diff options
Diffstat (limited to 'Documentation/ABI/testing')
9 files changed, 390 insertions, 5 deletions
diff --git a/Documentation/ABI/testing/sysfs-bus-counter b/Documentation/ABI/testing/sysfs-bus-counter new file mode 100644 index 000000000000..566bd99fe0a5 --- /dev/null +++ b/Documentation/ABI/testing/sysfs-bus-counter @@ -0,0 +1,230 @@ +What: /sys/bus/counter/devices/counterX/countY/count +KernelVersion: 5.2 +Contact: linux-iio@vger.kernel.org +Description: + Count data of Count Y represented as a string. + +What: /sys/bus/counter/devices/counterX/countY/ceiling +KernelVersion: 5.2 +Contact: linux-iio@vger.kernel.org +Description: + Count value ceiling for Count Y. This is the upper limit for the + respective counter. + +What: /sys/bus/counter/devices/counterX/countY/floor +KernelVersion: 5.2 +Contact: linux-iio@vger.kernel.org +Description: + Count value floor for Count Y. This is the lower limit for the + respective counter. + +What: /sys/bus/counter/devices/counterX/countY/count_mode +KernelVersion: 5.2 +Contact: linux-iio@vger.kernel.org +Description: + Count mode for channel Y. The ceiling and floor values for + Count Y are used by the count mode where required. The following + count modes are available: + + normal: + Counting is continuous in either direction. + + range limit: + An upper or lower limit is set, mimicking limit switches + in the mechanical counterpart. The upper limit is set to + the Count Y ceiling value, while the lower limit is set + to the Count Y floor value. The counter freezes at + count = ceiling when counting up, and at count = floor + when counting down. At either of these limits, the + counting is resumed only when the count direction is + reversed. + + non-recycle: + The counter is disabled whenever a counter overflow or + underflow takes place. The counter is re-enabled when a + new count value is loaded to the counter via a preset + operation or direct write. + + modulo-n: + A count value boundary is set between the Count Y floor + value and the Count Y ceiling value. The counter is + reset to the Count Y floor value at count = ceiling when + counting up, while the counter is set to the Count Y + ceiling value at count = floor when counting down; the + counter does not freeze at the boundary points, but + counts continuously throughout. + +What: /sys/bus/counter/devices/counterX/countY/count_mode_available +What: /sys/bus/counter/devices/counterX/countY/error_noise_available +What: /sys/bus/counter/devices/counterX/countY/function_available +What: /sys/bus/counter/devices/counterX/countY/signalZ_action_available +KernelVersion: 5.2 +Contact: linux-iio@vger.kernel.org +Description: + Discrete set of available values for the respective Count Y + configuration are listed in this file. Values are delimited by + newline characters. + +What: /sys/bus/counter/devices/counterX/countY/direction +KernelVersion: 5.2 +Contact: linux-iio@vger.kernel.org +Description: + Read-only attribute that indicates the count direction of Count + Y. Two count directions are available: forward and backward. + + Some counter devices are able to determine the direction of + their counting. For example, quadrature encoding counters can + determine the direction of movement by evaluating the leading + phase of the respective A and B quadrature encoding signals. + This attribute exposes such count directions. + +What: /sys/bus/counter/devices/counterX/countY/enable +KernelVersion: 5.2 +Contact: linux-iio@vger.kernel.org +Description: + Whether channel Y counter is enabled. Valid attribute values are + boolean. + + This attribute is intended to serve as a pause/unpause mechanism + for Count Y. Suppose a counter device is used to count the total + movement of a conveyor belt: this attribute allows an operator + to temporarily pause the counter, service the conveyor belt, + and then finally unpause the counter to continue where it had + left off. + +What: /sys/bus/counter/devices/counterX/countY/error_noise +KernelVersion: 5.2 +Contact: linux-iio@vger.kernel.org +Description: + Read-only attribute that indicates whether excessive noise is + present at the channel Y counter inputs. + +What: /sys/bus/counter/devices/counterX/countY/function +KernelVersion: 5.2 +Contact: linux-iio@vger.kernel.org +Description: + Count function mode of Count Y; count function evaluation is + triggered by conditions specified by the Count Y signalZ_action + attributes. The following count functions are available: + + increase: + Accumulated count is incremented. + + decrease: + Accumulated count is decremented. + + pulse-direction: + Rising edges on signal A updates the respective count. + The input level of signal B determines direction. + + quadrature x1 a: + If direction is forward, rising edges on quadrature pair + signal A updates the respective count; if the direction + is backward, falling edges on quadrature pair signal A + updates the respective count. Quadrature encoding + determines the direction. + + quadrature x1 b: + If direction is forward, rising edges on quadrature pair + signal B updates the respective count; if the direction + is backward, falling edges on quadrature pair signal B + updates the respective count. Quadrature encoding + determines the direction. + + quadrature x2 a: + Any state transition on quadrature pair signal A updates + the respective count. Quadrature encoding determines the + direction. + + quadrature x2 b: + Any state transition on quadrature pair signal B updates + the respective count. Quadrature encoding determines the + direction. + + quadrature x4: + Any state transition on either quadrature pair signals + updates the respective count. Quadrature encoding + determines the direction. + +What: /sys/bus/counter/devices/counterX/countY/name +KernelVersion: 5.2 +Contact: linux-iio@vger.kernel.org +Description: + Read-only attribute that indicates the device-specific name of + Count Y. If possible, this should match the name of the + respective channel as it appears in the device datasheet. + +What: /sys/bus/counter/devices/counterX/countY/preset +KernelVersion: 5.2 +Contact: linux-iio@vger.kernel.org +Description: + If the counter device supports preset registers -- registers + used to load counter channels to a set count upon device-defined + preset operation trigger events -- the preset count for channel + Y is provided by this attribute. + +What: /sys/bus/counter/devices/counterX/countY/preset_enable +KernelVersion: 5.2 +Contact: linux-iio@vger.kernel.org +Description: + Whether channel Y counter preset operation is enabled. Valid + attribute values are boolean. + +What: /sys/bus/counter/devices/counterX/countY/signalZ_action +KernelVersion: 5.2 +Contact: linux-iio@vger.kernel.org +Description: + Action mode of Count Y for Signal Z. This attribute indicates + the condition of Signal Z that triggers the count function + evaluation for Count Y. The following action modes are + available: + + none: + Signal does not trigger the count function. In + Pulse-Direction count function mode, this Signal is + evaluated as Direction. + + rising edge: + Low state transitions to high state. + + falling edge: + High state transitions to low state. + + both edges: + Any state transition. + +What: /sys/bus/counter/devices/counterX/name +KernelVersion: 5.2 +Contact: linux-iio@vger.kernel.org +Description: + Read-only attribute that indicates the device-specific name of + the Counter. This should match the name of the device as it + appears in its respective datasheet. + +What: /sys/bus/counter/devices/counterX/num_counts +KernelVersion: 5.2 +Contact: linux-iio@vger.kernel.org +Description: + Read-only attribute that indicates the total number of Counts + belonging to the Counter. + +What: /sys/bus/counter/devices/counterX/num_signals +KernelVersion: 5.2 +Contact: linux-iio@vger.kernel.org +Description: + Read-only attribute that indicates the total number of Signals + belonging to the Counter. + +What: /sys/bus/counter/devices/counterX/signalY/signal +KernelVersion: 5.2 +Contact: linux-iio@vger.kernel.org +Description: + Signal data of Signal Y represented as a string. + +What: /sys/bus/counter/devices/counterX/signalY/name +KernelVersion: 5.2 +Contact: linux-iio@vger.kernel.org +Description: + Read-only attribute that indicates the device-specific name of + Signal Y. If possible, this