Age | Commit message (Collapse) | Author |
|
The Intel xway phys offer the possibility to deactivate the integrated
LED function and to control the LEDs manually.
If this was set by the bootloader, it must be ensured that the
integrated LED function is enabled for all LEDs when loading the driver.
Before commit 6e2d85ec0559 ("net: phy: Stop with excessive soft reset")
the LEDs were enabled by a soft-reset of the PHY (using
genphy_soft_reset). Initialize the XWAY_MDIO_LED with it's default
value (which is applied during a soft reset) instead of adding back
the soft reset. This brings back the default LED configuration while
still preventing an excessive amount of soft resets.
Fixes: 6e2d85ec0559 ("net: phy: Stop with excessive soft reset")
Signed-off-by: Martin Schiller <ms@dev.tdt.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
In preparation of removing the .ack_interrupt() callback, we must replace
its occurrences (aka phy_clear_interrupt), from the 2 places where it is
called from (phy_enable_interrupts and phy_disable_interrupts), with
equivalent functionality.
This means that clearing interrupts now becomes something that the PHY
driver is responsible of doing, before enabling interrupts and after
clearing them. Make this driver follow the new contract.
Cc: Mathias Kresin <dev@kresin.me>
Cc: Hauke Mehrtens <hauke@hauke-m.de>
Signed-off-by: Ioana Ciornei <ioana.ciornei@nxp.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
|
|
In an attempt to actually support shared IRQs in phylib, we now move the
responsibility of triggering the phylib state machine or just returning
IRQ_NONE, based on the IRQ status register, to the PHY driver. Having
3 different IRQ handling callbacks (.handle_interrupt(),
.did_interrupt() and .ack_interrupt() ) is confusing so let the PHY
driver implement directly an IRQ handler like any other device driver.
Make this driver follow the new convention.
Cc: Mathias Kresin <dev@kresin.me>
Cc: Hauke Mehrtens <hauke@hauke-m.de>
Signed-off-by: Ioana Ciornei <ioana.ciornei@nxp.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
|
|
Recently genphy_read_abilities() has been added that dynamically detects
clause 22 PHY abilities. I *think* this detection should work with all
supported PHY's, at least for the ones with basic features sets, i.e.
PHY_BASIC_FEATURES and PHY_GBIT_FEATURES. So let's remove setting these
features explicitly and rely on phylib feature detection.
I don't have access to most of these PHY's, therefore I'd appreciate
regression testing.
v2:
- make the feature constant a comment so that readers know which
features are supported by the respective PHY
Signed-off-by: Heiner Kallweit <hkallweit1@gmail.com>
Tested-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Where the license text and the MODULE_LICENSE() value agree, convert
to using an SPDX header, removing the license text.
Signed-off-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Now that flag PHY_HAS_INTERRUPT has been replaced with a check for
callbacks config_intr and ack_interrupt, we can remove setting this
flag from all driver configs.
Last but not least remove flag PHY_HAS_INTERRUPT completely.
Signed-off-by: Heiner Kallweit <hkallweit1@gmail.com>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
The phys embedded into the v1.1 of the VR9 SoC are using different phy
ids. Add the phy ids to use the driver for this VR9 version as well.
Signed-off-by: Mathias Kresin <dev@kresin.me>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
The VR9 phy ids are matching only for the SoC version 1.2. Rename the
macros and change the names to take this into account.
Signed-off-by: Mathias Kresin <dev@kresin.me>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
from drivers
Remove generic settings for callbacks config_aneg and read_status
from drivers.
Signed-off-by: Heiner Kallweit <hkallweit1@gmail.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Switch everyone over to using phy_read_mmd() and phy_write_mmd() now
that they are able to handle both Clause 22 indirect addressing and
Clause 45 direct addressing methods to the MMD registers.
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: Russell King <rmk+kernel@armlinux.org.uk>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Instead of having individual PHY drivers set the SUPPORTED_Pause and
SUPPORTED_Asym_Pause flags, phylib itself should set those flags,
unless there is a hardware erratum or other special case. During
autonegotiation, the PHYs will determine whether to enable pause
frame support.
Pause frames are a feature that is supported by the MAC. It is the MAC
that generates the frames and that processes them. The PHY can only be
configured to allow them to pass through.
This commit also effectively reverts the recently applied c7a61319
("net: phy: dp83848: Support ethernet pause frames").
So the new process is:
1) Unless the PHY driver overrides it, phylib sets the SUPPORTED_Pause
and SUPPORTED_AsymPause bits in phydev->supported. This indicates that
the PHY supports pause frames.
2) The MAC driver checks phydev->supported before it calls phy_start().
If (SUPPORTED_Pause | SUPPORTED_AsymPause) is set, then the MAC driver
sets those bits in phydev->advertising, if it wants to enable pause
frame support.
3) When the link state changes, the MAC driver checks phydev->pause and
phydev->asym_pause, If the bits are set, then it enables the corresponding
features in the MAC. The algorithm is:
if (phydev->pause)
The MAC should be programmed to receive and honor
pause frames it receives, i.e. enable receive flow control.
if (phydev->pause != phydev->asym_pause)
The MAC should be programmed to transmit pause
frames when needed, i.e. enable transmit flow control.
Signed-off-by: Timur Tabi <timur@codeaurora.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
This adds support for the Intel (former Lantiq) XWAY 11G and 22E PHYs.
These PHYs are also named PEF 7061, PEF 7071, PEF 7072.
Signed-off-by: John Crispin <john@phrozen.org>
Signed-off-by: Hauke Mehrtens <hauke@hauke-m.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
|