summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
-rw-r--r--drivers/thermal/cpu_cooling.c5
-rw-r--r--drivers/thermal/db8500_cpufreq_cooling.c5
-rw-r--r--drivers/thermal/imx_thermal.c5
-rw-r--r--drivers/thermal/samsung/exynos_thermal_common.c8
-rw-r--r--drivers/thermal/samsung/exynos_tmu.c5
-rw-r--r--drivers/thermal/ti-soc-thermal/ti-thermal-common.c6
6 files changed, 14 insertions, 20 deletions
diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c
index ad09e51ffae4..f98a763af2f5 100644
--- a/drivers/thermal/cpu_cooling.c
+++ b/drivers/thermal/cpu_cooling.c
@@ -443,6 +443,11 @@ __cpufreq_cooling_register(struct device_node *np,
int ret = 0, i;
struct cpufreq_policy policy;
+ if (!cpufreq_frequency_get_table(cpumask_first(clip_cpus))) {
+ pr_debug("%s: CPUFreq table not found\n", __func__);
+ return ERR_PTR(-EPROBE_DEFER);
+ }
+
/* Verify that all the clip cpus have same freq_min, freq_max limit */
for_each_cpu(i, clip_cpus) {
/* continue if cpufreq policy not found and not return error */
diff --git a/drivers/thermal/db8500_cpufreq_cooling.c b/drivers/thermal/db8500_cpufreq_cooling.c
index 786d19263ab0..1ac7ec651c3f 100644
--- a/drivers/thermal/db8500_cpufreq_cooling.c
+++ b/drivers/thermal/db8500_cpufreq_cooling.c
@@ -18,7 +18,6 @@
*/
#include <linux/cpu_cooling.h>
-#include <linux/cpufreq.h>
#include <linux/err.h>
#include <linux/module.h>
#include <linux/of.h>
@@ -30,10 +29,6 @@ static int db8500_cpufreq_cooling_probe(struct platform_device *pdev)
struct thermal_cooling_device *cdev;
struct cpumask mask_val;
- /* make sure cpufreq driver has been initialized */
- if (!cpufreq_frequency_get_table(0))
- return -EPROBE_DEFER;
-
cpumask_set_cpu(0, &mask_val);
cdev = cpufreq_cooling_register(&mask_val);
diff --git a/drivers/thermal/imx_thermal.c b/drivers/thermal/imx_thermal.c
index 5a1f1070b702..16405b4848f1 100644
--- a/drivers/thermal/imx_thermal.c
+++ b/drivers/thermal/imx_thermal.c
@@ -9,7 +9,6 @@
#include <linux/clk.h>
#include <linux/cpu_cooling.h>
-#include <linux/cpufreq.h>
#include <linux/delay.h>
#include <linux/device.h>
#include <linux/init.h>
@@ -459,10 +458,6 @@ static int imx_thermal_probe(struct platform_device *pdev)
int measure_freq;
int ret;
- if (!cpufreq_get_current_driver()) {
- dev_dbg(&pdev->dev, "no cpufreq driver!");
- return -EPROBE_DEFER;
- }
data = devm_kzalloc(&pdev->dev, sizeof(*data), GFP_KERNEL);
if (!data)
return -ENOMEM;
diff --git a/drivers/thermal/samsung/exynos_thermal_common.c b/drivers/thermal/samsung/exynos_thermal_common.c
index b6be572704a4..50a1f17c6221 100644
--- a/drivers/thermal/samsung/exynos_thermal_common.c
+++ b/drivers/thermal/samsung/exynos_thermal_common.c
@@ -371,9 +371,11 @@ int exynos_register_thermal(struct thermal_sensor_conf *sensor_conf)
th_zone->cool_dev[th_zone->cool_dev_size] =
cpufreq_cooling_register(&mask_val);
if (IS_ERR(th_zone->cool_dev[th_zone->cool_dev_size])) {
- dev_err(sensor_conf->dev,
- "Failed to register cpufreq cooling device\n");
- ret = -EINVAL;
+ ret = PTR_ERR(th_zone->cool_dev[th_zone->cool_dev_size]);
+ if (ret != -EPROBE_DEFER)
+ dev_err(sensor_conf->dev,
+ "Failed to register cpufreq cooling device: %d\n",
+ ret);
goto err_unregister;
}
th_zone->cool_dev_size++;
diff --git a/drivers/thermal/samsung/exynos_tmu.c b/drivers/thermal/samsung/exynos_tmu.c
index 49c09243fd38..2afca9bf40d5 100644
--- a/drivers/thermal/samsung/exynos_tmu.c
+++ b/drivers/thermal/samsung/exynos_tmu.c
@@ -683,7 +683,10 @@ static int exynos_tmu_probe(struct platform_device *pdev)
/* Register the sensor with thermal management interface */
ret = exynos_register_thermal(sensor_conf);
if (ret) {
- dev_err(&pdev->dev, "Failed to register thermal interface\n");
+ if (ret != -EPROBE_DEFER)
+ dev_err(&pdev->dev,
+ "Failed to register thermal interface: %d\n",
+ ret);
goto err_clk;
}
data->reg_conf = sensor_conf;
diff --git a/drivers/thermal/ti-soc-thermal/ti-thermal-common.c b/drivers/thermal/ti-soc-thermal/ti-thermal-common.c
index 9eec26dc0448..5f07d7e3a198 100644
--- a/drivers/thermal/ti-soc-thermal/ti-thermal-common.c
+++ b/drivers/thermal/ti-soc-thermal/ti-thermal-common.c
@@ -28,7 +28,6 @@
#include <linux/kernel.h>
#include <linux/workqueue.h>
#include <linux/thermal.h>
-#include <linux/cpufreq.h>
#include <linux/cpumask.h>
#include <linux/cpu_cooling.h>
#include <linux/of.h>
@@ -403,11 +402,6 @@ int ti_thermal_register_cpu_cooling(struct ti_bandgap *bgp, int id)
if (!data)
return -EINVAL;
- if (!cpufreq_get_current_driver()) {
- dev_dbg(bgp->dev, "no cpufreq driver yet\n");
- return -EPROBE_DEFER;
- }
-
/* Register cooling device */
data->cool_dev = cpufreq_cooling_register(cpu_present_mask);
if (IS_ERR(data->cool_dev)) {