C, "Smart Array P712m", &SA5_access},
{0x324b103C, "Smart Array P711m", &SA5_access},
- {0x3233103C, "StorageWorks P1210m", &SA5_access},
- {0x333F103C, "StorageWorks P1210m", &SA5_access},
{0x3250103C, "Smart Array", &SA5_access},
{0x3250113C, "Smart Array", &SA5_access},
{0x3250123C, "Smart Array", &SA5_access},