Age | Commit message (Collapse) | Author |
|
dev_err() needs a terminating newline.
Signed-off-by: Luca Ceresoli <luca@lucaceresoli.net>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
The commit is a nice cleanup, but breaks booting on exynos5 based
chromebooks. It's seems to come down to exynos5's i2c driver not
implementing I2C_FUNC_SMBUS_READ_BLOCK_DATA. It's not yet clear
why that breaks boot / massively slows it down when userspace
starts, so revert the problematic patch.
This reverts commit c4b12a2f3f3de670f6be5e96092a2cab0b877f1a.
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
This depends on the simplification of sbs_read_string_data, which
breaks booting exynos5 based chromebooks. More investigation is
required, so this patch and the simplification patch are reverted
for this merge window.
Note, that this is only a partial revert, since sbs_update_presence()
has not been removed. It is also required for the charger broadcast
disabling.
This reverts commit 79bcd5a4a66076a8a8dacd7f4a3be1952283aef4.
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
Convert sbs-battery bindings to YAML.
Reviewed-by: Rob Herring <robh@kernel.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
sbs-battery does not use the ID parameter, so switch to i2c's
probe_new API.
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
Switch from DT specific of_property_* API to generic and more
modern device_property_* API.
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
In certain designs, it is possible to add a battery on a populated i2c
bus without an sbs compliant charger. In that case, the battery will
unnecessarily and sometimes undesirably master the bus trying to write
info in the charger.
It is observed in many occasion that these battery "broadcasts" are even
corrupting other ongoing master to slave communication. I.e. the
multi-master support in the battery is inadequate.
Thankfully, the CHARGER_MODE bit allows designers to disable that SBS
battery behaviour.
This needs to be done once when the battery is first seen on the bus.
Signed-off-by: Jean-Francois Dagenais <jeff.dagenais@gmail.com>
[rebased code]
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
A battery, that is neither charged, nor discharged is not
always Full. If the charger is disabled for other reasons
it might simply be idle and should be marked accordingly.
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
Add support for reporting the SBS battery's condition flag
to userspace using the new "Calibration required" health status.
Reviewed-by: Emil Velikov <emil.velikov@collabora.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
Expose the battery's manufacture date to userspace.
Reviewed-by: Emil Velikov <emil.velikov@collabora.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT/VOLTAGE_MAX support
Expose maximum charge current/voltage information requested
by the battery.
Reviewed-by: Emil Velikov <emil.velikov@collabora.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
This reads the battery chemistry from the battery chip instead
of incorrectly hardcoding the type to be Li-Ion.
Reviewed-by: Emil Velikov <emil.velikov@collabora.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
Expose averaged current information, which is part of the SBS
standard and should be supported by all batteries.
Reviewed-by: Emil Velikov <emil.velikov@collabora.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
SBS batteries optionally have support for PEC. This enables
PEC handling based on the implemented SBS version as suggested
by the standard. The support for PEC is re-evaluated when the
battery is hotplugged into the system, since there might be
systems supporting batteries from different SBS generations.
Reviewed-by: Emil Velikov <emil.velikov@collabora.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
The SBS battery implements SMBus block reads. Currently the
driver "emulates" this by doing an I2C byte read for the
length followed by an I2C block read. The I2C subsystem
actually provides a proper API for doing SMBus block reads,
which can and should be used instead. The current implementation
does not properly handle packet error checking (PEC).
This change requires, that I2C bus drivers support I2C_M_RECV_LEN
or directly provide the SMBus API to access device manufacturer
and model name.
Reviewed-by: Emil Velikov <emil.velikov@collabora.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
Add support for reporting the MaxError register from
battery fuel gauges following the smart battery standard.
Reviewed-by: Emil Velikov <emil.velikov@collabora.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
Add support for BQ20Z65 manufacturer data to the sbs-battery
driver. Implementation has been verified using the public TRM
available from [0] and tested using a GE Flex 3S2P battery.
[0] http://www.ti.com/lit/pdf/sluu386
Acked-by: Rob Herring <robh@kernel.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
Some battery fuel gauges know when the battery needs to
be recalibrated before providing usable values. This
should be reported via the health property.
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
Some smart batteries store their manufacture date, which is
useful to identify the battery and/or to know about the cell
quality.
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
Add a property for reporting the error margin expected
by fuel gauge chips.
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
SBS battery driver exposes 32 power supply properties now,
which will result in uevent failure on (un)plugging the
battery. Other drivers (e.g. bq27xxx) are also coming close
to this limit, so increase it.
