summaryrefslogtreecommitdiff
path: root/net/smc/smc_pnet.h
AgeCommit message (Collapse)Author
2018-07-25net/smc: use correct vlan gid of RoCE deviceUrsula Braun
SMC code uses the base gid for VLAN traffic. The gids exchanged in the CLC handshake and the gid index used for the QP have to switch from the base gid to the appropriate vlan gid. When searching for a matching IB device port for a certain vlan device, it does not make sense to return an IB device port, which is not enabled for the used vlan_id. Add another check whether a vlan gid exists for a certain IB device port. Signed-off-by: Ursula Braun <ubraun@linux.ibm.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2018-06-30net/smc: add pnetid support for SMC-D and ISMHans Wippel
SMC-D relies on PNETIDs to find usable SMC-D/ISM devices for a SMC connection. This patch adds SMC-D/ISM support to the current PNETID implementation. Signed-off-by: Hans Wippel <hwippel@linux.ibm.com> Signed-off-by: Ursula Braun <ubraun@linux.ibm.com> Suggested-by: Thomas Richter <tmricht@linux.ibm.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2018-06-30net/smc: add pnetid supportUrsula Braun
s390 hardware supports the definition of a so-call Physical NETwork IDentifier (short PNETID) per network device port. These PNETIDS can be used to identify network devices that are attached to the same physical network (broadcast domain). On s390 try to use the PNETID of the ethernet device port used for initial connecting, and derive the IB device port used for SMC RDMA traffic. On platforms without PNETID support fall back to the existing solution of a configured pnet table. Signed-off-by: Ursula Braun <ubraun@linux.ibm.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2017-11-02License cleanup: add SPDX GPL-2.0 license identifier to files with no licenseGreg Kroah-Hartman
Many source files in the tree are missing licensing information, which makes it harder for compliance tools to determine the correct license. By default all files without license information are under the default license of the kernel, which is GPL version 2. Update the files which contain no license information with the 'GPL-2.0' SPDX license identifier. The SPDX identifier is a legally binding shorthand, which can be used instead of the full boiler plate text. This patch is based on work done by Thomas Gleixner and Kate Stewart and Philippe Ombredanne. How this work was done: Patches were generated and checked against linux-4.14-rc6 for a subset of the use cases: - file had no licensing information it it. - file was a */uapi/* one with no licensing information in it, - file was a */uapi/* one with existing licensing information, Further patches will be generated in subsequent months to fix up cases where non-standard license headers were used, and references to license had to be inferred by heuristics based on keywords. The analysis to determine which SPDX License Identifier to be applied to a file was done in a spreadsheet of side by side results from of the output of two independent scanners (ScanCode & Windriver) producing SPDX tag:value files created by Philippe Ombredanne. Philippe prepared the base worksheet, and did an initial spot review of a few 1000 files. The 4.13 kernel was the starting point of the analysis with 60,537 files assessed. Kate Stewart did a file by file comparison of the scanner results in the spreadsheet to determine which SPDX license identifier(s) to be applied to the file. She confirmed any determination that was not immediately clear with lawyers working with the Linux Foundation. Criteria used to select files for SPDX license identifier tagging was: - Files considered eligible had to be source code files. - Make and config files were included as candidates if they contained >5 lines of source - File already had some variant of a license header in it (even if <5 lines). All documentation files were explicitly excluded. The following heuristics were used to determine which SPDX license identifiers to apply. - when both scanners couldn't find any license traces, file was considered to have no license information in it, and the top level COPYING file license applied. For non */uapi/* files that summary was: SPDX license identifier # files ---------------------------------------------------|------- GPL-2.0 11139 and resulted in the first patch in this series. If that file was a */uapi/* path one, it was "GPL-2.0 WITH Linux-syscall-note" otherwise it was "GPL-2.0". Results of that was: SPDX license identifier # files ---------------------------------------------------|------- GPL-2.0 WITH Linux-syscall-note 930 and resulted in the second patch in this series. - if a file had some form of licensing information in it, and was one of the */uapi/* ones, it was denoted with the Linux-syscall-note if any GPL family license was found in the file or had no licensing in it (per prior point). Results summary: SPDX license identifier # files ---------------------------------------------------|------ GPL-2.0 WITH Linux-syscall-note 270 GPL-2.0+ WITH Linux-syscall-note 169 ((GPL-2.0 WITH Linux-syscall-note) OR BSD-2-Clause) 21 ((GPL-2.0 WITH Linux-syscall-note) OR BSD-3-Clause) 17 LGPL-2.1+ WITH Linux-syscall-note 15 GPL-1.0+ WITH Linux-syscall-note 14 ((GPL-2.0+ WITH