# EN11 incremental encoder sensor configuration options # Copyright (c) 2020 Peter Johanson # SPDX-License-Identifier: MIT menuconfig EN11 bool "EN11 Incremental Encoder Sensor" depends on GPIO help Enable driver for EN11 incremental encoder sensors. if EN11 choice prompt "Trigger mode" default EN11_TRIGGER_NONE help Specify the type of triggering to be used by the driver. config EN11_TRIGGER_NONE bool "No trigger" config EN11_TRIGGER_GLOBAL_THREAD bool "Use global thread" depends on GPIO select EN11_TRIGGER config EN11_TRIGGER_OWN_THREAD bool "Use own thread" depends on GPIO select EN11_TRIGGER endchoice config EN11_TRIGGER bool config EN11_THREAD_PRIORITY int "Thread priority" depends on EN11_TRIGGER_OWN_THREAD default 10 help Priority of thread used by the driver to handle interrupts. config EN11_THREAD_STACK_SIZE int "Thread stack size" depends on EN11_TRIGGER_OWN_THREAD default 1024 help Stack size of thread used by the driver to handle interrupts. endif # EN11