diff options
Diffstat (limited to 'drivers/power/charger-manager.c')
-rw-r--r-- | drivers/power/charger-manager.c | 164 |
1 files changed, 111 insertions, 53 deletions
diff --git a/drivers/power/charger-manager.c b/drivers/power/charger-manager.c index 7098a1ce2d3c..ef8094a61f1e 100644 --- a/drivers/power/charger-manager.c +++ b/drivers/power/charger-manager.c @@ -97,6 +97,7 @@ static struct charger_global_desc *g_desc; /* init with setup_charger_manager */ static bool is_batt_present(struct charger_manager *cm) { union power_supply_propval val; + struct power_supply *psy; bool present = false; int i, ret; @@ -107,16 +108,27 @@ static bool is_batt_present(struct charger_manager *cm) case CM_NO_BATTERY: break; case CM_FUEL_GAUGE: - ret = cm->fuel_gauge->get_property(cm->fuel_gauge, + psy = power_supply_get_by_name(cm->desc->psy_fuel_gauge); + if (!psy) + break; + + ret = psy->get_property(psy, POWER_SUPPLY_PROP_PRESENT, &val); if (ret == 0 && val.intval) present = true; break; case CM_CHARGER_STAT: - for (i = 0; cm->charger_stat[i]; i++) { - ret = cm->charger_stat[i]->get_property( - cm->charger_stat[i], - POWER_SUPPLY_PROP_PRESENT, &val); + for (i = 0; cm->desc->psy_charger_stat[i]; i++) { + psy = power_supply_get_by_name( + cm->desc->psy_charger_stat[i]); + if (!psy) { + dev_err(cm->dev, "Cannot find power supply \"%s\"\n", + cm->desc->psy_charger_stat[i]); + continue; + } + + ret = psy->get_property(psy, POWER_SUPPLY_PROP_PRESENT, + &val); if (ret == 0 && val.intval) { present = true; break; @@ -139,14 +151,20 @@ static bool is_batt_present(struct charger_manager *cm) static bool is_ext_pwr_online(struct charger_manager *cm) { union power_supply_propval val; + struct power_supply *psy; bool online = false; int i, ret; /* If at least one of them has one, it's yes. */ - for (i = 0; cm->charger_stat[i]; i++) { - ret = cm->charger_stat[i]->get_property( - cm->charger_stat[i], - POWER_SUPPLY_PROP_ONLINE, &val); + for (i = 0; cm->desc->psy_charger_stat[i]; i++) { + psy = power_supply_get_by_name(cm->desc->psy_charger_stat[i]); + if (!psy) { + dev_err(cm->dev, "Cannot find power supply \"%s\"\n", + cm->desc->psy_charger_stat[i]); + continue; + } + + ret = psy->get_property(psy, POWER_SUPPLY_PROP_ONLINE, &val); if (ret == 0 && val.intval) { online = true; break; @@ -167,12 +185,14 @@ static bool is_ext_pwr_online(struct charger_manager *cm) static int get_batt_uV(struct charger_manager *cm, int *uV) { union power_supply_propval val; + struct power_supply *fuel_gauge; int ret; - if (!cm->fuel_gauge) + fuel_gauge = power_supply_get_by_name(cm->desc->psy_fuel_gauge); + if (!fuel_gauge) return -ENODEV; - ret = cm->fuel_gauge->get_property(cm->fuel_gauge, + ret = fuel_gauge->get_property(fuel_gauge, POWER_SUPPLY_PROP_VOLTAGE_NOW, &val); if (ret) return ret; @@ -189,6 +209,7 @@ static bool is_charging(struct charger_manager *cm) { int i, ret; bool charging = false; + struct power_supply *psy; union power_supply_propval val; /* If there is no battery, it cannot be charged */ @@ -196,17 +217,22 @@ static bool is_charging(struct charger_manager *cm) return false; /* If at least one of the charger is charging, return yes */ - for (i = 0; cm->charger_stat[i]; i++) { + for (i = 0; cm->desc->psy_charger_stat[i]; i++) { /* 1. The charger sholuld not be DISABLED */ if (cm->emergency_stop) continue; if (!cm->charger_enabled) continue; + psy = power_supply_get_by_name(cm->desc->psy_charger_stat[i]); + if (!psy) { + dev_err(cm->dev, "Cannot find power supply \"%s\"\n", + cm->desc->psy_charger_stat[i]); + continue; + } + /* 2. The charger should be online (ext-power) */ - ret = cm->charger_stat[i]->get_property( - cm->charger_stat[i], - POWER_SUPPLY_PROP_ONLINE, &val); + ret = psy->get_property(psy, POWER_SUPPLY_PROP_ONLINE, &val); if (ret) { dev_warn(cm->dev, "Cannot read ONLINE value from %s\n", cm->desc->psy_charger_stat[i]); @@ -219,9 +245,7 @@ static bool is_charging(struct charger_manager *cm) * 3. The charger should not be FULL, DISCHARGING, * or NOT_CHARGING. */ - ret = cm->charger_stat[i]->get_property( - cm->charger_stat[i], - POWER_SUPPLY_PROP_STATUS, &val); + ret = psy->get_property(psy, POWER_SUPPLY_PROP_STATUS, &val); if (ret) { dev_warn(cm->dev, "Cannot read STATUS value from %s\n", cm->desc->psy_charger_stat[i]); @@ -248,6 +272,7 @@ static bool is_full_charged(struct charger_manager *cm) { struct charger_desc *desc = cm->desc; union power_supply_propval val; + struct power_supply *fuel_gauge; int ret = 0; int uV; @@ -255,11 +280,15 @@ static bool is_full_charged(struct charger_manager *cm) if (!is_batt_present(cm)) return false; - if (cm->fuel_gauge && desc->fullbatt_full_capacity > 0) { + fuel_gauge = power_supply_get_by_name(cm->desc->psy_fuel_gauge); + if (!fuel_gauge) + return false; + + if (desc->fullbatt_full_capacity > 0) { val.intval = 0; /* Not full if capacity of fuel gauge isn't full */ - ret = cm->fuel_gauge->get_property(cm->fuel_gauge, + ret = fuel_gauge->get_property(fuel_gauge, POWER_SUPPLY_PROP_CHARGE_FULL, &val); if (!ret && val.intval > desc->fullbatt_full_capacity) return true; @@ -273,10 +302,10 @@ static bool is_full_charged(struct charger_manager *cm) } /* Full, if the capacity is more than fullbatt_soc */ - if (cm->fuel_gauge && desc->fullbatt_soc > 0) { + if (desc->fullbatt_soc > 0) { val.intval = 0; - ret = cm->fuel_gauge->get_property(cm->fuel_gauge, + ret = fuel_gauge->get_property(fuel_gauge, POWER_SUPPLY_PROP_CAPACITY, &val); if (!ret && val.intval >= desc->fullbatt_soc) return true; @@ -551,6 +580,20 @@ static int check_charging_duration(struct charger_manager *cm) return ret; } +static int cm_get_battery_temperature_by_psy(struct charger_manager *cm, + int *temp) +{ + struct power_supply *fuel_gauge; + + fuel_gauge = power_supply_get_by_name(cm->desc->psy_fuel_gauge); + if (!fuel_gauge) + return -ENODEV; + + return fuel_gauge->get_property(fuel_gauge, + POWER_SUPPLY_PROP_TEMP, + (union power_supply_propval *)temp); +} + static int cm_get_battery_temperature(struct charger_manager *cm, int *temp) { @@ -560,15 +603,18 @@ static int cm_get_battery_temperature(struct charger_manager *cm, return -ENODEV; #ifdef CONFIG_THERMAL - ret = thermal_zone_get_temp(cm->tzd_batt, (unsigned long *)temp); - if (!ret) - /* Calibrate temperature unit */ - *temp /= 100; -#else - ret = cm->fuel_gauge->get_property(cm->fuel_gauge, - POWER_SUPPLY_PROP_TEMP, - (union power_supply_propval *)temp); + if (cm->tzd_batt) { + ret = thermal_zone_get_temp(cm->tzd_batt, (unsigned long *)temp); + if (!ret) + /* Calibrate temperature unit */ + *temp /= 100; + } else #endif + { + /* if-else continued from CONFIG_THERMAL */ + ret = cm_get_battery_temperature_by_psy(cm, temp); + } + return ret; } @@ -827,6 +873,7 @@ static int charger_get_property(struct power_supply *psy, struct charger_manager *cm = container_of(psy, struct charger_manager, charger_psy); struct charger_desc *desc = cm->desc; + struct power_supply *fuel_gauge; int ret = 0; int uV; @@ -857,14 +904,20 @@ static int charger_get_property(struct power_supply *psy, ret = get_batt_uV(cm, &val->intval); break; case POWER_SUPPLY_PROP_CURRENT_NOW: - ret = cm->fuel_gauge->get_property(cm->fuel_gauge, + fuel_gauge = power_supply_get_by_name(cm->desc->psy_fuel_gauge); + if (!fuel_gauge) { + ret = -ENODEV; + break; + } + ret = fuel_gauge->get_property(fuel_gauge, POWER_SUPPLY_PROP_CURRENT_NOW, val); break; case POWER_SUPPLY_PROP_TEMP: case POWER_SUPPLY_PROP_TEMP_AMBIENT: return cm_get_battery_temperature(cm, &val->intval); case POWER_SUPPLY_PROP_CAPACITY: - if (!cm->fuel_gauge) { + fuel_gauge = power_supply_get_by_name(cm->desc->psy_fuel_gauge); + if (!fuel_gauge) { ret = -ENODEV; break; } @@ -875,7 +928,7 @@ static int charger_get_property(struct power_supply *psy, break; } - ret = cm->fuel_gauge->get_property(cm->fuel_gauge, + ret = fuel_gauge->get_property(fuel_gauge, POWER_SUPPLY_PROP_CAPACITY, val); if (ret) break; @@ -924,7 +977,14 @@ static int charger_get_property(struct power_supply *psy, break; case POWER_SUPPLY_PROP_CHARGE_NOW: if (is_charging(cm)) { - ret = cm->fuel_gauge->get_property(cm->fuel_gauge, + fuel_gauge = power_supply_get_by_name( + cm->desc->psy_fuel_gauge); + if (!fuel_gauge) { + ret = -ENODEV; + break; + } + + ret = fuel_gauge->get_property(fuel_gauge, POWER_SUPPLY_PROP_CHARGE_NOW, val); if (ret) { @@ -970,6 +1030,7 @@ static struct power_supply psy_default = { .properties = default_charger_props, .num_properties = ARRAY_SIZE(default_charger_props), .get_property = charger_get_property, + .no_thermal = true, }; /** @@ -1485,14 +1546,15 @@ err: return ret; } -static int cm_init_thermal_data(struct charger_manager *cm) +static int cm_init_thermal_data(struct charger_manager *cm, + struct power_supply *fuel_gauge) { struct charger_desc *desc = cm->desc; union power_supply_propval val; int ret; /* Verify whether fuel gauge provides battery temperature */ - ret = cm->fuel_gauge->get_property(cm->fuel_gauge, + ret = fuel_gauge->get_property(fuel_gauge, POWER_SUPPLY_PROP_TEMP, &val); if (!ret) { @@ -1502,8 +1564,6 @@ static int cm_init_thermal_data(struct charger_manager *cm) cm->desc->measure_battery_temp = true; } #ifdef CONFIG_THERMAL - cm->tzd_batt = cm->fuel_gauge->tzd; - if (ret && desc->thermal_zone) { cm->tzd_batt = thermal_zone_get_zone_by_name(desc->thermal_zone); @@ -1666,6 +1726,7 @@ static int charger_manager_probe(struct platform_device *pdev) int ret = 0, i = 0; int j = 0; union power_supply_propval val; + struct power_supply *fuel_gauge; if (g_desc && !rtc_dev && g_desc->rtc_name) { rtc_dev = rtc_class_open(g_desc->rtc_name); @@ -1729,23 +1790,20 @@ static int charger_manager_probe(struct platform_device *pdev) while (desc->psy_charger_stat[i]) i++; - cm->charger_stat = devm_kzalloc(&pdev->dev, - sizeof(struct power_supply *) * i, GFP_KERNEL); - if (!cm->charger_stat) - return -ENOMEM; - + /* Check if charger's supplies are present at probe */ for (i = 0; desc->psy_charger_stat[i]; i++) { - cm->charger_stat[i] = power_supply_get_by_name( - desc->psy_charger_stat[i]); - if (!cm->charger_stat[i]) { + struct power_supply *psy; + + psy = power_supply_get_by_name(desc->psy_charger_stat[i]); + if (!psy) { dev_err(&pdev->dev, "Cannot find power supply \"%s\"\n", desc->psy_charger_stat[i]); return -ENODEV; } } - cm->fuel_gauge = power_supply_get_by_name(desc->psy_fuel_gauge); - if (!cm->fuel_gauge) { + fuel_gauge = power_supply_get_by_name(desc->psy_fuel_gauge); + if (!fuel_gauge) { dev_err(&pdev->dev, "Cannot find power supply \"%s\"\n", desc->psy_fuel_gauge); return -ENODEV; @@ -1788,13 +1846,13 @@ static int charger_manager_probe(struct platform_device *pdev) cm->charger_psy.num_properties = psy_default.num_properties; /* Find which optional psy-properties are available */ - if (!cm->fuel_gauge->get_property(cm->fuel_gauge, + if (!fuel_gauge->get_property(fuel_gauge, POWER_SUPPLY_PROP_CHARGE_NOW, &val)) { cm->charger_psy.properties[cm->charger_psy.num_properties] = POWER_SUPPLY_PROP_CHARGE_NOW; cm->charger_psy.num_properties++; } - if (!cm->fuel_gauge->get_property(cm->fuel_gauge, + if (!fuel_gauge->get_property(fuel_gauge, POWER_SUPPLY_PROP_CURRENT_NOW, &val)) { cm->charger_psy.properties[cm->charger_psy.num_properties] = @@ -1802,7 +1860,7 @@ static int charger_manager_probe(struct platform_device *pdev) cm->charger_psy.num_properties++; } - ret = cm_init_thermal_data(cm); + ret = cm_init_thermal_data(cm, fuel_gauge); if (ret) { dev_err(&pdev->dev, "Failed to initialize thermal data\n"); cm->desc->measure_battery_temp = false; @@ -2066,8 +2124,8 @@ static bool find_power_supply(struct charger_manager *cm, int i; bool found = false; - for (i = 0; cm->charger_stat[i]; i++) { - if (psy == cm->charger_stat[i]) { + for (i = 0; cm->desc->psy_charger_stat[i]; i++) { + if (!strcmp(psy->name, cm->desc->psy_charger_stat[i])) { found = true; break; } |