Linux-syscall-note) OR BSD-3-Clause) 5 LGPL-2.0+ WITH Linux-syscall-note 4 LGPL-2.1 WITH Linux-syscall-note 3 ((GPL-2.0 WITH Linux-syscall-note) OR MIT) 3 ((GPL-2.0 WITH Linux-syscall-note) AND MIT) 1 and that resulted in the third patch in this series. - when the two scanners agreed on the detected license(s), that became the concluded license(s). - when there was disagreement between the two scanners (one detected a license but the other didn't, or they both detected different licenses) a manual inspection of the file occurred. - In most cases a manual inspection of the information in the file resulted in a clear resolution of the license that should apply (and which scanner probably needed to revisit its heuristics). - When it was not immediately clear, the license identifier was confirmed with lawyers working with the Linux Foundation. - If there was any question as to the appropriate license identifier, the file was flagged for further research and to be revisited later in time. In total, over 70 hours of logged manual review was done on the spreadsheet to determine the SPDX license identifiers to apply to the source files by Kate, Philippe, Thomas and, in some cases, confirmation by lawyers working with the Linux Foundation. Kate also obtained a third independent scan of the 4.13 code base from FOSSology, and compared selected files where the other two scanners disagreed against that SPDX file, to see if there was new insights. The Windriver scanner is based on an older version of FOSSology in part, so they are related. Thomas did random spot checks in about 500 files from the spreadsheets for the uapi headers and agreed with SPDX license identifier in the files he inspected. For the non-uapi files Thomas did random spot checks in about 15000 files. In initial set of patches against 4.14-rc6, 3 files were found to have copy/paste license identifier errors, and have been fixed to reflect the correct identifier. Additionally Philippe spent 10 hours this week doing a detailed manual inspection and review of the 12,461 patched files from the initial patch version early this week with: - a full scancode scan run, collecting the matched texts, detected license ids and scores - reviewing anything where there was a license detected (about 500+ files) to ensure that the applied SPDX license was correct - reviewing anything where there was no detection but the patch license was not GPL-2.0 WITH Linux-syscall-note to ensure that the applied SPDX license was correct This produced a worksheet with 20 files needing minor correction. This worksheet was then exported into 3 different .csv files for the different types of files to be modified. These .csv files were then reviewed by Greg. Thomas wrote a script to parse the csv files and add the proper SPDX tag to the file, in the format that the file expected. This script was further refined by Greg based on the output to detect more types of files automatically and to distinguish between header and source .c files (which need different comment types.) Finally Greg ran the script using the .csv files to generate the patches. Reviewed-by: Kate Stewart <kstewart@linuxfoundation.org> Reviewed-by: Philippe Ombredanne <pombredanne@nexb.com> Reviewed-by: Thomas Gleixner <tglx@linutronix.de> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2017-04-11net/smc: remove useless smc_ib_devices_list checkUrsula Braun
The global event handler is created only, if the ib_device has already been used by at least one link group. It is guaranteed that there exists the corresponding entry in the smc_ib_devices list. Get rid of this superfluous check. Signed-off-by: Ursula Braun <ubraun@linux.vnet.ibm.com> Reviewed-by: Thomas Richter <tmricht@linux.vnet.ibm.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2017-01-09smc: establish pnet table managementThomas Richter
Connection creation with SMC-R starts through an internal TCP-connection. The Ethernet interface for this TCP-connection is not restricted to the Ethernet interface of a RoCE device. Any existing Ethernet interface belonging to the same physical net can be used, as long as there is a defined relation between the Ethernet interface and some RoCE devices. This relation is defined with the help of an identification string called "Physical Net ID" or short "pnet ID". Information about defined pnet IDs and their related Ethernet interfaces and RoCE devices is stored in the SMC-R pnet table. A pnet table entry consists of the identifying pnet ID and the associated network and IB device. This patch adds pnet table configuration support using the generic netlink message interface referring to network and IB device by their names. Commands exist to add, delete, and display pnet table entries, and to flush or display the entire pnet table. There are cross-checks to verify whether the ethernet interfaces or infiniband devices really exist in the system. If either device is not available, the pnet ID entry is not created. Loss of network devices and IB devices is also monitored; a pnet ID entry is removed when an associated network or IB device is removed. Signed-off-by: Thomas Richter <tmricht@linux.vnet.ibm.com> Signed-off-by: Ursula Braun <ubraun@linux.vnet.ibm.com> Signed-off-by: David S. Miller <davem@davemloft.net>