can: m_can: add device tree binding documentation
add M_CAN device tree binding documentation Cc: Wolfgang Grandegger <wg@grandegger.com> Cc: Marc Kleine-Budde <mkl@pengutronix.de> Cc: Mark Rutland <mark.rutland@arm.com> Cc: Oliver Hartkopp <socketcan@hartkopp.net> Cc: Varka Bhadram <varkabhadram@gmail.com> Signed-off-by: Dong Aisheng <b29396@freescale.com> Reviewed-by: Varka Bhadram <varkabhadram@gmail.com> Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
Diffstat (limited to 'Documentation/devicetree/bindings/net')
-rw-r--r--Documentation/devicetree/bindings/net/can/m_can.txt67
1 files changed, 67 insertions, 0 deletions
diff --git a/Documentation/devicetree/bindings/net/can/m_can.txt b/Documentation/devicetree/bindings/net/can/m_can.txt
new file mode 100644
index 000000000000..9e331777c203
--- /dev/null
+++ b/Documentation/devicetree/bindings/net/can/m_can.txt
@@ -0,0 +1,67 @@
+Bosch MCAN controller Device Tree Bindings
+-------------------------------------------------
+
+Required properties:
+- compatible : Should be "bosch,m_can" for M_CAN controllers
+- reg : physical base address and size of the M_CAN
+ registers map and Message RAM
+- reg-names : Should be "m_can" and "message_ram"
+- interrupts : Should be the interrupt number of M_CAN interrupt
+ line 0 and line 1, could be same if sharing
+ the same interrupt.
+- interrupt-names : Should contain "int0" and "int1"
+- clocks : Clocks used by controller, should be host clock
+ and CAN clock.
+- clock-names : Should contain "hclk" and "cclk"
+- pinctrl-<n> : Pinctrl states as described in bindings/pinctrl/pinctrl-bindings.txt
+- pinctrl-names : Names corresponding to the numbered pinctrl states
+- bosch,mram-cfg : Message RAM configuration data.
+ Multiple M_CAN instances can share the same Message
+ RAM and each element(e.g Rx FIFO or Tx Buffer and etc)
+ number in Message RAM is also configurable,
+ so this property is telling driver how the shared or
+ private Message RAM are used by this M_CAN controller.
+
+ The format should be as follows:
+ <offset sidf_elems xidf_elems rxf0_elems rxf1_elems
+ rxb_elems txe_elems txb_elems>
+ The 'offset' is an address offset of the Message RAM
+ where the following elements start from. This is
+ usually set to 0x0 if you're using a private Message
+ RAM. The remain cells are used to specify how many
+ elements are used for each FIFO/Buffer.
+
+ M_CAN includes the following elements according to user manual:
+ 11-bit Filter 0-128 elements / 0-128 words
+ 29-bit Filter 0-64 elements / 0-128 words
+ Rx FIFO 0 0-64 elements / 0-1152 words
+ Rx FIFO 1 0-64 elements / 0-1152 words
+ Rx Buffers 0-64 elements / 0-1152 words
+ Tx Event FIFO 0-32 elements / 0-64 words
+ Tx Buffers 0-32 elements / 0-576 words
+
+ Please refer to 2.4.1 Message RAM Configuration in
+ Bosch M_CAN user manual for details.
+
+Example:
+SoC dtsi:
+m_can1: can@020e8000 {
+ compatible = "bosch,m_can";
+ reg = <0x020e8000 0x4000>, <0x02298000 0x4000>;
+ reg-names = "m_can", "message_ram";
+ interrupts = <0 114 0x04>,
+ <0 114 0x04>;
+ interrupt-names = "int0", "int1";
+ clocks = <&clks IMX6SX_CLK_CANFD>,
+ <&clks IMX6SX_CLK_CANFD>;
+ clock-names = "hclk", "cclk";
+ bosch,mram-cfg = <0x0 0 0 32 0 0 0 1>;
+ status = "disabled";
+};
+
+Board dts:
+&m_can1 {
+ pinctrl-names = "default";
+ pinctrl-0 = <&pinctrl_m_can1>;
+ status = "enabled";
+};