SCPI specification v1.1 adds support for energy sensors. This patch
adds support for the same.
Acked-by: Guenter Roeck <linux@roeck-us.net>
Reviewed-by: Punit Agrawal <punit.agrawal@arm.com>
Signed-off-by: Sudeep Holla <sudeep.holla@arm.com>
|
|
SCPI specification version 1.1 extended the sensor from 32-bit to 64-bit
values in order to accommodate new sensor class with 64-bit requirements
Since the SCPI driver sets the higher 32-bit for older protocol version
to zeros, there's no need to explicitly check the SCPI protocol version
and the backward compatibility is maintainted.
Acked-by: Guenter Roeck <linux@roeck-us.net>
Reviewed-by: Punit Agrawal <punit.agrawal@arm.com>
Signed-off-by: Sudeep Holla <sudeep.holla@arm.com>
|
|
Currently it's assumed that firmware exports only the class of sensors
supported by the driver. However with newer firmware or SCPI protocol
revision, support for newer classes of sensors can be present.
The driver fails to probe with the following warning if an unsupported
class of sensor is encountered in the firmware.
sysfs: cannot create duplicate filename
'/devices/platform/scpi/scpi:sensors/hwmon/hwmon0/'
------------[ cut here ]------------
WARNING: at fs/sysfs/dir.c:31
Modules linked in:
CPU: 0 PID: 6 Comm: kworker/u12:0 Not tainted 4.3.0-rc7 #137
Hardware name: ARM Juno development board (r0) (DT)
Workqueue: deferwq deferred_probe_work_func
PC is at sysfs_warn_dup+0x54/0x78
LR is at sysfs_warn_dup+0x54/0x78
This patch fixes the above issue by skipping through the unsupported
class of SCPI sensors.
Fixes: 68acc77a2d51 ("hwmon: Support thermal zones registration for SCP temperature sensors")
Fixes: ea98b29a05e9 ("hwmon: Support sensors exported via ARM SCP interface")
Cc: Guenter Roeck <linux@roeck-us.net>
Reviewed-by: Punit Agrawal <punit.agrawal@arm.com>
Signed-off-by: Sudeep Holla <sudeep.holla@arm.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
|
|
Add support to create thermal zones based on the temperature sensors
provided by the SCP. The thermal zones can be defined using the
thermal DT bindings and should refer to the SCP sensor id to select
the sensor.
Signed-off-by: Punit Agrawal <punit.agrawal@arm.com>
Acked-by: Guenter Roeck <linux@roeck-us.net>
Cc: Eduardo Valentin <edubezval@gmail.com>
|
|
Create a driver to add support for SoC sensors exported by the System
Control Processor (SCP) via the System Control and Power Interface
(SCPI). The supported sensor types is one of voltage, temperature,
current, and power.
The sensor labels and values provided by the SCP are exported via the
hwmon sysfs interface.
Signed-off-by: Punit Agrawal <punit.agrawal@arm.com>
Acked-by: Guenter Roeck <linux@roeck-us.net>
Cc: Sudeep Holla <sudeep.holla@arm.com>
|