diff options
author | Linus Torvalds <torvalds@linux-foundation.org> | 2015-08-20 11:32:33 -0700 |
---|---|---|
committer | Linus Torvalds <torvalds@linux-foundation.org> | 2015-08-20 11:32:33 -0700 |
commit | 3bd8f7d87dd12a97f0215f0d1a4afdd20ba49854 (patch) | |
tree | 029e0090e05f3b36b58f942f12f6e5f93a2cc7cf | |
parent | 1b647a166f07dcf08709c8606470f4b17a4aa11d (diff) | |
parent | 1afb9c539daebc2c8a7b33d0e0b8fc9f74671b02 (diff) |
Merge branch 'fixes' of git://git.kernel.org/pub/scm/linux/kernel/git/evalenti/linux-soc-thermal
Pull thermal fixes from Eduardo Valentin:
"Last minute fixes on the thermal-soc tree. There is a fix of a long
lasting bug in cpu cooling device, thanks for RMK for being pushing
this"
* 'fixes' of git://git.kernel.org/pub/scm/linux/kernel/git/evalenti/linux-soc-thermal:
thermal/cpu_cooling: update policy limits if clipped_freq < policy->max
thermal/cpu_cooling: rename max_freq as clipped_freq in notifier
thermal/cpu_cooling: rename cpufreq_val as clipped_freq
thermal/cpu_cooling: convert 'switch' block to 'if' block in notifier
thermal/cpu_cooling: quit early after updating policy
thermal/cpu_cooling: No need to initialize max_freq to 0
thermal: cpu_cooling: fix lockdep problems in cpu_cooling
thermal: power_allocator: do not use devm* interfaces
-rw-r--r-- | drivers/thermal/cpu_cooling.c | 73 | ||||
-rw-r--r-- | drivers/thermal/power_allocator.c | 8 |
2 files changed, 48 insertions, 33 deletions
diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c index 6509c61b9648..620dcd405ff6 100644 --- a/drivers/thermal/cpu_cooling.c +++ b/drivers/thermal/cpu_cooling.c @@ -68,7 +68,7 @@ struct power_table { * registered cooling device. * @cpufreq_state: integer value representing the current state of cpufreq * cooling devices. - * @cpufreq_val: integer value representing the absolute value of the clipped + * @clipped_freq: integer value representing the absolute value of the clipped * frequency. * @max_level: maximum cooling level. One less than total number of valid * cpufreq frequencies. @@ -91,7 +91,7 @@ struct cpufreq_cooling_device { int id; struct thermal_cooling_device *cool_dev; unsigned int cpufreq_state; - unsigned int cpufreq_val; + unsigned int clipped_freq; unsigned int max_level; unsigned int *freq_table; /* In descending order */ struct cpumask allowed_cpus; @@ -107,6 +107,9 @@ struct cpufreq_cooling_device { static DEFINE_IDR(cpufreq_idr); static DEFINE_MUTEX(cooling_cpufreq_lock); +static unsigned int cpufreq_dev_count; + +static DEFINE_MUTEX(cooling_list_lock); static LIST_HEAD(cpufreq_dev_list); /** @@ -185,14 +188,14 @@ unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq) { struct cpufreq_cooling_device *cpufreq_dev; - mutex_lock(&cooling_cpufreq_lock); + mutex_lock(&cooling_list_lock); list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) { if (cpumask_test_cpu(cpu, &cpufreq_dev->allowed_cpus)) { - mutex_unlock(&cooling_cpufreq_lock); + mutex_unlock(&cooling_list_lock); return get_level(cpufreq_dev, freq); } } - mutex_unlock(&cooling_cpufreq_lock); + mutex_unlock(&cooling_list_lock); pr_err("%s: cpu:%d not part of any cooling device\n", __func__, cpu); return THERMAL_CSTATE_INVALID; @@ -215,29 +218,35 @@ static int cpufreq_thermal_notifier(struct notifier_block *nb, unsigned long event, void *data) { struct cpufreq_policy *policy = data; - unsigned long max_freq = 0; + unsigned long clipped_freq; struct cpufreq_cooling_device *cpufreq_dev; - switch (event) { + if (event != CPUFREQ_ADJUST) + return NOTIFY_DONE; - case CPUFREQ_ADJUST: - mutex_lock(&cooling_cpufreq_lock); - list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) { - if (!cpumask_test_cpu(policy->cpu, - &cpufreq_dev->allowed_cpus)) - continue; + mutex_lock(&cooling_list_lock); + list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) { + if (!cpumask_test_cpu(policy->cpu, &cpufreq_dev->allowed_cpus)) + continue; - max_freq = cpufreq_dev->cpufreq_val; + /* + * policy->max is the maximum allowed frequency defined by user + * and clipped_freq is the maximum that thermal constraints + * allow. + * + * If clipped_freq is lower than policy->max, then we need to + * readjust policy->max. + * + * But, if clipped_freq is greater than policy->max, we don't + * need to do anything. + */ + clipped_freq = cpufreq_dev->clipped_freq; - if (policy->max != max_freq) - cpufreq_verify_within_limits(policy, 0, - max_freq); - } - mutex_unlock(&cooling_cpufreq_lock); + if (policy->max > clipped_freq) + cpufreq_verify_within_limits(policy, 0, clipped_freq); break; - default: - return NOTIFY_DONE; } + mutex_unlock(&cooling_list_lock); return NOTIFY_OK; } @@ -519,7 +528,7 @@ static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev, clip_freq = cpufreq_device->freq_table[state]; cpufreq_device->cpufreq_state = state; - cpufreq_device->cpufreq_val = clip_freq; + cpufreq_device->clipped_freq = clip_freq; cpufreq_update_policy(cpu); @@ -861,17 +870,19 @@ __cpufreq_cooling_register(struct device_node *np, pr_debug("%s: freq:%u KHz\n", __func__, freq); } - cpufreq_dev->cpufreq_val = cpufreq_dev->freq_table[0]; + cpufreq_dev->clipped_freq = cpufreq_dev->freq_table[0]; cpufreq_dev->cool_dev = cool_dev; mutex_lock(&cooling_cpufreq_lock); + mutex_lock(&cooling_list_lock); + list_add(&cpufreq_dev->node, &cpufreq_dev_list); + mutex_unlock(&cooling_list_lock); + /* Register the notifier for first cpufreq cooling device */ - if (list_empty(&cpufreq_dev_list)) + if (!cpufreq_dev_count++) cpufreq_register_notifier(&thermal_cpufreq_notifier_block, CPUFREQ_POLICY_NOTIFIER); - list_add(&cpufreq_dev->node, &cpufreq_dev_list); - mutex_unlock(&cooling_cpufreq_lock); return cool_dev; @@ -1013,13 +1024,17 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev) return; cpufreq_dev = cdev->devdata; - mutex_lock(&cooling_cpufreq_lock); - list_del(&cpufreq_dev->node); /* Unregister the notifier for the last cpufreq cooling device */ - if (list_empty(&cpufreq_dev_list)) + mutex_lock(&cooling_cpufreq_lock); + if (!--cpufreq_dev_count) cpufreq_unregister_notifier(&thermal_cpufreq_notifier_block, CPUFREQ_POLICY_NOTIFIER); + + mutex_lock(&cooling_list_lock); + list_del(&cpufreq_dev->node); + mutex_unlock(&cooling_list_lock); + mutex_unlock(&cooling_cpufreq_lock); thermal_cooling_device_unregister(cpufreq_dev->cool_dev); diff --git a/drivers/thermal/power_allocator.c b/drivers/thermal/power_allocator.c index 63a448f9d93b..7006860f2f36 100644 --- a/drivers/thermal/power_allocator.c +++ b/drivers/thermal/power_allocator.c @@ -334,7 +334,7 @@ static int allocate_power(struct thermal_zone_device *tz, max_allocatable_power, current_temp, (s32)control_temp - (s32)current_temp); - devm_kfree(&tz->device, req_power); + kfree(req_power); unlock: mutex_unlock(&tz->lock); @@ -426,7 +426,7 @@ static int power_allocator_bind(struct thermal_zone_device *tz) return -EINVAL; } - params = devm_kzalloc(&tz->device, sizeof(*params), GFP_KERNEL); + params = kzalloc(sizeof(*params), GFP_KERNEL); if (!params) return -ENOMEM; @@ -468,14 +468,14 @@ static int power_allocator_bind(struct thermal_zone_device *tz) return 0; free: - devm_kfree(&tz->device, params); + kfree(params); return ret; } static void power_allocator_unbind(struct thermal_zone_device *tz) { dev_dbg(&tz->device, "Unbinding from thermal zone %d\n", tz->id); - devm_kfree(&tz->device, tz->governor_data); + kfree(tz->governor_data); tz->governor_data = NULL; } |