Age | Commit message (Collapse) | Author |
|
Use macro to replace the magic number.
Signed-off-by: Zong Li <zong@andestech.com>
Acked-by: Greentime Hu <greentime@andestech.com>
Signed-off-by: Greentime Hu <greentime@andestech.com>
|
|
Function graph tracer has modified the return address to
'return_to_handler' on stack, and provide the 'ftrace_graph_ret_addr' to
get the real return address.
Signed-off-by: Zong Li <zong@andestech.com>
Acked-by: Greentime Hu <greentime@andestech.com>
Signed-off-by: Greentime Hu <greentime@andestech.com>
|
|
It broke the 'allmodconfig' build.
LD vmlinux
SYSMAP System.map
Building modules, stage 2.
MODPOST 5028 modules
ERROR: "flush_dcache_page" [net/sunrpc/xprtrdma/rpcrdma.ko] undefined!
ERROR: "empty_zero_page" [net/ceph/libceph.ko] undefined!
ERROR: "save_stack_trace" [kernel/backtracetest.ko] undefined!
ERROR: "clear_page" [fs/ocfs2/dlm/ocfs2_dlm.ko] undefined!
ERROR: "copy_page" [fs/nilfs2/nilfs2.ko] undefined!
...
Signed-off-by: Greentime Hu <greentime@andestech.com>
Acked-by: Arnd Bergmann <arnd@arndb.de>
|
|
This patch includes the exception/interrupt entries, pt_reg structure and
related accessors.
/* Unaligned accessing handling*/
Andes processors cannot load/store information which is not naturally
aligned on the bus, i.e., loading a 4 byte data whose start address must
be divisible by 4. If unaligned data accessing is happened, data
unaligned exception will be triggered and user will get SIGSEGV or
kernel oops according to the unaligned address. In order to make user be
able to load/store data from an unaligned address, software load/store
emulation is implemented in arch/nds32/mm/alignment.c to address data
unaligned exception.
Unaligned accessing handling is disabled by default because it is not a
normal case. User can enable this feature by following steps.
A. Compile time:
1. Enable kernel config CONFIG_ALIGNMENT_TRAP
B. Run time:
1. Enter /proc/sys/nds32/unaligned_acess folder
2. Write 1 to file enable_mode to enable unaligned accessing
handling. User can disable it by writing 0 to this file.
3. Write 1 to file debug to show which unaligned address is under
processing. User can disable it by writing 0 to this file.
However, unaligned accessing handler cannot work if this unaligned
address is not accessible such as protection violation. On this
condition, the default behaviors for addressing data unaligned exception
still happen
Signed-off-by: Vincent Chen <vincentc@andestech.com>
Signed-off-by: Greentime Hu <greentime@andestech.com>
Acked-by: Arnd Bergmann <arnd@arndb.de>
|