Age | Commit message (Collapse) | Author |
|
Some systems have PCI addresses that don't fit in unsigned long (eg some
32-bit PowerPC 440 systems have 36-bit bus addresses). Fix up mlx4 drivers
by using phys_addr_t where appropriate, so we don't truncate any PCI
resource addresses before ioremapping them.
Signed-off-by: Roland Dreier <rolandd@cisco.com>
|
|
Remove near duplication of format string constants by using the newly
introduced vsprintf extention %pV to reduce text by 20k or so.
$ size drivers/net/mlx4/built-in.o*
text data bss dec hex filename
161367 1866 48784 212017 33c31 drivers/net/mlx4/built-in.o
142621 1866 46248 190735 2e90f drivers/net/mlx4/built-in.o.new
Use printk_once as appropriate.
Convert printks to pr_<level>, some bare printks now use pr_cont.
Remove now unused #define PFX.
Signed-off-by: Joe Perches <joe@perches.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
catas_reset() uses pointer to mlx4_priv, but mlx4_priv is not valid
after call mlx4_restart_one().
Signed-off-by: Vitaliy Gusev <vgusev@openvz.org>
Acked-by: Roland Dreier <rolandd@cisco.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
When a port's link is down (except to driver restart) and the port is
configured for auto sensing, we try to sense port link type (Ethernet
or InfiniBand) in order to determine how to initialize the port. If
the port type needs to be changed, all mlx4 for the device interfaces
are unregistered and then registered again with the new port
types. Sensing is done with intervals of 3 seconds.
Signed-off-by: Yevgeny Petrilin <yevgenyp@mellanox.co.il>
Signed-off-by: Roland Dreier <rolandd@cisco.com>
|
|
Update existing Mellanox copyright lines to 2008, and add such lines
to files where they are missing.
Signed-off-by: Jack Morgenstein <jackm@dev.mellanox.co.il>
Signed-off-by: Roland Dreier <rolandd@cisco.com>
|
|
The struct mlx4_interface.event() method was supposed to get an enum
mlx4_dev_event, but the driver code was actually passing in the
hardware enum mlx4_event values. Fix up the callers of
mlx4_dispatch_event() so that they pass in the right type of value,
and fix up the event method in mlx4_ib so that it can handle the enum
mlx4_dev_event values.
This eliminates the need for the subtype parameter to the event
method, so remove it.
This also fixes the sparse warning
drivers/net/mlx4/intf.c:127:48: warning: mixing different enum types
drivers/net/mlx4/intf.c:127:48: int enum mlx4_event versus
drivers/net/mlx4/intf.c:127:48: int enum mlx4_dev_event
Signed-off-by: Roland Dreier <rolandd@cisco.com>
|
|
Reset the device when an internal error is detected.
Also, detect errors by polling the error buffer rather than using
interrupts. This is more robust and doesn't depend on MSI-X. Remove
the old interrupt handler entirely, since we don't want to support two
mechanisms for detecting internal errors.
Signed-off-by: Jack Morgenstein <jackm@dev.mellanox.co.il>
Signed-off-by: Roland Dreier <rolandd@cisco.com>
|
|
Add an InfiniBand driver for Mellanox ConnectX adapters. Because
these adapters can also be used as ethernet NICs and Fibre Channel
HBAs, the driver is split into two modules:
mlx4_core: Handles low-level things like device initialization and
processing firmware commands. Also controls resource allocation
so that the InfiniBand, ethernet and FC functions can share a
device without stepping on each other.
mlx4_ib: Handles InfiniBand-specific things; plugs into the
InfiniBand midlayer.
Signed-off-by: Roland Dreier <rolandd@cisco.com>
|