@@ -92,6 +92,18 @@ Description:
is required is a consistent labeling. Units after application
of scale and offset are millivolts.
+What: /sys/bus/iio/devices/iio:deviceX/in_currentY_raw
+What: /sys/bus/iio/devices/iio:deviceX/in_currentY_supply_raw
+KernelVersion: 3.17
+Contact: linux-iio@vger.kernel.org
+Description:
+ Raw (unscaled no bias removal etc.) current measurement from
+ channel Y. In special cases where the channel does not
+ correspond to externally available input one of the named
+ versions may be used. The number must always be specified and
+ unique to allow association with event codes. Units after
+ application of scale and offset are milliamps.
+
What: /sys/bus/iio/devices/iio:deviceX/in_capacitanceY_raw
KernelVersion: 3.2
Contact: linux-iio@vger.kernel.org
@@ -234,6 +246,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_accel_y_offset
What: /sys/bus/iio/devices/iio:deviceX/in_accel_z_offset
What: /sys/bus/iio/devices/iio:deviceX/in_voltageY_offset
What: /sys/bus/iio/devices/iio:deviceX/in_voltage_offset
+What: /sys/bus/iio/devices/iio:deviceX/in_currentY_offset
+What: /sys/bus/iio/devices/iio:deviceX/in_current_offset
What: /sys/bus/iio/devices/iio:deviceX/in_tempY_offset
What: /sys/bus/iio/devices/iio:deviceX/in_temp_offset
What: /sys/bus/iio/devices/iio:deviceX/in_pressureY_offset
@@ -262,6 +276,9 @@ What: /sys/bus/iio/devices/iio:deviceX/in_voltage_scale
What: /sys/bus/iio/devices/iio:deviceX/in_voltage-voltage_scale
What: /sys/bus/iio/devices/iio:deviceX/out_voltageY_scale
What: /sys/bus/iio/devices/iio:deviceX/out_altvoltageY_scale
+What: /sys/bus/iio/devices/iio:deviceX/in_currentY_scale
+What: /sys/bus/iio/devices/iio:deviceX/in_currentY_supply_scale
+What: /sys/bus/iio/devices/iio:deviceX/in_current_scale
What: /sys/bus/iio/devices/iio:deviceX/in_accel_scale
What: /sys/bus/iio/devices/iio:deviceX/in_accel_peak_scale
What: /sys/bus/iio/devices/iio:deviceX/in_anglvel_scale
@@ -323,6 +340,14 @@ Description:
production inaccuracies). If shared across all channels,
<type>_calibscale is used.
+What: /sys/bus/iio/devices/iio:deviceX/in_steps_calibheight
+KernelVersion: 3.19
+Contact: linux-iio@vger.kernel.org
+Description:
+ Height of the user (in centimeters) used by some pedometers
+ to compute the stride length, distance, speed and activity
+ type.
+
What: /sys/bus/iio/devices/iio:deviceX/in_accel_scale_available
What: /sys/.../iio:deviceX/in_voltageX_scale_available
What: /sys/.../iio:deviceX/in_voltage-voltage_scale_available
@@ -790,6 +815,40 @@ Description:
met before an event is generated. If direction is not
specified then this period applies to both directions.
+What: /sys/.../events/in_activity_still_thresh_rising_en
+What: /sys/.../events/in_activity_still_thresh_falling_en
+What: /sys/.../events/in_activity_walking_thresh_rising_en
+What: /sys/.../events/in_activity_walking_thresh_falling_en
+What: /sys/.../events/in_activity_jogging_thresh_rising_en
+What: /sys/.../events/in_activity_jogging_thresh_falling_en
+What: /sys/.../events/in_activity_running_thresh_rising_en
+What: /sys/.../events/in_activity_running_thresh_falling_en
+KernelVersion: 3.19
+Contact: linux-iio@vger.kernel.org
+Description:
+ Enables or disables activitity events. Depending on direction
+ an event is generated when sensor ENTERS or LEAVES a given state.
+
+What: /sys/.../events/in_activity_still_thresh_rising_value
+What: /sys/.../events/in_activity_still_thresh_falling_value
+What: /sys/.../events/in_activity_walking_thresh_rising_value
+What: /sys/.../events/in_activity_walking_thresh_falling_value
+What: /sys/.../events/in_activity_jogging_thresh_rising_value
+What: /sys/.../events/in_activity_jogging_thresh_falling_value
+What: /sys/.../events/in_activity_running_thresh_rising_value
+What: /sys/.../events/in_activity_running_thresh_falling_value
+KernelVersion: 3.19
+Contact: linux-iio@vger.kernel.org
+Description:
+ Confidence value (in units as percentage) to be used
+ for deciding when an event should be generated. E.g for
+ running: If the confidence value reported by the sensor
+ is greater than in_activity_running_thresh_rising_value
+ then the sensor ENTERS running state. Conversely, if the
+ confidence value reported by the sensor is lower than
+ in_activity_running_thresh_falling_value then the sensor
+ is LEAVING running state.
+
What: /sys/.../iio:deviceX/events/in_accel_mag_en
What: /sys/.../iio:deviceX/events/in_accel_mag_rising_en
What: /sys/.../iio:deviceX/events/in_accel_mag_falling_en
@@ -822,6 +881,13 @@ Description:
number or direction is not specified, applies to all channels of
this type.
+What: /sys/.../events/in_steps_instance_en
+KernelVersion: 3.19
+Contact: linux-iio@vger.kernel.org
+Description:
+ Enables or disables step detection. Each time the user takes a step an
+ event of this type will be generated.
+
What: /sys/bus/iio/devices/iio:deviceX/trigger/current_trigger
KernelVersion: 2.6.35
Contact: linux-iio@vger.kernel.org
@@ -956,6 +1022,16 @@ Description:
and the relevant _type attributes to establish the data storage
format.
+What: /sys/.../iio:deviceX/in_activity_still_input
+What: /sys/.../iio:deviceX/in_activity_walking_input
+What: /sys/.../iio:deviceX/in_activity_jogging_input
+What: /sys/.../iio:deviceX/in_activity_running_input
+KernelVersion: 3.19
+Contact: linux-iio@vger.kernel.org
+Description:
+ This attribute is used to read the confidence for an activity
+ expressed in units as percentage.
+
What: /sys/.../iio:deviceX/in_anglvel_z_quadrature_correction_raw
KernelVersion: 2.6.38
Contact: linux-iio@vger.kernel.org
@@ -992,7 +1068,9 @@ Description:
reflectivity of infrared or ultrasound emitted.
Often these sensors are unit less and as such conversion
to SI units is not possible. Where it is, the units should
- be meters.
+ be meters. If such a conversion is not possible, the reported
+ values should behave in the same way as a distance, i.e. lower
+ values indicate something is closer to the sensor.
What: /sys/.../iio:deviceX/in_illuminanceY_input
What: /sys/.../iio:deviceX/in_illuminanceY_raw
@@ -1051,3 +1129,18 @@ Description:
after application of scale and offset. If no offset or scale is
present, output should be considered as processed with the
unit in milliamps.
+
+What: /sys/.../iio:deviceX/in_steps_en
+KernelVersion: 3.19
+Contact: linux-iio@vger.kernel.org
+Description:
+ Activates the step counter. After activation, the number of steps
+ taken by the user will be counted in hardware and exported through
+ in_steps_input.
+
+What: /sys/.../iio:deviceX/in_steps_input
+KernelVersion: 3.19
+Contact: linux-iio@vger.kernel.org
+Description:
+ This attribute is used to read the number of steps taken by the user