Acked-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Reviewed-by: Emil Velikov <emil.velikov@collabora.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
Fix the following sparse warning:
drivers/power/supply/bd99954-charger.c:1028:6: warning: symbol 'bd9995x_chip_reset' was not declared.
The bd9995x_chip_reset() has only one call site within bd99954-charger.c
It should be static
Fixes: 0902f8366491 ("power: supply: Support ROHM bd99954 charger")
Reported-by: Hulk Robot <hulkci@huawei.com>
Signed-off-by: Samuel Zou <zou_wei@huawei.com>
Reviewed-by: Matti Vaittinen <matti.vaittinen@fi.rohmeurope.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
Add device tree compatible strings and create proper modalias structures
to let this driver load automatically if compiled as module, because
max14577 MFD driver creates MFD cells with such compatible strings.
Signed-off-by: Marek Szyprowski <m.szyprowski@samsung.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
This merges the MP2629 battery charge management immutable branch
between MFD, IIO and power-supply due for the v5.8 merge window
into power-supply for-next branch.
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
Since normally syscon-reboot block is supposed to be a part of a system
controller, lets look for the syscon regmap in a parental DT node if
regmap property isn't specified. DT binding from now considers the regmap
property as deprecated.
Signed-off-by: Serge Semin <Sergey.Semin@baikalelectronics.ru>
Cc: Alexey Malahov <Alexey.Malahov@baikalelectronics.ru>
Cc: Thomas Bogendoerfer <tsbogend@alpha.franken.de>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
Since normally syscon-reboot block is supposed to be a part of a system
controller, lets mark the regmap property as deprecated and recommend the
syscon-reboot node to be a sub-node of SYSCON.
Signed-off-by: Serge Semin <Sergey.Semin@baikalelectronics.ru>
Reviewed-by: Rob Herring <robh@kernel.org>
Cc: Alexey Malahov <Alexey.Malahov@baikalelectronics.ru>
Cc: Thomas Bogendoerfer <tsbogend@alpha.franken.de>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
Add MAINTAINERS entry for Monolithic Power Systems mp2629 Charger driver.
Signed-off-by: Saravanan Sekar <sravanhome@gmail.com>
Reviewed-by: Andy Shevchenko <andy.shevchenko@gmail.com>
Reviewed-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
|
|
Allows the user to compensate the intrinsic resistance of the battery
to accelerate the charging cycle.
Signed-off-by: Saravanan Sekar <sravanhome@gmail.com>
Reviewed-by: Andy Shevchenko <andy.shevchenko@gmail.com>
Reviewed-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
|
|
The mp2629 provides switching-mode battery charge management for
single-cell Li-ion or Li-polymer battery. Driver supports the
access/control input source and battery charging parameters.
Signed-off-by: Saravanan Sekar <sravanhome@gmail.com>
Reviewed-by: Andy Shevchenko <andy.shevchenko@gmail.com>
Reviewed-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
|
|
Add support for 8-bit resolution ADC readings for input power
supply and battery charging measurement. Provides voltage, current
readings to mp2629 power supply driver.
Signed-off-by: Saravanan Sekar <sravanhome@gmail.com>
Reviewed-by: Andy Shevchenko <andy.shevchenko@gmail.com>
Reviewed-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
|
|
mp2629 is a highly-integrated switching-mode battery charge management
device for single-cell Li-ion or Li-polymer battery.
Add MFD core enables chip access for ADC driver for battery readings,
and a power supply battery-charger driver
Signed-off-by: Saravanan Sekar <sravanhome@gmail.com>
Reviewed-by: Andy Shevchenko <andy.shevchenko@gmail.com>
Reviewed-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
|
|
Add device tree binding information for mp2629 mfd driver.
Signed-off-by: Saravanan Sekar <sravanhome@gmail.com>
Reviewed-by: Andy Shevchenko <andy.shevchenko@gmail.com>
Reviewed-by: Rob Herring <robh@kernel.org>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
|
|
Convert the bq27xxx.txt to yaml format
CC: Pali Rohár <pali@kernel.org>
CC: Andrew F. Davis <afd@ti.com>
Signed-off-by: Dan Murphy <dmurphy@ti.com>
Reviewed-by: Rob Herring <robh@kernel.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
Move away from the deprecated API in this comment.
Signed-off-by: Wolfram Sang <wsa+renesas@sang-engineering.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
Report REG00.IINLIM value as INPUT_CURRENT_LIMIT property.