should match the name of the + respective signal as it appears in the device datasheet. diff --git a/Documentation/ABI/testing/sysfs-bus-counter-104-quad-8 b/Documentation/ABI/testing/sysfs-bus-counter-104-quad-8 new file mode 100644 index 000000000000..46b1f33b2fce --- /dev/null +++ b/Documentation/ABI/testing/sysfs-bus-counter-104-quad-8 @@ -0,0 +1,36 @@ +What: /sys/bus/counter/devices/counterX/signalY/index_polarity +KernelVersion: 5.2 +Contact: linux-iio@vger.kernel.org +Description: + Active level of index input Signal Y; irrelevant in + non-synchronous load mode. + +What: /sys/bus/counter/devices/counterX/signalY/index_polarity_available +What: /sys/bus/counter/devices/counterX/signalY/synchronous_mode_available +KernelVersion: 5.2 +Contact: linux-iio@vger.kernel.org +Description: + Discrete set of available values for the respective Signal Y + configuration are listed in this file. + +What: /sys/bus/counter/devices/counterX/signalY/synchronous_mode +KernelVersion: 5.2 +Contact: linux-iio@vger.kernel.org +Description: + Configure the counter associated with Signal Y for + non-synchronous or synchronous load mode. Synchronous load mode + cannot be selected in non-quadrature (Pulse-Direction) clock + mode. + + non-synchronous: + A logic low level is the active level at this index + input. The index function (as enabled via preset_enable) + is performed directly on the active level of the index + input. + + synchronous: + Intended for interfacing with encoder Index output in + quadrature clock mode. The active level is configured + via index_polarity. The index function (as enabled via + preset_enable) is performed synchronously with the + quadrature clock on the active level of the index input. diff --git a/Documentation/ABI/testing/sysfs-bus-counter-ftm-quaddec b/Documentation/ABI/testing/sysfs-bus-counter-ftm-quaddec new file mode 100644 index 000000000000..7d2e7b363467 --- /dev/null +++ b/Documentation/ABI/testing/sysfs-bus-counter-ftm-quaddec @@ -0,0 +1,16 @@ +What: /sys/bus/counter/devices/counterX/countY/prescaler_available +KernelVersion: 5.2 +Contact: linux-iio@vger.kernel.org +Description: + Discrete set of available values for the respective Count Y + configuration are listed in this file. Values are delimited by + newline characters. + +What: /sys/bus/counter/devices/counterX/countY/prescaler +KernelVersion: 5.2 +Contact: linux-iio@vger.kernel.org +Description: + Configure the prescaler value associated with Count Y. + On the FlexTimer, the counter clock source passes through a + prescaler (i.e. a counter). This acts like a clock + divider. diff --git a/Documentation/ABI/testing/sysfs-bus-iio b/Documentation/ABI/testing/sysfs-bus-iio index 864f8efd12e5..6aef7dbbde44 100644 --- a/Documentation/ABI/testing/sysfs-bus-iio +++ b/Documentation/ABI/testing/sysfs-bus-iio @@ -1656,6 +1656,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_countY_raw KernelVersion: 4.10 Contact: linux-iio@vger.kernel.org Description: + This interface is deprecated; please use the Counter subsystem. + Raw counter device counts from channel Y. For quadrature counters, multiplication by an available [Y]_scale results in the counts of a single quadrature signal phase from channel Y. @@ -1664,6 +1666,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_indexY_raw KernelVersion: 4.10 Contact: linux-iio@vger.kernel.org Description: + This interface is deprecated; please use the Counter subsystem. + Raw counter device index value from channel Y. This attribute provides an absolute positional reference (e.g. a pulse once per revolution) which may be used to home positional systems as @@ -1673,6 +1677,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_count_count_direction_available KernelVersion: 4.12 Contact: linux-iio@vger.kernel.org Description: + This interface is deprecated; please use the Counter subsystem. + A list of possible counting directions which are: - "up" : counter device is increasing. - "down": counter device is decreasing. @@ -1681,6 +1687,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_countY_count_direction KernelVersion: 4.12 Contact: linux-iio@vger.kernel.org Description: + This interface