summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorCédric Le Goater <clg@kaod.org>2020-06-08 13:57:14 +0200
committerPaul Mackerras <paulus@ozlabs.org>2020-07-21 15:38:03 +1000
commite55f4d5898a9855350834535037f62732bbd320a (patch)
tree9c4654f6122b302c86099ab3dffb5b7898bc6a61
parent4cb4ade19b4219af8f5cda9313dd99b0004c8b3c (diff)
KVM: PPC: Book3S HV: Increase KVMPPC_NR_LPIDS on POWER8 and POWER9
POWER8 and POWER9 have 12-bit LPIDs. Change LPID_RSVD to support up to (4096 - 2) guests on these processors. POWER7 is kept the same with a limitation of (1024 - 2), but it might be time to drop KVM support for POWER7. Tested with 2048 guests * 4 vCPUs on a witherspoon system with 512G RAM and a bit of swap. Signed-off-by: Cédric Le Goater <clg@kaod.org> Signed-off-by: Paul Mackerras <paulus@ozlabs.org>
-rw-r--r--arch/powerpc/include/asm/reg.h3
-rw-r--r--arch/powerpc/kvm/book3s_64_mmu_hv.c8
2 files changed, 8 insertions, 3 deletions
diff --git a/arch/powerpc/include/asm/reg.h b/arch/powerpc/include/asm/reg.h
index 28311e52d7e8..caef0483e9bb 100644
--- a/arch/powerpc/include/asm/reg.h
+++ b/arch/powerpc/include/asm/reg.h
@@ -473,7 +473,8 @@
#ifndef SPRN_LPID
#define SPRN_LPID 0x13F /* Logical Partition Identifier */
#endif
-#define LPID_RSVD 0x3ff /* Reserved LPID for partn switching */
+#define LPID_RSVD_POWER7 0x3ff /* Reserved LPID for partn switching */
+#define LPID_RSVD 0xfff /* Reserved LPID for partn switching */
#define SPRN_HMER 0x150 /* Hypervisor maintenance exception reg */
#define HMER_DEBUG_TRIG (1ul << (63 - 17)) /* Debug trigger */
#define SPRN_HMEER 0x151 /* Hyp maintenance exception enable reg */
diff --git a/arch/powerpc/kvm/book3s_64_mmu_hv.c b/arch/powerpc/kvm/book3s_64_mmu_hv.c
index 7c5a1812a1c3..38ea396a23d6 100644
--- a/arch/powerpc/kvm/book3s_64_mmu_hv.c
+++ b/arch/powerpc/kvm/book3s_64_mmu_hv.c
@@ -260,11 +260,15 @@ int kvmppc_mmu_hv_init(void)
if (!mmu_has_feature(MMU_FTR_LOCKLESS_TLBIE))
return -EINVAL;
- /* POWER7 has 10-bit LPIDs (12-bit in POWER8) */
host_lpid = 0;
if (cpu_has_feature(CPU_FTR_HVMODE))
host_lpid = mfspr(SPRN_LPID);
- rsvd_lpid = LPID_RSVD;
+
+ /* POWER8 and above have 12-bit LPIDs (10-bit in POWER7) */
+ if (cpu_has_feature(CPU_FTR_ARCH_207S))
+ rsvd_lpid = LPID_RSVD;
+ else
+ rsvd_lpid = LPID_RSVD_POWER7;
kvmppc_init_lpid(rsvd_lpid + 1);