Age | Commit message (Collapse) | Author |
|
The scpi hwmon shows the sub-zero temperature in an unsigned integer,
which would confuse the users when the machine works in low temperature
environment. This shows the sub-zero temperature in an signed value and
users can get it properly from sensors.
Signed-off-by: Riwen Lu <luriwen@kylinos.cn>
Tested-by: Xin Chen <chenxin@kylinos.cn>
Link: https://lore.kernel.org/r/20210604030959.736379-1-luriwen@kylinos.cn
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
|
|
This gets rid of the unnecessary license boilerplate, and avoids
having to deal with individual patches one by one.
No functional changes intended.
Reviewed-by: Corentin Labbe <clabbe.montjoie@gmail.com>
Reviewed-by: Jean Delvare <jdelvare@suse.de>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
|
|
Replace S_<PERMS> with octal values.
The conversion was done automatically with coccinelle. The semantic patches
and the scripts used to generate this commit log are available at
https://github.com/groeck/coccinelle-patches/hwmon/.
This patch does not introduce functional changes. It was verified by
compiling the old and new files and comparing text and data sizes.
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
|
|
The continue will not truely skip any code. hence it is safe to
remove it.
Signed-off-by: zhong jiang <zhongjiang@huawei.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
|
|
The thermal_zone_of_device_ops structure is only passed as the fourth
argument to devm_thermal_zone_of_sensor_register, which is declared
as const. Thus the thermal_zone_of_device_ops structure itself can
be const.
Done with the help of Coccinelle.
Signed-off-by: Julia Lawall <Julia.Lawall@lip6.fr>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
|
|
The implementation details for SCPI seems to suggest that the sensor
readings must be reported by SCP using a well defined scale
(millidegree Celsius for temperature, millivolts for voltage,
milliamperes for current, microwatts for power and microjoules for
energy).
This is also important for the interaction with other subsystems: for
example both the thermal sub-system and the hwmon sysfs interface expect
the temperature expressed in millidegree Celsius.
Unfortunately since this behaviour is dependent on the firmware
implementation there are cases where the sensor readings are reported
using a different scale. For example in the Amlogic SoCs the
temperature is reported in degree and not millidegree Celsius.
To take into account this discrepancy and fixup the values reported by
SCP a new compatible 'amlogic,meson-gxbb-scpi-sensors' is introduced and
used in this patch by the scpi-hwmon driver to convert the sensor
readings to the expected scale.
Signed-off-by: Carlo Caione <carlo@endlessm.com>
Acked-by: Sudeep Holla <sudeep.holla@arm.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
|
|
If the driver is built as a module, autoload won't work because the module
alias information is not filled. So user-space can't match the registered
device with the corresponding module.
Export the module alias information using the MODULE_DEVICE_TABLE() macro.
Before this patch:
$ modinfo drivers/hwmon/scpi-hwmon.ko | grep alias
$
After this patch:
$ modinfo drivers/hwmon/scpi-hwmon.ko | grep alias
alias: of:N*T*Carm,scpi-sensorsC*
alias: of:N*T*Carm,scpi-sensors
Signed-off-by: Javier Martinez Canillas <javier@osg.samsung.com>
Fixes: ea98b29a05e9c ("hwmon: Support sensors exported via ARM SCP interface")
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
|
|
The field "owner" is set by the core.
Thus delete an unneeded initialisation.
Generated by: scripts/coccinelle/api/platform_no_drv_owner.cocci
Signed-off-by: Markus Elfring <elfring@users.sourceforge.net>
Acked-by: Sudeep Holla <sudeep.holla@arm.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
|
|
This changes the driver to use the devm_ version
of thermal_zone_of_sensor_register and cleans
up the local points and unregister calls.
Cc: Jean Delvare <jdelvare@suse.com>
Cc: Guenter Roeck <linux@roeck-us.net>
Cc: lm-sensors@lm-sensors.org
Cc: linux-kernel@vger.kernel.org
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
|
|
SCPI specification v1.1 adds support for energy sensors. This patch
adds support for the same.
Acked-by: Guenter Roeck <linux@roeck-us.net>
Reviewed-by: Punit Agrawal <punit.agrawal@arm.com>
Signed-off-by: Sudeep Holla <sudeep.holla@arm.com>
|
|
SCPI specification version 1.1 extended the sensor from 32-bit to 64-bit
values in order to accommodate new sensor class with 64-bit requirements
Since the SCPI driver sets the higher 32-bit for older protocol version
to zeros, there's no need to explicitly check the SCPI protocol version
and the backward compatibility is maintainted.
Acked-by: Guenter Roeck <linux@roeck-us.net>
Reviewed-by: Punit Agrawal <punit.agrawal@arm.com>
Signed-off-by: Sudeep Holla <sudeep.holla@arm.com>
|
|
Currently it's assumed that firmware exports only the class of sensors
supported by the driver. However with newer firmware or SCPI protocol
revision, support for newer classes of sensors can be present.
The driver fails to probe with the following warning if an unsupported
class of sensor is encountered in the firmware.
sysfs: cannot create duplicate filename
'/devices/platform/scpi/scpi:sensors/hwmon/hwmon0/'
------------[ cut here ]------------
WARNING: at fs/sysfs/dir.c:31
Modules linked in:
CPU: 0 PID: 6 Comm: kworker/u12:0 Not tainted 4.3.0-rc7 #137
Hardware name: ARM Juno development board (r0) (DT)
Workqueue: deferwq deferred_probe_work_func
PC is at sysfs_warn_dup+0x54/0x78
LR is at sysfs_warn_dup+0x54/0x78
This patch fixes the above issue by skipping through the unsupported
class of SCPI sensors.
Fixes: 68acc77a2d51 ("hwmon: Support thermal zones registration for SCP temperature sensors")
Fixes: ea98b29a05e9 ("hwmon: Support sensors exported via ARM SCP interface")
Cc: Guenter Roeck <linux@roeck-us.net>
Reviewed-by: Punit Agrawal <punit.agrawal@arm.com>
Signed-off-by: Sudeep Holla <sudeep.holla@arm.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
|
|
Add support to create thermal zones based on the temperature sensors
provided by the SCP. The thermal zones can be defined using the
thermal DT bindings and should refer to the SCP sensor id to select
the sensor.
Signed-off-by: Punit Agrawal <punit.agrawal@arm.com>
Acked-by: Guenter Roeck <linux@roeck-us.net>
Cc: Eduardo Valentin <edubezval@gmail.com>
|
|
Create a driver to add support for SoC sensors exported by the System
Control Processor (SCP) via the System Control and Power Interface
(SCPI). The supported sensor types is one of voltage, temperature,
current, and power.
The sensor labels and values provided by the SCP are exported via the
hwmon sysfs interface.
Signed-off-by: Punit Agrawal <punit.agrawal@arm.com>
Acked-by: Guenter Roeck <linux@roeck-us.net>
Cc: Sudeep Holla <sudeep.holla@arm.com>
|