From f0774d41da0e607b70e54ecc50aeb6684f54c2b1 Mon Sep 17 00:00:00 2001 From: Heiko Stuebner Date: Thu, 4 Apr 2013 14:55:10 +0900 Subject: irqchip: s3c24xx: add devicetree support Add the necessary code to initialize the interrupt controller thru devicetree data using the irqchip infrastructure. Signed-off-by: Heiko Stuebner Acked-by: Arnd Bergmann Acked-by: Rob Herring Signed-off-by: Kukjin Kim --- .../interrupt-controller/samsung,s3c24xx-irq.txt | 53 ++++++++++++++++++++++ 1 file changed, 53 insertions(+) create mode 100644 Documentation/devicetree/bindings/interrupt-controller/samsung,s3c24xx-irq.txt (limited to 'Documentation/devicetree') diff --git a/Documentation/devicetree/bindings/interrupt-controller/samsung,s3c24xx-irq.txt b/Documentation/devicetree/bindings/interrupt-controller/samsung,s3c24xx-irq.txt new file mode 100644 index 000000000000..c54c5a9a2a90 --- /dev/null +++ b/Documentation/devicetree/bindings/interrupt-controller/samsung,s3c24xx-irq.txt @@ -0,0 +1,53 @@ +Samsung S3C24XX Interrupt Controllers + +The S3C24XX SoCs contain a custom set of interrupt controllers providing a +varying number of interrupt sources. The set consists of a main- and sub- +controller and on newer SoCs even a second main controller. + +Required properties: +- compatible: Compatible property value should be "samsung,s3c2410-irq" + for machines before s3c2416 and "samsung,s3c2416-irq" for s3c2416 and later. + +- reg: Physical base address of the controller and length of memory mapped + region. + +- interrupt-controller : Identifies the node as an interrupt controller + +- #interrupt-cells : Specifies the number of cells needed to encode an + interrupt source. The value shall be 4 and interrupt descriptor shall + have the following format: + + + ctrl_num contains the controller to use: + - 0 ... main controller + - 1 ... sub controller + - 2 ... second main controller on s3c2416 and s3c2450 + parent_irq contains the parent bit in the main controller and will be + ignored in main controllers + ctrl_irq contains the interrupt bit of the controller + type contains the trigger type to use + +Example: + + interrupt-controller@4a000000 { + compatible = "samsung,s3c2410-irq"; + reg = <0x4a000000 0x100>; + interrupt-controller; + #interrupt-cells=<4>; + }; + + [...] + + serial@50000000 { + compatible = "samsung,s3c2410-uart"; + reg = <0x50000000 0x4000>; + interrupt-parent = <&subintc>; + interrupts = <1 28 0 4>, <1 28 1 4>; + }; + + rtc@57000000 { + compatible = "samsung,s3c2410-rtc"; + reg = <0x57000000 0x100>; + interrupt-parent = <&intc>; + interrupts = <0 30 0 3>, <0 8 0 3>; + }; -- cgit v1.2.3