Signed-off-by: Michał Mirosław <mirq-linux@rere.qmqm.pl>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
Report configured precharge current.
Signed-off-by: Michał Mirosław <mirq-linux@rere.qmqm.pl>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
Report charging type based on recently read state.
Signed-off-by: Michał Mirosław <mirq-linux@rere.qmqm.pl>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
Edge interrupts from the charger may be lost or stuck in fault mode
since probe(). Check if something changed everytime userspace wants
some data.
Signed-off-by: Michał Mirosław <mirq-linux@rere.qmqm.pl>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
Datasheet describes two modes for reading ADC measurements:
1. continuous, 1 Hz - enabled and started by CONV_RATE bit
2. one-shot - triggered by CONV_START bit
In continuous mode, CONV_START is read-only and signifies an ongoing
conversion.
Change the code to follow the datasheet and really disable continuous
mode for power saving.
Signed-off-by: Michał Mirosław <mirq-linux@rere.qmqm.pl>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
Charge Current is more apropriately reflected by CURRENT_NOW property
(measured current) than CONSTANT_CURRENT_VOLTAGE (configured CC-phase
current limit). Fix the reference and make the sign reflect direction
of the current.
Signed-off-by: Michał Mirosław <mirq-linux@rere.qmqm.pl>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
According to the datasheet available at (1), the bottom four
bits are always zero and the actual voltage is 1.25x this value
in mV. Since the kernel API specifies that voltages should be in
uV, it should report 1250x the shifted value.
1) https://datasheets.maximintegrated.com/en/ds/MAX17040-MAX17041.pdf
Signed-off-by: Jonathan Bakker <xc-racer2@live.ca>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
The framework is unhappy about them, because it uses the names in sysfs
attributes:
power_supply olpc-ac: hwmon: 'olpc-ac' is not a valid name attribute, please fix
power_supply olpc-battery: hwmon: 'olpc-battery' is not a valid name attribute, please fix
See also commit 648cd48c9e56 ("hwmon: Do not accept invalid name
attributes") and commit 74d3b6419772 ("hwmon: Relax name attribute
validation for new APIs").
Signed-off-by: Lubomir Rintel <lkundrak@v3.sk>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
This delay-fix is picked up from downstream driver,
we measured that 25 - 35 ms delay ensure that we get required data.
Tested on SMB347 on Nexus 7 2012. Otherwise IRQSTAT_E fails to provide
correct information.
Signed-off-by: Dmitry Osipenko <digetx@gmail.com>
Signed-off-by: David Heidelberg <david@ixit.cz>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
Fix failure when USB cable is connected:
smb347 2-006a: reading IRQSTAT_D failed
Fixes: 1502cfe19bac ("smb347-charger: Fix battery status reporting logic for charger faults")
Tested-by: David Heidelberg <david@ixit.cz>
Signed-off-by: Dmitry Osipenko <digetx@gmail.com>
Signed-off-by: David Heidelberg <david@ixit.cz>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
The "default n" is not needed as it is, well, default. Clean
the KConfig by removing "default n".
Signed-off-by: Matti Vaittinen <matti.vaittinen@fi.rohmeurope.com>
Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
Indent the help text as explained in
Documentation/process/coding-style.rst
Signed-off-by: Matti Vaittinen <matti.vaittinen@fi.rohmeurope.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
The ROHM BD99954 is a Battery Management LSI for 1-4 cell Lithium-Ion
secondary battery intended to be used in space-constraint equipment such
as Low profile Notebook PC, Tablets and other applications. BD99954
provides a Dual-source Battery Charger, two port BC1.2 detection and a
Battery Monitor.
Support ROHM BD99954 Charger IC.
Signed-off-by: Matti Vaittinen <matti.vaittinen@fi.rohmeurope.com>
Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
The ROHM BD99954 is a Battery Management LSI for 1-4 cell Lithium-Ion
secondary battery. Intended to be used in space-constraint equipment such
as Low profile Notebook PC, Tablets and other applications. BD99954
provides a Dual-source Battery Charger, two port BC1.2 detection and a
Battery Monitor.
Document the DT bindings for BD99954
Signed-off-by: Matti Vaittinen <matti.vaittinen@fi.rohmeurope.com>
Reviewed-by: Rob Herring <robh@kernel.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
Add parsing of new device-tree battery bindings.
- trickle-charge-current-microamp
- precharge-upper-limit-microvolt
- re-charge-voltage-microvolt
- over-voltage-threshold-microvolt
Signed-off-by: Matti Vaittinen <matti.vaittinen@fi.rohmeurope.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|