summaryrefslogtreecommitdiff
path: root/arch/s390/kernel/pgm_check.S
AgeCommit message (Collapse)Author
2014-10-09s390: add support for vector extensionMartin Schwidefsky
The vector extension introduces 32 128-bit vector registers and a set of instruction to operate on the vector registers. The kernel can control the use of vector registers for the problem state program with a bit in control register 0. Once enabled for a process the kernel needs to retain the content of the vector registers on context switch. The signal frame is extended to include the vector registers. Two new register sets NT_S390_VXRS_LOW and NT_S390_VXRS_HIGH are added to the regset interface for the debugger and core dumps. Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
2013-11-25s390/mm: handle asce-type exceptions as normal page faultMartin Schwidefsky
Git commit 9e34f2686bb088b211b6cac8772e1f644c6180f8 "s390/mm,tlb: tlb flush on page table upgrade fixup" removed the exception handler for the asce-type exception. This is incorrect as the user-copy with MVCOS can cause asce-type exceptions in the kernel if a user pointer is too large. Those need to be handled with do_no_context to branch to the fixup in the user-copy code. The simplest fix for this problem is to call do_dat_exception for asce-type excpetions, as there is no vma for the address the code will handle the exception correctly. Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
2013-11-04s390/mm,tlb: correct tlb flush on page table upgradeMartin Schwidefsky
The IDTE instruction used to flush TLB entries for a specific address space uses the address-space-control element (ASCE) to identify affected TLB entries. The upgrade of a page table adds a new top level page table which changes the ASCE. The TLB entries associated with the old ASCE need to be flushed and the ASCE for the address space needs to be replaced synchronously on all CPUs which currently use it. The concept of a lazy ASCE update with an exception handler is broken. Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
2012-11-23s390/traps: preinitialize program check tableHeiko Carstens
Preinitialize the program check table, so we can put it into the read-only data section. Also use only four byte entries for the table, since each program check handler resides within the first 2GB. Therefore this reduces the size of the table by 50% on 64 bit builds. Signed-off-by: Heiko Carstens <heiko.carstens@de.ibm.com> Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>