2011-10-24hwmon: (pmbus_core) Simplify sign extensionsGuenter Roeck
Shift operations can be used for sign extensions. Use it. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-10-24hwmon: (pmbus) Add support for TEMP2 peak attributesGuenter Roeck
At least one PMBus chip supports peak attributes for READ_TEMPERATURE2. Add virtual registers to be able to report it to the user. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-10-24hwmon: (pmbus) Always call _pmbus_read_byte in core driverGuenter Roeck
Always call _pmbus_read_byte() instead of pmbus_read_byte() in PMBus core driver. With this change, device specific read functions can be implemented for all registers. Since the device specific read_byte function is now always called, we need to be more careful with page validations. Only fail if the passed page number is larger than 0, since -1 means "current page". Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-10-24hwmon: (pmbus) Replace EINVAL return codes with more appropriate errorsGuenter Roeck
EINVAL was over-used in the code. Replace it with more appropriate errors. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-10-24hwmon: (pmbus) Don't return errors from driver remove functionsGuenter Roeck
Driver remove functions have an error return value, but rarely return an error in practice. If a driver does return an error from its remove function, the driver won't be unloaded and is expected to stay alive. pmbus_do_remove() is defined as returning an int, but always returns 0 (no error). Calling code passes that return value on to high level driver remove functions, but does not evaluate it and removes driver data even if pmbus_do_remove() returned an error (which it in practice never does). Even if this code could never cause a real problem, it is nevertheless conceptually wrong. To reduce confusion and simplify the code, change pmbus_do_remove() to be a void function, and have PMBus client drivers always return zero in their driver remove functions. Reported-by: Jean Delvare <khali@linux-fr.org> Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Acked-by: Jean Delvare <khali@linux-fr.org>
2011-09-13hwmon: (pmbus) Fix low limit temperature alarmsGuenter Roeck
Temperature alarms are detected by checking the alarm bit and comparing temperature limits against the current temperature. For low limits, this comparison needs to be reversed (temp < limit instead of temp > limit). This was not taken into account, resulting in wrong alarms if a temperature fell below a low limit. Fix by adding a low limit flag in the limit data structure. When creating the sensor entry, the order of registers to compare is now reversed for low limits. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Acked-by: Jean Delvare <khali@linux-fr.org> Cc: stable@kernel.org # 3.0+
2011-08-11hwmon: (pmbus) Virtualize pmbus_write_byteGuenter Roeck
With virtual pages and to be able to handle more chips, it is necessary to virtualise pmbus_write_byte(). Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28hwmon: (pmbus) Add client driver for LM25066, LM5064, and LM5066Guenter Roeck
PMBus client driver supporting National Semiconductor LM25066, LM5064, and LM5066. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28hwmon: (pmbus) Add support for peak attributesGuenter Roeck
Most PMBus devices provide manufacturer specific commands to read low and/or high peak values for some or all of its sensors. To support providing those values as lowest/highest attributes to the user, introduce virtual PMBus commands. Those commands reside outside the normal command set and have to be implemented in device specific code, which map the virtual commands to device specific commands. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28hwmon: (pmbus) Strengthen check for status register existenceGuenter Roeck
With virtual register page support, it is now possible that the status register on virtual pages does not exist or is itself virtual. To take this into account when creating alarm attributes, generate those attributes only if the status register on the respective page is known to exist. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28hwmon: (pmbus) Add support for virtual pagesGuenter Roeck
Some PMBus chips have non-standard sensor registers. An easy way to support such sensors is to introduce virtual pages and map the non-standard registers into standard registers on an extra page. For this to work, the code verifying if the configured number of pages exists has to be removed. Since a wrong number of pages can only be configured in a front-end driver, this should not have a practical impact since the resulting errors should be found during development and testing. Also, functions to read the chip status while checking if a command register exists must be modified to no longer set the page register before reading the status, since the physical page associated with the checked register may not exist. This does not make a functional difference since the page was already set when the attempt to read the register was made. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28hwmon: (pmbus) Support reading and writing of word registers in device ↵Guenter Roeck
specific code Some PMBus devices use non-standard registers for some of the sensors and/or limits. To support such devices, add code to support reading and writing of word size registers in device specific code. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28hwmon: (pmbus) Increase attribute name sizeGuenter Roeck
Some hwmon sysfs attributes have a length of 20 bytes (plus terminating 0). I2C_NAME_SIZE is defined as 20 and thus can not be used to define the length of hwmon sysfs attributes. Replace it with PMBUS_NAME_SIZE, set to 24. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28hwmon: (pmbus) Add support for VID output voltage modeGuenter Roeck
In VID mode, output voltages are measured and reported as VID values, and have to be converted to voltages using VID conversion tables or functions. Support is added for VR11 only at this time. This patch enables support for PMBus devices supporting VID VR11 based output voltage selection such as NCP4200 and NCP4208. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28hwmon: (pmbus) Move PMBus drivers to drivers/hwmon/pmbusGuenter Roeck
Since the number of PMBus drivers is getting large, move them into directory drivers/hwmon/pmbus to improve readability and scalability. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>