is deprecated; please use the Counter subsystem. + Raw counter device counters direction for channel Y. What: /sys/bus/iio/devices/iio:deviceX/in_phaseY_raw diff --git a/Documentation/ABI/testing/sysfs-bus-iio-counter-104-quad-8 b/Documentation/ABI/testing/sysfs-bus-iio-counter-104-quad-8 index 7fac2c268d9a..bac3d0d48b7b 100644 --- a/Documentation/ABI/testing/sysfs-bus-iio-counter-104-quad-8 +++ b/Documentation/ABI/testing/sysfs-bus-iio-counter-104-quad-8 @@ -6,6 +6,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_index_synchronous_mode_available KernelVersion: 4.10 Contact: linux-iio@vger.kernel.org Description: + This interface is deprecated; please use the Counter subsystem. + Discrete set of available values for the respective counter configuration are listed in this file. @@ -13,6 +15,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_countY_count_mode KernelVersion: 4.10 Contact: linux-iio@vger.kernel.org Description: + This interface is deprecated; please use the Counter subsystem. + Count mode for channel Y. Four count modes are available: normal, range limit, non-recycle, and modulo-n. The preset value for channel Y is used by the count mode where required. @@ -47,6 +51,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_countY_noise_error KernelVersion: 4.10 Contact: linux-iio@vger.kernel.org Description: + This interface is deprecated; please use the Counter subsystem. + Read-only attribute that indicates whether excessive noise is present at the channel Y count inputs in quadrature clock mode; irrelevant in non-quadrature clock mode. @@ -55,6 +61,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_countY_preset KernelVersion: 4.10 Contact: linux-iio@vger.kernel.org Description: + This interface is deprecated; please use the Counter subsystem. + If the counter device supports preset registers, the preset count for channel Y is provided by this attribute. @@ -62,6 +70,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_countY_quadrature_mode KernelVersion: 4.10 Contact: linux-iio@vger.kernel.org Description: + This interface is deprecated; please use the Counter subsystem. + Configure channel Y counter for non-quadrature or quadrature clock mode. Selecting non-quadrature clock mode will disable synchronous load mode. In quadrature clock mode, the channel Y @@ -83,6 +93,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_countY_set_to_preset_on_index KernelVersion: 4.10 Contact: linux-iio@vger.kernel.org Description: + This interface is deprecated; please use the Counter subsystem. + Whether to set channel Y counter with channel Y preset value when channel Y index input is active, or continuously count. Valid attribute values are boolean. @@ -91,6 +103,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_indexY_index_polarity KernelVersion: 4.10 Contact: linux-iio@vger.kernel.org Description: + This interface is deprecated; please use the Counter subsystem. + Active level of channel Y index input; irrelevant in non-synchronous load mode. @@ -98,6 +112,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_indexY_synchronous_mode KernelVersion: 4.10 Contact: linux-iio@vger.kernel.org Description: + This interface is deprecated; please use the Counter subsystem. + Configure channel Y counter for non-synchronous or synchronous load mode. Synchronous load mode cannot be selected in non-quadrature clock mode. diff --git a/Documentation/ABI/testing/sysfs-bus-iio-impedance-analyzer-ad5933 b/Documentation/ABI/testing/sysfs-bus-iio-impedance-analyzer-ad5933 new file mode 100644 index 000000000000..0e86747c67f8 --- /dev/null +++ b/Documentation/ABI/testing/sysfs-bus-iio-impedance-analyzer-ad5933 @@ -0,0 +1,35 @@ +What: /sys/bus/iio/devices/iio:deviceX/out_altvoltageY_frequency_start +Date: March 2019 +KernelVersion: 3.1.0 +Contact: linux-iio@vger.kernel.org +Description: + Frequency sweep start frequency in Hz. + +What: /sys/bus/iio/devices/iio:deviceX/out_altvoltageY_frequency_increment +Date: March 2019 +KernelVersion: 3.1.0 +Contact: linux-iio@vger.kernel.org +Description: + Frequency increment in Hz (step size) between consecutive + frequency points along the sweep. + +What: /sys/bus/iio/devices/iio:deviceX/out_altvoltageY_frequency_points +Date: March 2019 +KernelVersion: 3.1.0 +Contact: linux-iio@vger.kernel.org +Description: + Number of frequency points (steps) in the frequency sweep. + This value, in conjunction with the + out_altvoltageY_frequency_start and the + out_altvoltageY_frequency_increment, determines the frequency + sweep range for the sweep operation. + +What: /sys/bus/iio/devices/iio:deviceX/out_altvoltageY_settling_cycles +Date: March 2019 +KernelVersion: 3.1.0 +Contact: linux-iio@vger.kernel.org +Description: + Number of output excitation cycles (settling time cycles) + that are allowed to pass through the unknown impedance, + after each frequency increment, and before the ADC is triggered + to perform a conversion sequence of the response signal. diff --git a/Documentation/ABI/testing/sysfs-bus-iio-sps30 b/Documentation/ABI/testing/sysfs-bus-iio-sps30 index 143df8e89d08..06e1c272537b 100644 --- a/Documentation/ABI/testing/sysfs-bus-iio-sps30 +++ b/Documentation/ABI/testing/sysfs-bus-iio-sps30 @@ -1,6 +1,6 @@ What: /sys/bus/iio/devices/iio:deviceX/start_cleaning Date: December 2018 -KernelVersion: 4.22 +KernelVersion: 5.0 Contact: linux-iio@vger.kernel.org Description: Writing 1 starts sensor self cleaning. Internal fan accelerates diff --git a/Documentation/ABI/testing/sysfs-bus-iio-temperature-max31856 b/Documentation/ABI/testing/sysfs-bus-iio-temperature-max31856 new file mode 100644 index 000000000000..3b3509a3ef2f --- /dev/null +++ b/Documentation/ABI/testing/sysfs-bus-iio-temperature-max31856 @@ -0,0 +1,24 @@ +What: /sys/bus/iio/devices/iio:deviceX/fault_oc +KernelVersion: 5.1 +Contact: linux-iio@vger.kernel.org +Description: + Open-circuit fault. The detection of open-circuit faults, + such as those caused by broken thermocouple wires. + Reading returns either '1' or '0'. + '1' = An open circuit such as broken thermocouple wires + has been detected. + '0' = No open circuit or broken thermocouple wires are detected + +What: /sys/bus/iio/devices/iio:deviceX/fault_ovuv +KernelVersion: 5.1 +Contact: linux-iio@vger.kernel.org +Description: + Overvoltage or Undervoltage Input Fault. The internal circuitry + is protected from excessive voltages applied to the thermocouple + cables by integrated MOSFETs at the T+ and T- inputs, and the + BIAS output. These MOSFETs turn off when the input voltage is + negative or greater than VDD. + Reading returns either '1' or '0'. + '1' = The input voltage is negative or greater than VDD. + '0' = The input voltage is positive and less than VDD (normal + state). diff --git a/Documentation/ABI/testing/sysfs-devices-system-cpu b/Documentation/ABI/testing/sysfs-devices-system-cpu index 9605dbd4b5b5..4fb76c0e8d30 100644 --- a/Documentation/ABI/testing/sysfs-devices-system-cpu +++ b/Documentation/ABI/testing/sysfs-devices-system-cpu @@ -511,10 +511,30 @@ Description: Control Symetric Multi Threading (SMT) control: Read/write interface to control SMT. Possible values: - "on" SMT is enabled - "off" SMT is disabled - "forceoff" SMT is force disabled. Cannot be changed. - "notsupported" SMT is not supported by the CPU + "on" SMT is enabled + "off" SMT is disabled + "forceoff" SMT is force disabled. Cannot be changed. + "notsupported" SMT is not supported by the CPU + "notimplemented" SMT runtime toggling is not + implemented for the architecture If control status is "forceoff" or "notsupported" writes are rejected. + +What: /sys/devices/system/cpu/cpu#/power/energy_perf_bias +Date: March 2019 +Contact: linux-pm@vger.kernel.org +Description: Intel Energy and Performance Bias Hint (EPB) + + EPB for the given CPU in a sliding scale 0 - 15, where a value + of 0 corresponds to a hint preference for highest performance + and a value of 15 corresponds to the maximum energy savings. + + In order to change the EPB value for the CPU, write either + a number in the 0 - 15 sliding scale above, or one of the + strings: "performance", "balance-performance", "normal", + "balance-power", "power" (that represent values reflected by + their meaning), to this attribute. + + This attribute is present for all online CPUs supporting the + Intel EPB feature. |